Literature DB >> 2323977

Large scale optimization of beam weights under dose-volume restrictions.

M Langer1, R Brown, M Urie, J Leong, M Stracher, J Shapiro.   

Abstract

The problem of choosing weights for beams in a multifield plan which maximizes tumor dose under conditions that recognize the volume dependence of organ tolerance to radiation is considered, and its solution described. Structures are modelled as collections of discrete points, and the weighting problem described as a combinatorial linear program (LP). The combinatorial LP is solved as a mixed 0/1 integer program with appropriate restrictions on normal tissue dose. The method is illustrated through the assignment of weights to a set of 10 beams incident on a pelvic target. Dose-volume restrictions are placed on surrounding bowel, bladder, and rectum, and a limit placed on tumor dose inhomogeneity. Different tolerance restrictions are examined, so that the sensitivity of the target dose to changes in the normal tissue constraints may be explored. It is shown that the distributions obtained satisfy the posed constraints. The technique permits formal solution of the optimization problem, in a time short enough to meet the needs of treatment planners.

Entities:  

Mesh:

Year:  1990        PMID: 2323977     DOI: 10.1016/0360-3016(90)90413-e

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  9 in total

1.  Designing radiotherapy plans with elastic constraints and interior point methods.

Authors:  Allen Holder
Journal:  Health Care Manag Sci       Date:  2003-02

2.  Intensity modulated radiation therapy with field rotation--a time-varying fractionation study.

Authors:  Delal Dink; Mark P Langer; Ronald L Rardin; Joseph F Pekny; Gintaras V Reklaitis; Behlul Saka
Journal:  Health Care Manag Sci       Date:  2012-01-10

3.  Integrating soft and hard dose-volume constraints into hierarchical constrained IMRT optimization.

Authors:  Sovanlal Mukherjee; Linda Hong; Joseph O Deasy; Masoud Zarepisheh
Journal:  Med Phys       Date:  2019-12-04       Impact factor: 4.071

4.  An Automatic Approach for Satisfying Dose-Volume Constraints in Linear Fluence Map Optimization for IMPT.

Authors:  Maryam Zaghian; Gino Lim; Wei Liu; Radhe Mohan
Journal:  J Cancer Ther       Date:  2014-02

5.  Automated and Clinically Optimal Treatment Planning for Cancer Radiotherapy.

Authors:  Masoud Zarepisheh; Linda Hong; Ying Zhou; Qijie Huang; Jie Yang; Gourav Jhanwar; Hai D Pham; Pinar Dursun; Pengpeng Zhang; Margie A Hunt; Gig S Mageras; Jonathan T Yang; Yoshiya Yamada; Joseph O Deasy
Journal:  INFORMS J Appl Anal       Date:  2022-02-01

6.  Reduced-order constrained optimization in IMRT planning.

Authors:  Renzhi Lu; Richard J Radke; Jie Yang; Laura Happersett; Ellen Yorke; Andrew Jackson
Journal:  Phys Med Biol       Date:  2008-11-07       Impact factor: 3.609

7.  A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy.

Authors:  Jaeman Son; Taesung Baek; Boram Lee; Dongho Shin; Sung Yong Park; Jeonghoon Park; Young Kyung Lim; Se Byeong Lee; Jooyoung Kim; Myonggeun Yoon
Journal:  Radiol Oncol       Date:  2015-08-21       Impact factor: 2.991

8.  Feasibility study on the verification of actual beam delivery in a treatment room using EPID transit dosimetry.

Authors:  Tae Seong Baek; Eun Ji Chung; Jaeman Son; Myonggeun Yoon
Journal:  Radiat Oncol       Date:  2014-12-04       Impact factor: 3.481

9.  A new homogeneity index based on statistical analysis of the dose-volume histogram.

Authors:  Myonggeun Yoon; Sung Yong Park; Dongho Shin; Se Byeong Lee; Hong Ryull Pyo; Dae Yong Kim; Kwan Ho Cho
Journal:  J Appl Clin Med Phys       Date:  2007-03-20       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.