A comparison of the use of traditional hand injection versus automated contrast injectors during cardiac catheterization.

Robert W Godley1, Kruti Joshi, Jeffrey A Breall.   

Abstract

OBJECTIVE: To compare the incidence of contrast-induced nephropathy (CIN) and vascular complications in patients undergoing cardiac catheterization using traditional manual contrast injection techniques with those in which an automated contrast injector device was used.
BACKGROUND: It has been suggested that use of automated contrast injectors in coronary interventions could reduce complications by reducing contrast volume usage and allowing the use of smaller sheaths.
METHODS: This was a retrospective cohort study with review of patient's electronic medical charts and the Heartbase registry. Complete data were available for 13107 patients between 1999 and 2009. Of those patients, 5137 procedures were performed with traditional manual contrast injection and 7970 procedures used automated contrast injection. The CIN event rate and vascular complication rates were compared between patients who underwent catheterization using these differing techniques.
RESULTS: Overall, the incidence of CIN was comparable in traditional and automated contrast injector assisted catheterizations (9.07% vs 8.73%; P=.5). However, for the subgroup of patients that had a diagnostic cardiac catheterization and went on to have an ad hoc angioplasty, incidence of CIN was much lower in the automated contrast injector group (7.04% vs 5.50%; P=.007). The incidence of vascular complications was lower in the automated contrast injector group vs the traditional method (2.85% vs 2.17%; P=.02), irrespective of an ad hoc angioplasty.
CONCLUSION: Use of automated contrast injectors resulted in a significant decrease in vascular complications across all cardiac catheterizations. Additionally, there was a significant decrease in CIN when the automated contrast injector was used for catheterizations that included a percutaneous coronary intervention.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23220975

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  4 in total

Review 1.  Meta-analysis of the effect of automated contrast injection devices versus manual injection and contrast volume on risk of contrast-induced nephropathy.

Authors:  Kristopher D Minsinger; Hayah M Kassis; Clay A Block; Mandeep Sidhu; Jeremiah R Brown
Journal:  Am J Cardiol       Date:  2013-10-03       Impact factor: 2.778

2.  A prospective study of contrast preservation using ultra-low contrast delivery technique versus standard automated contrast injector system in coronary procedures.

Authors:  Adam Stys; Maheedhar Gedela; Udit Bhatnagar; Marian Petrasko; Hazem Dawoud; Tadeusz Malinski; Tomasz Stys
Journal:  Indian Heart J       Date:  2019-09-10

3.  Contrast Media Injector Technology - Renal Safety During Coronarography.

Authors:  Ermina Mujicic; Ekrem Kevric; Senija Rasic; Amina Selimovic; Nermir Granov; Dinka Music
Journal:  Acta Inform Med       Date:  2015-10-05

4.  Iatrogenic propagation of coronary dissection during diagnostic coronary angiography: an uncommon but important procedural consideration.

Authors:  Chirag K Desai; Udit Bhatnagar; Adam Stys; Orvar Jonsson
Journal:  BMJ Case Rep       Date:  2017-12-14