Literature DB >> 23276713

RGP contact lens fitting in keratoconus using FITSCAN technology.

Preeji S Mandathara1, Mariya Fatima, Sobia Taureen, Srikanth Dumpati, Mohd Hasnat Ali, Varsha Rathi.   

Abstract

PURPOSE: To assess and compare the base curve (BC) of rigid gas permeable contact lens (RGP) that were calculated by FITSCAN using corneal topography (Orbscan IIz) and the diagnostic contact lens fitting method in keratoconus eyes.
MATERIALS AND METHODS: A prospective comparative study of 85 keratoconus eyes was conducted. Two masked observers calculated the contact lens parameters of RGP lens by diagnostic fitting method and using FITSCAN technology. The base curves calculated by two methods were compared using Wilcoxon signed rank test and agreement between two methods were analysed using Bland-Altman plot.
RESULTS: Eighty-five eyes from 55 keratoconus patients were included in the study. The mean age was 17.63±2.78 (range: 12-23) years and among them 46 were males. The keratoconus was graded into mild, moderate and severe based on average keratometry values. The base curve calculated by the FITSCAN is on average 0.22mm higher than that calculated by diagnostic method (P value <0.0001, 95% CI=0.155, 0.245, Wilcoxon signed rank test) and the bias between the two methods was found to be 2.7% (Bland-Altman plot), indicating systematic bias between the two modalities. By single linear regression analysis, the base curve of RGP contact lens could calculated by using the formula, base curve (BC)=(FITSCAN calculated BC×0.86563)+0.78738.
CONCLUSION: Our study showed that selecting the BC of the initial trial lens 0.22mm steeper than the FITSCAN calculated base curve, may help to reduce the complexity of RGP contact lens fitting in keratoconus.
Copyright © 2012 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23276713     DOI: 10.1016/j.clae.2012.12.002

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  4 in total

Review 1.  Current perspectives in the management of keratoconus with contact lenses.

Authors:  Li Lim; Elizabeth Wen Ling Lim
Journal:  Eye (Lond)       Date:  2020-07-08       Impact factor: 3.775

Review 2.  Nonsurgical Procedures for Keratoconus Management.

Authors:  L Rico-Del-Viejo; M Garcia-Montero; J L Hernández-Verdejo; S García-Lázaro; F J Gómez-Sanz; A Lorente-Velázquez
Journal:  J Ophthalmol       Date:  2017-12-21       Impact factor: 1.909

3.  Gas permeable contact lens fitting in keratoconus: Comparison of different guidelines to back optic zone radius calculations.

Authors:  Sara Ortiz-Toquero; Guadalupe Rodriguez; Victoria de Juan; Raul Martin
Journal:  Indian J Ophthalmol       Date:  2019-09       Impact factor: 1.848

4.  Contact lens fitting after corneal collagen cross-linking.

Authors:  Preeji Suderman Mandathara; Parthasarathi Kalaiselvan; Varsha M Rathi; Somasheila I Murthy; Mukesh Taneja; Virender S Sangwan
Journal:  Oman J Ophthalmol       Date:  2019-10-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.