Literature DB >> 23262690

Liquid crystal polymer full-stokes division of focal plane polarimeter.

Graham Myhre1, Wei-Liang Hsu, Alba Peinado, Charles LaCasse, Neal Brock, Russell A Chipman, Stanley Pau.   

Abstract

A division-of-focal-plane polarimeter based on a dichroic dye and liquid crystal polymer guest-host system is presented. Two Stokes polarimeters are demonstrated: a linear Stokes and the first ever Full-Stokes division-of-focal-plane polarimeter. The fabrication, packaging, and characterization of the systems are presented. Finally, optimized polarimeter designs are discussed for future works.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23262690     DOI: 10.1364/OE.20.027393

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  8 in total

1.  Interferometric Sensor of Wavelength Detuning Using a Liquid Crystalline Polymer Waveplate.

Authors:  Paweł Wierzba
Journal:  Sensors (Basel)       Date:  2016-05-09       Impact factor: 3.576

2.  Design and Calibration of a Novel Bio-Inspired Pixelated Polarized Light Compass.

Authors:  Guoliang Han; Xiaoping Hu; Junxiang Lian; Xiaofeng He; Lilian Zhang; Yujie Wang; Fengliang Dong
Journal:  Sensors (Basel)       Date:  2017-11-14       Impact factor: 3.576

3.  Full-Stokes polarization imaging method based on the self-organized grating array in fused silica.

Authors:  Canhua Xu; Chaozhen Ke; Jing Ma; Yantang Huang; Zhiping Zeng
Journal:  Sci Rep       Date:  2018-02-05       Impact factor: 4.379

4.  Stable mid-infrared polarization imaging based on quasi-2D tellurium at room temperature.

Authors:  Lei Tong; Xinyu Huang; Peng Wang; Lei Ye; Meng Peng; Licong An; Qiaodong Sun; Yong Zhang; Guoming Yang; Zheng Li; Fang Zhong; Fang Wang; Yixiu Wang; Maithilee Motlag; Wenzhuo Wu; Gary J Cheng; Weida Hu
Journal:  Nat Commun       Date:  2020-05-08       Impact factor: 14.919

5.  Passive broadband full Stokes polarimeter using a Fresnel cone.

Authors:  R D Hawley; J Cork; N Radwell; S Franke-Arnold
Journal:  Sci Rep       Date:  2019-02-25       Impact factor: 4.379

6.  Polarization-probe polarization-imaging system in near-infrared regime using a polarization grating.

Authors:  Moritsugu Sakamoto; Huynh Thanh Nhan; Kohei Noda; Tomoyuki Sasaki; Masayuki Tanaka; Nobuhiro Kawatsuki; Hiroshi Ono
Journal:  Sci Rep       Date:  2022-09-10       Impact factor: 4.996

7.  Survey of Demosaicking Methods for Polarization Filter Array Images.

Authors:  Sofiane Mihoubi; Pierre-Jean Lapray; Laurent Bigué
Journal:  Sensors (Basel)       Date:  2018-10-30       Impact factor: 3.576

8.  Bioinspired Polarization Imaging Sensors: From Circuits and Optics to Signal Processing Algorithms and Biomedical Applications: Analysis at the focal plane emulates nature's method in sensors to image and diagnose with polarized light.

Authors:  Timothy York; Samuel B Powell; Shengkui Gao; Lindsey Kahan; Tauseef Charanya; Debajit Saha; Nicholas W Roberts; Thomas W Cronin; Justin Marshall; Samuel Achilefu; Spencer P Lake; Baranidharan Raman; Viktor Gruev
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2014-08-20       Impact factor: 10.961

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.