Literature DB >> 16434761

Advantages of ProSeal and SLIPA airways over tracheal tubes for gynecological laparoscopies.

Donald M Miller1, Luigi Camporota.   

Abstract

PURPOSE: To compare the efficacy of the ProSeal LMA and SLIPA supralaryngeal airways (SLA) with the standard tracheal tube (TT) in 150 consecutive day-case laparoscopic gynecological surgery procedures requiring general anesthesia.
METHODS: One hundred and fifty patients were randomized into three groups. An identical general anesthesia technique was used in all patients apart from the addition of muscle relaxants and reversal drugs in the TT group. Patients were excluded if there were risk factors for gastroesophageal reflux. Ease of use, quality of seal, ventilation, systolic pressure, response to intubation, side effects and operating room time were assessed.
RESULTS: Both ProSeal LMA and SLIPA were easy to insert (100% success) and ventilate with respective mean (standard deviation) maximum sealing pressures of 31 (4.6) and 30 (5.2) cmH2O (P = 0.4) with no muscle relaxants. The seal quality in both ProSeal LMA and SLIPA permitted the use of low flows, 485 (291) and 539 (344) mL x min(-1) (P = 0.2) respectively, although in the TT group significantly lower flows [377 (124) mL x min(-1)], (P < 0.01) were achieved. Systolic pressure in the SLA groups was more stable in response to insertion than in the TT. With ProSeal there was a lower incidence of sore throats than with TT (30% vs 57%), (P < 0.05), but there was a lesser difference as compared with SLIPA (30% vs 49%), (P > 0.05). With both SLAs, there was a significant reduction in operating room time (> three minutes), (P < 0.001).
CONCLUSIONS: These results suggest that the ProSeal LMA (reusable) and SLIPA (single-use) SLAs were easy to use without requiring muscle relaxants, and reduce operating room time compared to the TT technique in day case laparoscopies.

Entities:  

Mesh:

Year:  2006        PMID: 16434761     DOI: 10.1007/BF03021826

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  16 in total

1.  Comparison of LM-Supreme™ and endotracheal tube in patients undergoing gynecological laparoscopic surgery.

Authors:  Bahar Kuvaki; Şule Özbilgin; Sakize Ferim Günenç; Burcu Ataseven Küçük
Journal:  J Clin Monit Comput       Date:  2019-04-09       Impact factor: 2.502

2.  Preheating of streamlined liner of pharyngeal airway (SLIPA) reduced the related complications: a randomized control study.

Authors:  Guiqi Geng; Yingjie Chen; Hailian Liu
Journal:  J Clin Monit Comput       Date:  2016-04-08       Impact factor: 2.502

3.  The clinical effectiveness of the streamlined liner of pharyngeal airway (SLIPA) compared with the laryngeal mask airway ProSeal during general anesthesia.

Authors:  Yun Mi Choi; Su Man Cha; Hyun Kang; Chong Wha Baek; Yong Hun Jung; Young Cheol Woo; Jin Yun Kim; Gill Hoi Koo; Sun Gyoo Park
Journal:  Korean J Anesthesiol       Date:  2010-05-29

4.  A novel method for SLIPA™ size selection, for adult patients, on the basis of chamber length.

Authors:  Yansong Li; Ying Xie; Xinchuan Wei
Journal:  J Anesth       Date:  2013-02-27       Impact factor: 2.078

Review 5.  Role of laryngeal mask airway in laparoscopic cholecystectomy.

Authors:  José M Beleña; Ernesto Josué Ochoa; Mónica Núñez; Carlos Gilsanz; Alfonso Vidal
Journal:  World J Gastrointest Surg       Date:  2015-11-27

6.  Pulmonary aspiration associated with supraglottic airways: Proseal laryngeal mask airway and I-Gel™.

Authors:  Yoon-Hee Kim
Journal:  Korean J Anesthesiol       Date:  2012-12-14

7.  Comparison of streamlined liner of the pharynx airway (SLIPA™) with the laryngeal mask airway Proseal™ for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients.

Authors:  Ashraf Abualhassan Abdellatif; Monaz Abdulrahman Ali
Journal:  Saudi J Anaesth       Date:  2011-07

8.  Comparison of the proseal, supreme, and i-gel SAD in gynecological laparoscopic surgeries.

Authors:  Sanli Mukadder; Begec Zekine; Kayhan Gulay Erdogan; Ozgul Ulku; Ucar Muharrem; Yologlu Saim; Durmus Mahmut
Journal:  ScientificWorldJournal       Date:  2015-02-23

9.  Comparison of the clinical effectiveness between the streamlined liner of pharyngeal airway (SLIPA) and the laryngeal mask airway by novice personnel.

Authors:  Seok-Kyeong Oh; Byung Gun Lim; Heezoo Kim; Sang Ho Lim
Journal:  Korean J Anesthesiol       Date:  2012-08-14

10.  AutoFlow® versus volume-controlled ventilation for laparoscopic gynecological surgery using LMA® ProSeal™: a randomized controlled trial.

Authors:  Toshiyuki Nakanishi; Seishi Sakamoto; Manabu Yoshimura; Takashi Toriumi
Journal:  BMC Anesthesiol       Date:  2021-06-28       Impact factor: 2.217

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.