Literature DB >> 23247401

The use of mass depletion-mass flux reduction relationships during pumping to determine source zone mass of a reactive brominated-solvent DNAPL.

C D Johnston1, G B Davis, T P Bastow, M D Annable, M G Trefry, A Furness, Y Geste, R J Woodbury, P S C Rao, S Rhodes.   

Abstract

Mass depletion-mass flux relationships usually applied to a groundwater plume were established at field scale for groundwater pumped from within the source zone of a dense non-aqueous phase liquid (DNAPL). These were used as part of multiple lines of evidence in establishing the DNAPL source mass and architecture. Simplified source mass-dissolved concentration models including those described by exponential, power, and error functions as well as a rational mass equation based on the equilibrium stream tube approach were fitted to data from 285 days of source zone pumping (SZP) from a single well which removed 152 kg of dissolved organics from a multi-component, reactive brominated solvent DNAPL. The total molar concentration of the source compound, tetrabromoethane and its daughter products was used as a single measure of contaminant concentration to relate to source mass. A partitioning inter-well tracer test (PITT) conducted prior to the SZP provided estimates of groundwater travel times, enabling parameterisation of the models. After accounting for capture of the down-gradient dissolved plume, all models provided a good fit to the observed data. It was shown that differentiation between models would only emerge after appreciably more pumping from the source zone. The model fits were not particularly sensitive to the exponent parameters and variance of groundwater travel time. In addition, the multi-component nature of the DNAPL did not seem to affect the utility of the models for the period examined. Estimates of the DNAPL mass prior to the start of SZP from the models were greatest where the log of the variance of travel time was used explicitly in the source depletion models (mean 295kg) compared to where the associated power exponent and variance was fitted freely (mean 258 kg). The estimates of source mass were close to that of 220kg determined from the PITT. In addition to the PITT, multi-level groundwater sampling from within the source zone provided important supporting information for developing the conceptual model of the source zone. It is concluded that SZP may be an effective and relatively simple means for characterising DNAPL source zones. Crown
Copyright © 2012. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23247401     DOI: 10.1016/j.jconhyd.2012.11.005

Source DB:  PubMed          Journal:  J Contam Hydrol        ISSN: 0169-7722            Impact factor:   3.188


  3 in total

1.  Source strength functions from long-term monitoring data and spatially distributed mass discharge measurements.

Authors:  Michael C Brooks; A Lynn Wood; Jaehyun Cho; Christine A P Williams; William Brandon; Michael D Annable
Journal:  J Contam Hydrol       Date:  2018-09-21       Impact factor: 3.188

2.  An empirical model for the evaluation of the dissolution rate from a DNAPL-contaminated area.

Authors:  Antonella Luciano; Giuseppe Mancini; Vincenzo Torretta; Paolo Viotti
Journal:  Environ Sci Pollut Res Int       Date:  2018-10-02       Impact factor: 4.223

3.  Modified Well-Field Configurations for Improved Performance of Contaminant Elution and Tracer Tests.

Authors:  Zhilin Guo; Mark L Brusseau
Journal:  Water Air Soil Pollut       Date:  2017-06-29       Impact factor: 2.520

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.