Literature DB >> 23273529

Differential prognostic effect of intravascular ultrasound use according to implanted stent length.

Jung-Min Ahn1, Seungbong Han, Yong Kyu Park, Woo Seok Lee, Jeong Yoon Jang, Chang Hee Kwon, Gyung-Min Park, Young-Rak Cho, Jong-Young Lee, Won-Jang Kim, Duk-Woo Park, Soo-Jin Kang, Seung-Whan Lee, Young-Hak Kim, Cheol Whan Lee, Jae-Joong Kim, Seong-Wook Park, Seung-Jung Park.   

Abstract

It is unknown whether the use of intravascular ultrasound (IVUS) guidance during percutaneous coronary intervention can attenuate the stent length effect on clinical outcomes. The aim of the present study was to determine the differential prognostic effect of IVUS according to the implanted stent length. We enrolled 3,244 consecutive patients from the Interventional Cardiology Research In-cooperation Society-Drug-Eluting Stents (IRIS-DES) registry who had undergone single or overlapping stent implantation. The primary end point was major adverse cardiac events (MACE; a composite of death, myocardial infarction, and target vessel revascularization). The study population was divided by the tertiles of implanted stent length and IVUS usage. IVUS use was at the discretion of the operator. After adjusting for significant covariates, the stent length was significantly associated with the risk of MACE in the no-IVUS group (hazard ratio 1.13, 95% confidence interval 1.01 to 1.28, p = 0.042) but not in the IVUS group (hazard ratio 1.08, 95% confidence interval 0.97 to 1.20, p = 0.16). In addition, in patients with an implanted stent length of ≤22 mm (n = 998), the risk of MACE was not significantly different between the IVUS group and the no-IVUS group (hazard ratio 1.06, 95% confidence interval 0.50 to 2.28, p = 0.88). In contrast, in patients with a longer implanted stent length, the risk of MACE was significantly lower in the IVUS group than in the no-IVUS group (hazard ratio 0.47, 95% confidence interval 0.24 to 0.92, p = 0.027 for 23 to 32 mm, n = 1,109; hazard ratio 0.57, 95% confidence interval 0.33 to 0.98, p = 0.042 for ≥33 mm, n = 1,137). In conclusion, IVUS usage can attenuate the detrimental effect of the increase in the implanted stent length, supporting IVUS usage, particularly during percutaneous coronary intervention with long stent implantation.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23273529     DOI: 10.1016/j.amjcard.2012.11.054

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  6 in total

1.  Frequency and prognostic impact of intravascular imaging-guided urgent percutaneous coronary intervention in patients with acute myocardial infarction: results from J-MINUET.

Authors:  Hiroyuki Okura; Yoshihiko Saito; Tsunenari Soeda; Koichi Nakao; Yukio Ozaki; Kazuo Kimura; Junya Ako; Teruo Noguchi; Satoshi Yasuda; Satoru Suwa; Kazuteru Fujimoto; Yasuharu Nakama; Takashi Morita; Wataru Shimizu; Atsushi Hirohata; Yasuhiro Morita; Teruo Inoue; Atsunori Okamura; Masaaki Uematsu; Kazuhito Hirata; Kengo Tanabe; Yoshisato Shibata; Mafumi Owa; Kenichi Tsujita; Kunihiro Nishimura; Yoshihiro Miyamoto; Masaharu Ishihara
Journal:  Heart Vessels       Date:  2018-11-02       Impact factor: 2.037

2.  Real-world use of intravascular ultrasound in Japan: a report from contemporary multicenter PCI registry.

Authors:  Toshiki Kuno; Yohei Numasawa; Mitsuaki Sawano; Takayuki Abe; Ikuko Ueda; Masaki Kodaira; Masahiro Suzuki; Shigetaka Noma; Iwao Nakamura; Koji Negishi; Shiro Ishikawa; Keiichi Fukuda; Shun Kohsaka
Journal:  Heart Vessels       Date:  2019-05-25       Impact factor: 2.037

Review 3.  Practical application of coronary imaging devices in cardiovascular intervention.

Authors:  Yun-Kyeong Cho; Seung-Ho Hur
Journal:  Korean Circ J       Date:  2015-03-24       Impact factor: 3.243

4.  Intravascular Ultrasound Guidance Improves the Long-term Prognosis in Patients with Unprotected Left Main Coronary Artery Disease Undergoing Percutaneous Coronary Intervention.

Authors:  Jian Tian; Changdong Guan; Wenyao Wang; Kuo Zhang; Jue Chen; Yongjian Wu; Hongbing Yan; Yanyan Zhao; Shubin Qiao; Yuejin Yang; Gary S Mintz; Bo Xu; Yida Tang
Journal:  Sci Rep       Date:  2017-05-24       Impact factor: 4.379

5.  In vivo measurement of stent length by using intravascular ultrasound.

Authors:  Magdy Algowhary; Salma Taha; Hosam Hasan-Ali; Akihiko Matsumura
Journal:  Egypt Heart J       Date:  2019-12-19

Review 6.  Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis.

Authors:  Yao-Jun Zhang; Si Pang; Xiao-Yun Chen; Christos V Bourantas; Dao-Rong Pan; Sheng-Jie Dong; Wen Wu; Xiao-Min Ren; Hao Zhu; Shun-Yi Shi; Javaid Iqbal; Bill D Gogas; Bo Xu; Shao-Liang Chen
Journal:  BMC Cardiovasc Disord       Date:  2015-11-17       Impact factor: 2.298

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.