Literature DB >> 23246197

Reinforcing of QA/QC programs in radiotherapy departments in Croatia: results of treatment planning system verification.

Slaven Jurković1, Manda Svabić, Ana Diklić, Deni Smilović Radojčić, Dea Dundara, Mladen Kasabašić, Ana Ivković, Dario Faj.   

Abstract

Implementation of advanced techniques in clinical practice can greatly improve the outcome of radiation therapy, but it also makes the process much more complex with a lot of room for errors. An important part of the quality assurance program is verification of treatment planning system (TPS). Dosimetric verifications in anthropomorphic phantom were performed in 4 centers where new systems were installed. A total of 14 tests for 2 photon energies and multigrid superposition algorithms were conducted using the CMS XiO TPS. Evaluation criteria as specified in the International Atomic Energy Agency Technical Reports Series (IAEA TRS) 430 were employed. Results of measurements are grouped according to the placement of the measuring point and the beam energy. The majority of differences between calculated and measured doses in the water-equivalent part of the phantom were in tolerance. Significantly more out-of-tolerance values were observed in "nonwater-equivalent" parts of the phantom, especially for higher-energy photon beams. This survey was done as a part of continuous effort to build up awareness of quality assurance/quality control (QA/QC) importance in the Croatian radiotherapy community. Understanding the limitations of different parts of the various systems used in radiation therapy can systematically improve quality as well.
Copyright © 2013 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23246197     DOI: 10.1016/j.meddos.2012.07.008

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  2 in total

1.  Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry.

Authors:  Đeni Smilovic Radojcic; David Rajlic; Bozidar Casar; Manda Svabic Kolacio; Nevena Obajdin; Dario Faj; Slaven Jurkovic
Journal:  Radiol Oncol       Date:  2018-04-30       Impact factor: 2.991

2.  Dosimetric accuracy of three dose calculation algorithms for radiation therapy of in situ non-small cell lung carcinoma.

Authors:  Manda Švabić Kolacio; David Rajlić; Milan Radojčić; Đeni Smilović Radojčić; Nevena Obajdin; Dea Dundara Debeljuh; Slaven Jurković
Journal:  Rep Pract Oncol Radiother       Date:  2022-03-22
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.