Literature DB >> 23241569

Stair ascent with an innovative microprocessor-controlled exoprosthetic knee joint.

Malte Bellmann1, Thomas Schmalz, Eva Ludwigs, Siegmar Blumentritt.   

Abstract

Climbing stairs can pose a major challenge for above-knee amputees as a result of compromised motor performance and limitations to prosthetic design. A new, innovative microprocessor-controlled prosthetic knee joint, the Genium, incorporates a function that allows an above-knee amputee to climb stairs step over step. To execute this function, a number of different sensors and complex switching algorithms were integrated into the prosthetic knee joint. The function is intuitive for the user. A biomechanical study was conducted to assess objective gait measurements and calculate joint kinematics and kinetics as subjects ascended stairs. Results demonstrated that climbing stairs step over step is more biomechanically efficient for an amputee using the Genium prosthetic knee than the previously possible conventional method where the extended prosthesis is trailed as the amputee executes one or two steps at a time. There is a natural amount of stress on the residual musculoskeletal system, and it has been shown that the healthy contralateral side supports the movements of the amputated side. The mechanical power that the healthy contralateral knee joint needs to generate during the extension phase is also reduced. Similarly, there is near normal loading of the hip joint on the amputated side.

Entities:  

Mesh:

Year:  2012        PMID: 23241569     DOI: 10.1515/bmt-2011-0029

Source DB:  PubMed          Journal:  Biomed Tech (Berl)        ISSN: 0013-5585            Impact factor:   1.411


  7 in total

1.  Effects of sensory augmentation on postural control and gait symmetry of transfemoral amputees: a case description.

Authors:  Anna Pagel; Alejandro Hernandez Arieta; Robert Riener; Heike Vallery
Journal:  Med Biol Eng Comput       Date:  2015-12-31       Impact factor: 2.602

2.  Gait Training Interventions for Lower Extremity Amputees: A Systematic Literature Review.

Authors:  M Jason Highsmith; Casey R Andrews; Claire Millman; Ashley Fuller; Jason T Kahle; Tyler D Klenow; Katherine L Lewis; Rachel C Bradley; John J Orriola
Journal:  Technol Innov       Date:  2016-09-01

3.  EFFECTS OF THE GENIUM MICROPROCESSOR KNEE SYSTEM ON KNEE MOMENT SYMMETRY DURING HILL WALKING.

Authors:  M Jason Highsmith; Tyler D Klenow; Jason T Kahle; Matthew M Wernke; Stephanie L Carey; Rebecca M Miro; Derek J Lura
Journal:  Technol Innov       Date:  2016-09-01

4.  EFFECTS OF THE GENIUM KNEE SYSTEM ON FUNCTIONAL LEVEL, STAIR AMBULATION, PERCEPTIVE AND ECONOMIC OUTCOMES IN TRANSFEMORAL AMPUTEES.

Authors:  M Jason Highsmith; Jason T Kahle; Matthew M Wernke; Stephanie L Carey; Rebecca M Miro; Derek J Lura; Bryce S Sutton
Journal:  Technol Innov       Date:  2016-09-01

5.  Does a microprocessor-controlled prosthetic knee affect stair ascent strategies in persons with transfemoral amputation?

Authors:  Jennifer M Aldridge Whitehead; Erik J Wolf; Charles R Scoville; Jason M Wilken
Journal:  Clin Orthop Relat Res       Date:  2014-10       Impact factor: 4.176

6.  Maximum Swing Flexion or Gait Symmetry: A Comparative Evaluation of Control Targets on Metabolic Energy Expenditure of Amputee Using Intelligent Prosthetic Knee.

Authors:  Wujing Cao; Weiliang Zhao; Hongliu Yu; Wenming Chen; Qiaoling Meng
Journal:  Biomed Res Int       Date:  2018-11-21       Impact factor: 3.411

7.  Analysis of clinically important factors on the performance of advanced hydraulic, microprocessor-controlled exo-prosthetic knee joints based on 899 trial fittings.

Authors:  Andreas Hahn; Michael Lang; Claudia Stuckart
Journal:  Medicine (Baltimore)       Date:  2016-11       Impact factor: 1.889

  7 in total