An isocenter detection and verification device for use in proton therapy.

H Fuse1, T Sakae, T Terunuma, M Sato, S Aoki.   

Abstract

We developed a new device for isocenter detection and verification for use in proton therapy. This device can be used to confirm the isocenters of a room laser, a digital radiography system, and a rotational gantry. Agreement between the isocenters of a room laser and a digital radiography system was examined visually. We used the star-shots method for detecting and verifying the rotational gantry isocenter. The gafchromic film could be irradiated with this method using a 2 mm slitted 200 MeV proton beam. The isocenters of a room laser and digital radiography system were in good agreement. The size distribution of the isocenter by the star-shots method was <2 mm, which is the value recommended by the American Association of Physicists in Medicine Task Group 142. This new device can be used to evaluate comprehensive isocenter detection and verification for related equipment. Subsequent checking using this new device will decrease the uncertainty in measuring an isocenter. When using this device, the working time was significantly reduced to about 30 min, including preparation. These measurements should be useful for high accuracy daily treatments.

Mesh:

Year:  2012        PMID: 23278028      PMCID: PMC3537708          DOI: 10.1063/1.4771576

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  10 in total

1.  The measurement of linear accelerator isocenter motion using a three-micrometer device and an adjustable pointer.

Authors:  J S Tsai; B H Curran; E S Sternick; M J Engler
Journal:  Int J Radiat Oncol Biol Phys       Date:  1996-01-01       Impact factor: 7.038

2.  A personal-computer-based method to obtain "star-shots" of mechanical and optical isocenters for gantry rotation of linear accelerators.

Authors:  M K Woo
Journal:  Med Phys       Date:  2002-12       Impact factor: 4.071

3.  A procedure to determine the radiation isocenter size in a linear accelerator.

Authors:  A González; I Castro; J A Martínez
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

4.  Mechanical and radiation isocenter coincidence: an experience in linear accelerator alignment.

Authors:  M K Woo; P O'Brien; B Gillies; R Etheridge
Journal:  Med Phys       Date:  1992 Mar-Apr       Impact factor: 4.071

5.  A system for stereotactic radiosurgery with a linear accelerator.

Authors:  W Lutz; K R Winston; N Maleki
Journal:  Int J Radiat Oncol Biol Phys       Date:  1988-02       Impact factor: 7.038

6.  A simple isocenter checking procedure for radiotherapy treatment machines using the optical pointer.

Authors:  F R Hudson
Journal:  Med Phys       Date:  1988 Jan-Feb       Impact factor: 4.071

7.  Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40.

Authors:  G J Kutcher; L Coia; M Gillin; W F Hanson; S Leibel; R J Morton; J R Palta; J A Purdy; L E Reinstein; G K Svensson
Journal:  Med Phys       Date:  1994-04       Impact factor: 4.071

Review 8.  AAPM code of practice for radiotherapy accelerators: report of AAPM Radiation Therapy Task Group No. 45.

Authors:  R Nath; P J Biggs; F J Bova; C C Ling; J A Purdy; J van de Geijn; M S Weinhous
Journal:  Med Phys       Date:  1994-07       Impact factor: 4.071

9.  Measurement of mechanical accuracy of isocenter in conventional linear-accelerator-based radiosurgery.

Authors:  F A Gibbs; D Buechler; D D Leavitt; J H Moeller
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-01       Impact factor: 7.038

10.  Verification procedure for isocentric alignment of proton beams.

Authors:  George Ciangaru; James N Yang; Patrick J Oliver; Martin Bues; Mengping Zhu; Fumio Nakagawa; Hitoshi Chiba; Shin Nakamura; Hirofumi Yoshino; Mosumi Umezawa; Alfred R Smith
Journal:  J Appl Clin Med Phys       Date:  2007-10-24       Impact factor: 2.102

  10 in total
  1 in total

1.  A new concept for verifying the isocentric alignment of the proton-rotational gantry for radiation control.

Authors:  Takahiro Kato; Yuhei Yamazaki; Tatsuhiko Sagara
Journal:  Radiol Phys Technol       Date:  2019-11-09
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.