Literature DB >> 23277807

Pulmonary aspiration associated with supraglottic airways: Proseal laryngeal mask airway and I-Gel™.

Yoon-Hee Kim1.   

Abstract

Entities:  

Year:  2012        PMID: 23277807      PMCID: PMC3531525          DOI: 10.4097/kjae.2012.63.6.489

Source DB:  PubMed          Journal:  Korean J Anesthesiol        ISSN: 2005-6419


× No keyword cloud information.
Supraglottic airways (SGAs) are increasingly used by SGA friendly users in patients who are traditionally assumed to be at an increased risk for aspiration. For instance, at first, its use was controversial, its airtight seal and the absence of gastric aspiration with the supraglottic airway during laparoscopic surgery was shown throughout "conventional" positive ventilation [1,2]. The evidence to date suggests that pulmonary aspiration associated with the supraglottic airway is rare and has an incidence comparable to that of outpatient anesthesia with the face mask and endotracheal tube [3]. However, in principal, supraglottic airways do not prevent gastric aspiration as reliably as tracheal intubaton does. The insertion of the SGA has been reported to increase the esophageal motility and to reduce the lower esophageal sphincter barrier pressure. A possible mechanism for this situation is that the distension of pharynx induced by large inflated cuff of the SGA trigger the pharyngo-esophago-gastric reflex [4]. When conscious, this reflex will facilitate swallowing. SGA with features, such as airtight sealing, separate access to the gastrointestinal and respiratory tracts and esophageal drainage tube improve the safety and efficacy of positive pressure ventilation, provide a means of gastric suctioning, reduce the gastric distension, and the risk of pulmonary aspiration. There are now several supraglottic airways marketed that are specifically designed to reduce the risk of aspiration. Five devices are designed to separate the respiratory and gastrointestinal tracts: the I-Gel™ (Intersurgical Ltd, Wokingham, Berkshire, UK), laryngeal tube suction mark II (LTS II) and its disposable version (LTS-D) (VBM GmbH, Sulz, Germany), the proseal laryngeal mask airway, the recently introduced laryngeal mask airway Supreme (Intavent Orthofix, Maidenhead, UK), and the streamlined liner of the pharyngeal airway (Teleflex Medical, High Wycombe, UK, SLIPA). The device SLIPA is designed to prevent aspiration through its large hollow chamber that can store up to 50 ml of regurgitant gastric fluid [5]. In this edition of Korean Journal of Anesthesiology, Jeon et al. [6] presented a clinical study on 30 patients undergoing laparoscopic gynecologic surgery with either a Proseal laryngeal mask airway or an I-Gel™ to secure the airway. The study showed that there was no significant difference in the leak fraction between the two airways. The authors concluded that I-Gel™ is a reasonable alternative to the Proseal laryngeal mask airway for controlled ventilation during laparoscopic gynecological surgery. Proseal laryngeal mask airway and I-Gel™ are second generation SGA that has high esophageal sealing pressure and esophageal drainage tube, effective in preventing gastric aspiration. The use of the Proseal laryngeal mask airway since been reported in a number of clinical situations, including elective laparoscopic surgery and even in patients ventilated in the prone position [7,8]. In addition to the use for planned anesthesia, current guidelines also recommend Proseal laryngeal mask airway as an alternative to tracheal intubation during cardiopulmonary resuscitation [9]. In a fresh cadaver model, where the esophagus was filled with fluid increase pressure, Proseal laryngeal mask airway showed complete protection during esophageal regurgitation when esophageal drainage tube was patent [10]. I-Gel™ is a noninflatable supraglottic airway made up of a thermoplastic elastomer (styrene ethylene butadiene styrene) with a soft durometer and gel-like feel. Supraglottic airways with inflatable cuff are effective sealing the airway, but inflation itself may cause the position of the device to change. On the other hand, a noninflatable I-Gel™ has potential advantages, including easier insertion, minimal tissue compression, and reduced risk of undesired changes of position after insertion [11]. A systematic investigation of the sealing efficacy with the I-Gel™ has not been reported yet. Gibbison et al. [5] reported a case series describing the cases of regurgitation with successful drainage through the gastric drainage tube and one aspiration with inadequate drainage out of 280 total patients. I-Gel™ provided leak pressures in the upper range of comparable supraglottic airway, but not as high as the Proseal Laryngeal Mask [12]. Schmidbauer et al. [10] suggest that at high esophageal pressures, the esophageal seal provided by the cuff of the laryngeal mask airway (Classic laryngeal mask airway or Proseal laryngeal mask airway) is superior to the esophageal seal created by the pre-shaped plastic mask body of I-Gel™. In addition, the esophageal drainage tube of the I-Gel™ (12 F for size 3 and 4 and 14 F for size 5) is smaller than for the Proseal laryngeal mask (16 F in a size 4 Proseal laryngeal mask). Also, the distal end of I-Gel™ is deformable, inefficiently draining regurgitant fluid from the smaller, deformable esophageal drainage tube [5]. In a magnetic resonance imaging study by Russo et al. [13], Supreme laryngeal mask airway, a disposable Proseal laryngeal mask airway, protruded the upper esophageal sphincter deeper than I-Gel™. The study suggesting that Proseal laryngeal mask airway is more effective than I-Gel™ in pulmonary aspiration. However, because correct positioning of SGA is important in protecting gastric aspiration, I-Gel™ with good position stability may have superiority over Proseal laryngeal mask, regarding this matter. A further comparison between the two is needed. Pulmonary aspiration during anesthesia was affected more often by inappropriate use rather than the inherent defect of the airway device itself. SGAs have attractive features, which include noninvasiveness, easiness and simplicity. With further revolution and advancements concern regarding risk of pulmonary aspiration is soon to take a turn for the better.
  13 in total

1.  A comparison of the laryngeal mask airway ProSeal and the laryngeal tube airway in paralyzed anesthetized adult patients undergoing pressure-controlled ventilation.

