Literature DB >> 23249878

Does peritoneal dialysate affect body composition assessments using multi-frequency bioimpedance in peritoneal dialysis patients?

A Davenport1.   

Abstract

BACKGROUND/
OBJECTIVES: Multi-frequency bioelectrical impedance analysis (MFBIA) is increasingly being used to assess peritoneal dialysis patients. Protein energy wasting (PEW) is a recognised complication of peritoneal dialysis. Although MFBIA can be used to assess body composition, measurements can be affected by fluid overload, and we wished to determine whether the presence of peritoneal dialysate in the peritoneal cavity equally could affect MFBIA-derived body composition assessments. SUBJECTS/
METHODS: Fifty consecutive adult patients had MFBIA made with 2l 22.7 g/l dextrose dialysate instilled into the peritoneal cavity and then after draining out.
RESULTS: When full, extracellular water (ECW) and the ratio of ECW to total body water (TBW) were greater compared with when empty: 13.9 ± 3.0l versus 13.4 ± 3.0, and 0.393 ± 0.01 versus 0.391 ± 0.01, P<0.001, respectively. Segmental ECW/TBW was only different for the trunk, 0.395 ± 0.01 full versus 0.392 ± 0.01 empty, P<0.0001. Body composition changed with a fall in skeletal muscle mass from 26.1 ± 6.3 to 25.2 ± 6.1 kg, P<0.001, and a smaller reduction in body fat from 19.3 ± 8.4 to 19.1 ± 8.0 kg, P=0.0104.
CONCLUSION: MFBIA measurements made in peritoneal dialysis patients with peritoneal dialysate instilled can overestimate body composition, including muscle mass, and as such potentially delay the recognition of PEW. Thus, for more accurate MFBIA in peritoneal dialysis patients, the dialysate should be drained out.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23249878     DOI: 10.1038/ejcn.2012.205

Source DB:  PubMed          Journal:  Eur J Clin Nutr        ISSN: 0954-3007            Impact factor:   4.016


  12 in total

1.  Can non-invasive measurements aid clinical assessment of volume in patients with cirrhosis?

Authors:  Andrew Davenport; Banwari Argawal; Gavin Wright; Konstantinos Mantzoukis; Rumyana Dimitrova; Joseph Davar; Panayota Vasianopoulou; Andrew K Burroughs
Journal:  World J Hepatol       Date:  2013-08-27

2.  The Effect of Fluid Overload on Clinical Outcome in Southern Chinese Patients Undergoing Continuous Ambulatory Peritoneal Dialysis.

Authors:  Qunying Guo; Jianxiong Lin; Jianying Li; Chunyan Yi; Haiping Mao; Xiao Yang; Xueqing Yu
Journal:  Perit Dial Int       Date:  2015-07-07       Impact factor: 1.756

3.  Changes in muscle and fat mass with haemodialysis detected by multi-frequency bioelectrical impedance analysis.

Authors:  K Panorchan; A Nongnuch; S El-Kateb; C Goodlad; A Davenport
Journal:  Eur J Clin Nutr       Date:  2015-06-03       Impact factor: 4.016

4.  Screening for muscle loss in patients established on peritoneal dialysis using bioimpedance.

Authors:  G H B Greenhall; A Davenport
Journal:  Eur J Clin Nutr       Date:  2016-10-26       Impact factor: 4.016

5.  Evaluation of body composition and fluid volume using a body composition monitor: does intraperitoneal fluid matter?

Authors:  Rafaela Siviero Caron-Lienert; Ana E Figueiredo; Bartira Pinheiro da Costa; Cristina F Bombardelli; Alessandra C Pizzato; Alessandra Conti; Carlos E Poli-de-Figueiredo
Journal:  Perit Dial Int       Date:  2014-06       Impact factor: 1.756

6.  Bioimpedance Guided Fluid Management in Peritoneal Dialysis: A Randomized Controlled Trial.

Authors:  Na Tian; Xiao Yang; Qunying Guo; Qian Zhou; Chunyan Yi; Jianxiong Lin; Peiyi Cao; Hongjian Ye; Menghua Chen; Xueqing Yu
Journal:  Clin J Am Soc Nephrol       Date:  2020-05-07       Impact factor: 8.237

7.  Is overhydration in peritoneal dialysis patients associated with cardiac mortality that might be reversible?

Authors:  Elizabeth Oei; Klara Paudel; Annemarie Visser; Hazel Finney; Stanley L Fan
Journal:  World J Nephrol       Date:  2016-09-06

8.  Non-invasive assessment of muscle injury in healthy and dystrophic animals with electrical impedance myography.

Authors:  Benjamin Sanchez; Shama R Iyer; Jia Li; Kush Kapur; Su Xu; Seward B Rutkove; Richard M Lovering
Journal:  Muscle Nerve       Date:  2017-03-24       Impact factor: 3.217

9.  Intraperitoneal fluid overestimates hydration status assessment by bioimpedance spectroscopy.

Authors:  David Arroyo; Nayara Panizo; Soraya Abad; Almudena Vega; Abraham Rincón; Ana Pérez de José; Juan M López-Gómez
Journal:  Perit Dial Int       Date:  2014-03-01       Impact factor: 1.756

10.  Changes in body composition following haemodialysis as assessed by bioimpedance spectroscopy.

Authors:  K Tangvoraphonkchai; A Davenport
Journal:  Eur J Clin Nutr       Date:  2016-09-28       Impact factor: 4.016

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.