Literature DB >> 23276731

The effect of static force on round window stimulation with the direct acoustic cochlea stimulator.

Hannes Maier1, Rolf Salcher, Burkard Schwab, Thomas Lenarz.   

Abstract

The Direct Acoustic Cochlea Stimulator Partial Implant (DACS PI, Phonak Acoustic Implants SA, Switzerland) is intended to stimulate the cochlea by a conventional stapedotomy piston that is crimped onto the DACS PI artificial incus. An alternative approach to the round window (RW) is successfully done with other devices, having the advantage of being also independent of the existence of middle ear structure (e.g. ossicles). Here the possibility of stimulating the RW with the DACS actuator is investigated including the impact of static force on sound transmission to the cochlea. The maximum equivalent sound pressure output with RW stimulation was determined experimentally in fresh human temporal bones. Experiments were performed in analogy to the ASTM standard (F2504.24930-1) method for the output determination of implantable middle ear hearing devices (IMEHDs) in human cadaveric temporal bones (TBs). ASTM compliant temporal bones were stimulated with a prosthesis having a spherical tip (∅0.5 mm) attached to the actuator. The stimulation was performed perpendicular to the round window membrane (RWM) at varying position relative to the RW and the resulting static force on the RW membrane was determined. At each position the displacement output of the DACS PI actuator and the stapes footplate (SFP) vibration in response to actuator stimulation was measured with a Laser Doppler Velocimeter (LDV). By comparison of the achieved output at the stapes footplate in response to sound and transducer stimulation the equivalent sound pressure level at the tympanic membrane at 1Vrms input voltage was calculated assuming that the SFP displacement in both conditions is a measure of perceived loudness, as it is done in the ASTM standard. Ten TB preparations within the acceptance range of the ASTM standard were used for analysis. The actuator driven stapes footplate displacement amplitude as well as the resulting equivalent sound pressure level was highly dependent on the static force applied to the RW. The sound transfer efficiency from the RW to the stapes footplate increased monotonically with increasing static load. At a moderate static force load (approx. 3.9 mN) the obtained average sound equivalent sound pressure level was 102-120 eq. dB SPL @ nominally 1Vrms input for frequencies ≤4 kHz. At higher frequencies (6-10 kHz) the achieved output dropped to ∼90 dB SPL. This output was obtained at loading conditions compatible with the actuator safe operating range, although it was possible to increase the output further by increasing the static force load. Our results demonstrate for a first time that static force applied to the RW is crucial for sound transmission efficiency. Further we could show that RW stimulation with the DACS PI actuator is possible having a maximum output that is sufficient to treat moderate and pronounced sensorineural hearing losses (SNHL). This article is part of a Special Issue entitled "MEMRO 2012".
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23276731     DOI: 10.1016/j.heares.2012.12.010

Source DB:  PubMed          Journal:  Hear Res        ISSN: 0378-5955            Impact factor:   3.208


  14 in total

Review 1.  [The Vibrant Soundbridge as an active implant in middle ear surgery].

Authors:  T Beleites; M Bornitz; M Neudert; T Zahnert
Journal:  HNO       Date:  2014-07       Impact factor: 1.284

2.  Performance of the round window soft coupler for the backward stimulation of the cochlea in a temporal bone model.

Authors:  Antoniu-Oreste Gostian; David Schwarz; Philipp Mandt; Andreas Anagiotos; Magdalene Ortmann; David Pazen; Dirk Beutner; Karl-Bernd Hüttenbrink
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-03-28       Impact factor: 2.503

Review 3.  [Active hearing implants in chronic otitis media].

Authors:  S Lailach; C Müller; N Lasurashvili; H Seidler; T Zahnert
Journal:  HNO       Date:  2021-06       Impact factor: 1.284

Review 4.  Design and optimization of auditory prostheses using the finite element method: a narrative review.

Authors:  Qianli Cheng; Han Yu; Junpei Liu; Qi Zheng; Yanru Bai; Guangjian Ni
Journal:  Ann Transl Med       Date:  2022-06

5.  [Direct acoustic cochlear stimulation for therapy of severe to profound mixed hearing loss: Codacs™ Direct Acoustic Cochlear Implant System].

Authors:  T Lenarz; B Schwab; H Maier; E Kludt
Journal:  HNO       Date:  2014-07       Impact factor: 1.284

6.  Impedances of the inner and middle ear estimated from intracochlear sound pressures in normal human temporal bones.

Authors:  Darcy L Frear; Xiying Guan; Christof Stieger; John J Rosowski; Hideko Heidi Nakajima
Journal:  Hear Res       Date:  2018-06-30       Impact factor: 3.208

7.  A novel mechanism of cochlear excitation during simultaneous stimulation and pressure relief through the round window.

Authors:  Thomas D Weddell; Yury M Yarin; Markus Drexl; Ian J Russell; Stephen J Elliott; Andrei N Lukashkin
Journal:  J R Soc Interface       Date:  2014-02-05       Impact factor: 4.118

8.  The Codacs™ direct acoustic cochlear implant actuator: exploring alternative stimulation sites and their stimulation efficiency.

Authors:  Martin Grossöhmichen; Rolf Salcher; Hans-Heinrich Kreipe; Thomas Lenarz; Hannes Maier
Journal:  PLoS One       Date:  2015-03-18       Impact factor: 3.240

9.  Direct Acoustic Stimulation at the Lateral Canal: An Alternative Route to the Inner Ear?

Authors:  Nicolas Verhaert; Joris Walraevens; Christian Desloovere; Jan Wouters; Jean-Marc Gérard
Journal:  PLoS One       Date:  2016-08-08       Impact factor: 3.240

10.  Differential Intracochlear Sound Pressure Measurements in Human Temporal Bones with an Off-the-Shelf Sensor.

Authors:  Martin Grossöhmichen; Rolf Salcher; Klaus Püschel; Thomas Lenarz; Hannes Maier
Journal:  Biomed Res Int       Date:  2016-08-16       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.