Authors:  Joseph Brimacombe; Christian Keller; Lawrence Brimacombe
Journal:  Anesth Analg       Date:  2002-09       Impact factor: 5.108

2.  Initial anatomic investigations of the I-gel airway: a novel supraglottic airway without inflatable cuff.

Authors:  R M Levitan; W C Kinkle
Journal:  Anaesthesia       Date:  2005-10       Impact factor: 6.955

3.  Advantages of ProSeal and SLIPA airways over tracheal tubes for gynecological laparoscopies.

Authors:  Donald M Miller; Luigi Camporota
Journal:  Can J Anaesth       Date:  2006-02       Impact factor: 5.063

4.  The LMA-ProSeal is an effective alternative to tracheal intubation for laparoscopic cholecystectomy.

Authors:  J Roger Maltby; Michael T Beriault; Neil C Watson; David Liepert; Gordon H Fick
Journal:  Can J Anaesth       Date:  2002-10       Impact factor: 5.063

5.  The incidence of aspiration associated with the laryngeal mask airway: a meta-analysis of published literature.

Authors:  J R Brimacombe; A Berry
Journal:  J Clin Anesth       Date:  1995-06       Impact factor: 9.452

6.  Regurgitation of gastric contents during general anaesthesia using the laryngeal mask airway.

Authors:  P Barker; J A Langton; P J Murphy; D J Rowbotham
Journal:  Br J Anaesth       Date:  1992-09       Impact factor: 9.166

7.  Case series: Protection from aspiration and failure of protection from aspiration with the i-gel airway.

Authors:  B Gibbison; T M Cook; C Seller
Journal:  Br J Anaesth       Date:  2008-01-29       Impact factor: 9.166

8.  LMA-Classic and LMA-ProSeal are effective alternatives to endotracheal intubation for gynecologic laparoscopy.

Authors:  J Roger Maltby; Michael T Beriault; Neil C Watson; David J Liepert; Gordon H Fick
Journal:  Can J Anaesth       Date:  2003-01       Impact factor: 5.063

9.  The proseal laryngeal mask airway in prone patients: a retrospective audit of 245 patients.

Authors:  J R Brimacombe; V Wenzel; C Keller
Journal:  Anaesth Intensive Care       Date:  2007-04       Impact factor: 1.669

10.  Comparison of the Proseal LMA and intersurgical I-gel during gynecological laparoscopy.

Authors:  Woo Jae Jeon; Sang Yun Cho; Seong Jin Baek; Kyoung Hun Kim
Journal:  Korean J Anesthesiol       Date:  2012-12-14
View more
  6 in total

Review 1.  Complications Associated with the Use of Supraglottic Airway Devices in Perioperative Medicine.

Authors:  Pavel Michalek; William Donaldson; Eliska Vobrubova; Marek Hakl
Journal:  Biomed Res Int       Date:  2015-12-13       Impact factor: 3.411

2.  I-gel™ May be the Device of Choice for Controlled Ventilation in Patients with Hemophilia Undergoing Abdominal Laparoscopic Surgery.

Authors:  Sreyashi Sen; Koel Mitra; Shanta Ganguli; Sudakshina Mukherji
Journal:  Anesth Essays Res       Date:  2018 Jan-Mar

Review 3.  Endotracheal Intubation in the Pharmaceutical-Poisoned Patient: a Narrative Review of the Literature.

Authors:  Glenn A Burket; B Zane Horowitz; Robert G Hendrickson; Gillian A Beauchamp
Journal:  J Med Toxicol       Date:  2020-05-11

4.  Comparison of intragastric pressure between endotracheal tube and supraglottic airway devices in laparoscopic hepatectomy: A randomized, controlled, non-inferiority study.

Authors:  Jin Hee Ahn; Ji Seon Jeong; Se Hee Kang; Ji Eun Yeon; Eun A Cho; Gyu Sung Choi; Jong Man Kim; Gaab Soo Kim
Journal:  Medicine (Baltimore)       Date:  2021-06-18       Impact factor: 1.817

5.  Successful use of i-gel™ in a patient with tracheal stenosis undergoing Montgomery t-tube insertion.

Authors:  Hyun Sik Chung; Ji Yong Kim; Jung Ah Kwak; Chul Soo Park
Journal:  Korean J Anesthesiol       Date:  2013-12

Review 6.  Comparison of oropharyngeal leak pressure and clinical performance of LMA ProSeal™ and i-gel® in adults: Meta-analysis and systematic review.

Authors:  Hye Won Shin; Hae Na Yoo; Go Eun Bae; Jun Chul Chang; Min Kyung Park; Hae Seun You; Hyun Jung Kim; Hyung Sik Ahn
Journal:  J Int Med Res       Date:  2016-03-23       Impact factor: 1.671

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.