Literature DB >> 23278290

Influence of temporal variation in wall shear stress on intima-media thickening in arteriovenous fistulae.

Ehsan Rajabi-Jagahrgh1, Mahesh K Krishnamoorthy, Yang Wang, Ann Choe, Prabir Roy-Chaudhury, Rupak K Banerjee.   

Abstract

Arteriovenous fistula (AVF) failure is mainly due to venous stenosis characterized by significant amount of intima-media thickening (IMT), probably in the presence of negative (inward) remodeling. Our hypothesis is that the longitudinal changes in wall shear stress (WSS) within different configurations of AVF can influence remodeling factors (changes in luminal diameter (ΔDh ) and IMT) during its maturation process. Dh is an equivalent diameter for a noncircular conduit. A total of six AVFs with curved (C-AVF; n = 3) and straight (S-AVF; n = 3) configurations were created between the femoral artery and vein of three pigs, bilaterally. CT scans and ultrasounds were utilized to calculate local WSS at 2D (D: days), 7D, and 28D postsurgery. For each AVF, IMT was measured at four regions along the vein using morphometric analyses. At these regions, repeated measurements of WSS and luminal diameter of each AVF were obtained over time. The ΔD(h) between 7D and 28D was significantly larger for C-AVF than for S-AVF (2.27 ± 0.67 mm vs. 0.02 ± 0.55 mm; p < 0.05). Also, at 28D the amount of IMT in C-AVF (77.46 ± 7.10 units) was significantly greater (p < 0.05) when compared with S-AVF (53.71 ± 8.23 units). These structural changes were accompanied by significantly different gradients of WSS over time (τ') for C-AVF (-0.56 ± 0.60 dyne/cm(2)/day) in comparison with S-AVF (0.71 ± 0.39 dyne/cm(2)/day). Negative τ' for C-AVF corresponded to reduction in WSS level over time resulting in a physiological level of WSS at 28D (4.08 ± 5.08 dyne/cm(2)). In contrast, a positive τ' for S-AVF was associated with the increase in WSS levels over time causing high levels of WSS at 28D (36.68 ± 5.32 dyne/cm(2)). The decrease in WSS levels for the C-AVF over time was associated with outward remodeling of the venous wall (favorable to maturation). In contrast, for S-AVF, the increase in WSS levels over time was associated with inward remodeling and subsequently, venous stenosis. Thus, temporal gradients of WSS, which could be altered by the surgical configuration of AVF, may provide important information on the remodeling behavior of AVFs. Identification of an optimal AVF configuration, which results in a temporal decrease in WSS and an outward remodeling of the venous wall, may reduce AVF maturation failure. Published 2012. This article is a U.S. Government work and is in the public domain in the USA.

Entities:  

Mesh:

Year:  2012        PMID: 23278290     DOI: 10.1111/sdi.12045

Source DB:  PubMed          Journal:  Semin Dial        ISSN: 0894-0959            Impact factor:   3.455


  10 in total

1.  Design of a cone-and-plate device for controlled realistic shear stress stimulation on endothelial cell monolayers.

Authors:  Marco Franzoni; Irene Cattaneo; Bogdan Ene-Iordache; Alberto Oldani; Paolo Righettini; Andrea Remuzzi
Journal:  Cytotechnology       Date:  2016-01-11       Impact factor: 2.058

Review 2.  Combined functional and anatomical diagnostic endpoints for assessing arteriovenous fistula dysfunction.

Authors:  Ehsan Rajabi-Jaghargh; Rupak K Banerjee
Journal:  World J Nephrol       Date:  2015-02-06

3.  CD4(+) lymphocytes improve venous blood flow in experimental arteriovenous fistulae.

Authors:  Juan C Duque; Laisel Martinez; Annia Mesa; Yuntao Wei; Marwan Tabbara; Loay H Salman; Roberto I Vazquez-Padron
Journal:  Surgery       Date:  2015-05-18       Impact factor: 3.982

Review 4.  Computational Fluid Dynamics of Vascular Disease in Animal Models.

Authors:  Andrea Acuna; Alycia G Berman; Frederick W Damen; Brett A Meyers; Amelia R Adelsperger; Kelsey C Bayer; Melissa C Brindise; Brittani Bungart; Alexander M Kiel; Rachel A Morrison; Joseph C Muskat; Kelsey M Wasilczuk; Yi Wen; Jiacheng Zhang; Patrick Zito; Craig J Goergen
Journal:  J Biomech Eng       Date:  2018-08-01       Impact factor: 2.097

Review 5.  Challenges and novel therapies for vascular access in haemodialysis.

Authors:  Jeffrey H Lawson; Laura E Niklason; Prabir Roy-Chaudhury
Journal:  Nat Rev Nephrol       Date:  2020-08-24       Impact factor: 28.314

6.  Mobilization of Endothelial Progenitor Cells Following Creation of Arteriovenous Access in Patients with End-Stage Renal Disease.

Authors:  Jun-Neng Roan; Chwan-Yau Luo; Mang-Da Tsai; I-Shuan Wu; Shih-Wei Chang; Chien-Chi Huang; Yau-Sheng Tsai; Chen-Fuh Lam
Journal:  Acta Cardiol Sin       Date:  2015-01       Impact factor: 2.672

7.  Hemodynamic Shear Stress and Endothelial Dysfunction in Hemodialysis Access.

Authors:  Michelle K Fitts; Daniel B Pike; Kasey Anderson; Yan-Ting Shiu
Journal:  Open Urol Nephrol J       Date:  2014

8.  1α,25-Dihydroxyvitamin D3 Encapsulated in Nanoparticles Prevents Venous Neointimal Hyperplasia and Stenosis in Porcine Arteriovenous Fistulas.

Authors:  Avishek K Singh; Chuanqi Cai; Sreenivasulu Kilari; Chenglei Zhao; Michael L Simeon; Edwin Takahashi; Elazer R Edelman; Hyunjoon Joon Kong; Thanila Macedo; Ravinder J Singh; Matthew W Urban; Rajiv Kumar; Sanjay Misra
Journal:  J Am Soc Nephrol       Date:  2021-02-24       Impact factor: 10.121

9.  Computationally guided in-vitro vascular growth model reveals causal link between flow oscillations and disorganized neotissue.

Authors:  Eline E van Haaften; Sjeng Quicken; Wouter Huberts; Carlijn V C Bouten; Nicholas A Kurniawan
Journal:  Commun Biol       Date:  2021-05-10

Review 10.  The Role of Shear Stress in Arteriovenous Fistula Maturation and Failure: A Systematic Review.

Authors:  Leonard D Browne; Khalid Bashar; Philip Griffin; Eamon G Kavanagh; Stewart R Walsh; Michael T Walsh
Journal:  PLoS One       Date:  2015-12-30       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.