Use of ITAP implants for prosthetic reconstruction of extra-oral craniofacial defects.

Norbert V Kang1, Daniel Morritt, Catherine Pendegrass, Gordon Blunn.   

Abstract

We report the outcomes of a single-stage, surface-mounted implant used as a bone-anchor for prosthetic reconstruction of complex facial defects. The implant used differs from other designs of osseointegrated bone-anchor because it was designed to be implanted in one-stage with the added intention of integrating with the adjacent soft-tissue. Our aim was to extend the principles underlying the intraosseous transcutaneous amputation prosthesis (ITAP) into the design of infection-free implants suitable for direct skeletal attachment of a prosthesis to the craniofacial skeleton. The implants were manufactured incorporating a porous flange structure coated with hydroxyapatite to encourage soft-tissue integration. These were inserted into the cranial facial skeleton at a number of different sites in 6 adult patients. A total of 16 implants were inserted using a one-stage procedure and implants were followed up for periods of 18 months - 7 years. One implant loosened at 3 months. This implant experienced multiple episodes of infection and was replaced with another ITAP implant 4 years later. The replacement is now stable and has never been infected at 18 months after insertion. One other patient experienced a few minor episodes of superficial infection (not requiring antibiotics) in the first year but no episodes thereafter. One patient died during follow-up (death unrelated to implant surgery). Patients were asked for their personal opinions using a structured questionnaire. All the patients were either very satisfied, or satisfied with their ITAP implants. Two patients reported problems with skin irritation under their prosthesis. All would be happy to undergo this type of surgery again. We conclude that a single-stage, surface-mounted implant designed to incorporate the principles of ITAP can be used to produce an effective bone-anchor for an external prosthesis in the reconstruction of complex craniofacial defects.
Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23270664     DOI: 10.1016/j.bjps.2012.11.036

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  7 in total

1.  Biomimetic coatings and negative pressure wound therapy independently limit epithelial downgrowth around percutaneous devices.

Authors:  Sujee Jeyapalina; Saranne J Mitchell; Jayant Agarwal; Kent N Bachus
Journal:  J Mater Sci Mater Med       Date:  2019-06-10       Impact factor: 3.896

2.  A 24-month evaluation of a percutaneous osseointegrated limb-skin interface in an ovine amputation model.

Authors:  Sujee Jeyapalina; James Peter Beck; Jayant Agarwal; Kent N Bachus
Journal:  J Mater Sci Mater Med       Date:  2017-10-04       Impact factor: 3.896

3.  Prosthetic supply of facial defects: long-term experience and retrospective analysis on 99 patients.

Authors:  Giorgos Papaspyrou; Cansel Yildiz; Victoria Bozzato; Christopher Bohr; Mathias Schneider; Dietmar Hecker; Bernhard Schick; Basel Al Kadah
Journal:  Eur Arch Otorhinolaryngol       Date:  2017-12-14       Impact factor: 2.503

Review 4.  Large Animal Models in Regenerative Medicine and Tissue Engineering: To Do or Not to Do.

Authors:  Iris Ribitsch; Pedro M Baptista; Anna Lange-Consiglio; Luca Melotti; Marco Patruno; Florien Jenner; Eva Schnabl-Feichter; Luke C Dutton; David J Connolly; Frank G van Steenbeek; Jayesh Dudhia; Louis C Penning
Journal:  Front Bioeng Biotechnol       Date:  2020-08-13

5.  Can the Hydroxyapatite-Coated Skin-Penetrating Abutment for Bone Conduction Hearing Implants Integrate with the Surrounding Skin?

Authors:  Marc van Hoof; Stina Wigren; Hans Duimel; Paul H M Savelkoul; Mark Flynn; Robert Jan Stokroos
Journal:  Front Surg       Date:  2015-09-14

6.  The Micro Topology and Statistical Analysis of the Forces of Walking and Failure of an ITAP in a Femur.

Authors:  Euan Langford; Christian Andrew Griffiths; Andrew Rees; Josh Bird
Journal:  Micromachines (Basel)       Date:  2021-03-12       Impact factor: 2.891

Review 7.  Outcome measures in facial prosthesis research: A systematic review.

Authors:  Rachael Y Jablonski; Benjamin J Veale; Trevor J Coward; Andrew J Keeling; Chris Bojke; Sue H Pavitt; Brian R Nattress
Journal:  J Prosthet Dent       Date:  2021-02-10       Impact factor: 3.426