Literature DB >> 23228946

Prevention of tunneled cuffed hemodialysis catheter-related dysfunction and bacteremia by a neutral-valve closed-system connector: a single-center randomized controlled trial.

Florence Bonkain1, Judith Racapé, Isabelle Goncalvez, Micheline Moerman, Olivier Denis, Nadia Gammar, Karine Gastaldello, Joëlle L Nortier.   

Abstract

BACKGROUND: Hemodialysis (HD) tunneled cuffed catheters may be fitted with neutral-valve closed-system connectors. Such connectors, which are flushed with saline solution and used for 3 consecutive HD sessions, provide a mechanically closed positive-pressure barrier and potentially may be useful to prevent catheter-related bacteremia and dysfunction. STUDY
DESIGN: Single-center randomized controlled trial. SETTING & PARTICIPANTS: 66 adult HD patients with a tunneled cuffed catheter. INTERVENTION: Neutral-valve closed-system connector (Tego Needlefree Hemodialysis Connector) versus trisodium citrate, 46.7%, locking solution (Citra-Lock; control group). OUTCOMES: Primary composite outcome was the incidence rate of catheter-related dysfunction or bacteremia. Secondary outcomes were the separate incidence rates of catheter-related dysfunction and bacteremia and the cost of both procedures. MEASUREMENTS: Catheter dysfunction was defined as the requirement of urokinase and/or a mean blood flow ≤250 mL/min during 2 consecutive HD sessions. Catheter-related bacteremia was defined as ≥2 positive blood cultures. Time of catheter use was calculated and the incidence rate of complications was expressed per 100 person-years.
RESULTS: 66 patients were followed up for a median of 86 (IQR, 29-200) days. The composite primary outcome was not significantly reduced in the closed-system-connector intervention group versus the citrate-locking-solution control group (63.56 vs 71.51 per 100 person-years; P = 0.3). Catheter dysfunction in the intervention group was not decreased versus controls (59.59 vs 51.64 per 100-person-years; P = 0.9). Only 6 catheter-related bacteremia events were identified, one in the intervention group (3.97 vs 19.86 per 100 person-years; P = 0.06). LIMITATIONS: Small size of the patient population and single-center study.
CONCLUSIONS: Superiority of the closed-system connector in terms of prevention of the primary efficacy end point compared to the standard locking solution was not observed. Further evaluation in a larger study is suggested.
Copyright © 2013 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23228946     DOI: 10.1053/j.ajkd.2012.10.014

Source DB:  PubMed          Journal:  Am J Kidney Dis        ISSN: 0272-6386            Impact factor:   8.860


  5 in total

1.  The Tego™ needleless connector for hemodialysis catheters may protect against catheter colonization.

Authors:  M Guembe; M J Pérez-Granda; R Cruces; L Alcalá; E Bouza
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-05-17       Impact factor: 3.267

2.  Cuffed-tunneled hemodialysis catheter survival and complications in pediatric patients: a single-center data analysis in China.

Authors:  Kai Wang; Pei Wang; Xian-Hui Liang; Fang-Fang Yuan; Zhang-Suo Liu
Journal:  Int J Clin Exp Med       Date:  2015-06-15

Review 3.  Anticoagulants and antiplatelet agents for preventing central venous haemodialysis catheter malfunction in patients with end-stage kidney disease.

Authors:  Ying Wang; Jessica N Ivany; Vlado Perkovic; Martin P Gallagher; Mark Woodward; Meg J Jardine
Journal:  Cochrane Database Syst Rev       Date:  2016-04-04

Review 4.  Prevention of Bloodstream Infections in Patients Undergoing Hemodialysis.

Authors:  Molly Fisher; Ladan Golestaneh; Michael Allon; Kenneth Abreo; Michele H Mokrzycki
Journal:  Clin J Am Soc Nephrol       Date:  2019-12-05       Impact factor: 8.237

5.  Use of the Tego needlefree connector is associated with reduced incidence of catheter-related bloodstream infections in hemodialysis patients.

Authors:  Steven M Brunelli; Levi Njord; Abigail E Hunt; Scott P Sibbel
Journal:  Int J Nephrol Renovasc Dis       Date:  2014-04-03
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.