Mechanical revascularization of acute iatrogenic anterior cerebral artery occlusions: use of a new coaxial dual-lumen balloon catheter results in rapid access and flow restoration.

Robert F James1, John Richard Lamm, Hilal A Kanaan.   

Abstract

Acute iatrogenic occlusion of cerebral vessels is a risk during the performance of neuroendovascular procedures. Most commonly this is a result of thrombus formation within the vessel, thromboembolism or an acute vasospastic response. There are several options for flow restoration including pharmacological, mechanical and microsurgical. Mechanical flow restoration, usually by thrombectomy, is typically performed in large cerebral vessels. Current mechanical thrombectomy devices have limited utility in smaller vessels that are more difficult to access, such as the anterior cerebral artery (ACA). We present two cases where successful flow restoration of an intraoperative acutely occluded or thrombotic ACA was rapidly achieved by balloon dilation using a new coaxial dual-lumen balloon catheter. The time elapsed from the decision to use the balloon catheter until revascularization for each patient was 5 min and 46 s (case 1) and 10 min and 25 s (case 2).

Entities:  

Mesh:

Year:  2012        PMID: 23220444      PMCID: PMC4545122          DOI: 10.1136/bcr-2012-010545

Source DB:  PubMed          Journal:  BMJ Case Rep        ISSN: 1757-790X


  10 in total

1.  Ascent™: a novel balloon microcatheter device used as the primary coiling microcatheter of a basilar tip aneurysm.

Authors:  Jawad F Kirmani; Ugo Paolucci
Journal:  J Neuroimaging       Date:  2011-06-24       Impact factor: 2.486

2.  Percutaneous balloon angioplasty for acute occlusion of intracranial arteries.

Authors:  Koji Tokunaga; Kenji Sugiu; Kimihiro Yoshino; Yoshinori Terai; Takashi Imaoka; Akira Handa; Nobuyuki Hirotsune; Noboru Kusaka; Isao Date
Journal:  Neurosurgery       Date:  2010-09       Impact factor: 4.654

3.  Transarterial balloon assisted Onyx embolization of pericallosal arteriovenous malformations.

Authors:  Ludwig D Orozco; Gustavo D Luzardo; Razvan F Buciuc
Journal:  J Neurointerv Surg       Date:  2012-06-22       Impact factor: 5.836

4.  Use of a new double-lumen balloon catheter for single-catheter balloon-assisted coil embolization of intracranial aneurysms: technical note.

Authors:  Bryan Pukenas; Felipe C Albuquerque; John B Weigele; Robert W Hurst; Michael F Stiefel
Journal:  Neurosurgery       Date:  2011-09       Impact factor: 4.654

5.  Endovascular treatment of acute embolism of the major cerebral arteries. The value of balloon disruption of the embolus.

Authors:  S Ota; T Ota; K Goto; I Inoue; T Ota
Journal:  Interv Neuroradiol       Date:  2005-01-05       Impact factor: 1.610

Review 6.  Balloon assisted treatment of intracranial aneurysms: the conglomerate coil mass technique.

Authors:  D Fiorella; H H Woo
Journal:  J Neurointerv Surg       Date:  2009-10-30       Impact factor: 5.836

7.  Abciximab for treatment of thromboembolic complications during endovascular coiling of intracranial aneurysms.

Authors:  R G Jones; I Davagnanam; S Colley; R J West; D A Yates
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-10       Impact factor: 3.825

8.  Intraarterial abciximab for treatment of thromboembolism during coil embolization of intracranial aneurysms: outcome and fatal hemorrhagic complications.

Authors:  Jae Hyo Park; Jeong Eun Kim; Seung Hun Sheen; Cheol Kyu Jung; Bae Ju Kwon; O-Ki Kwon; Chang Wan Oh; Moon Hee Han; Dae Hee Han
Journal:  J Neurosurg       Date:  2008-03       Impact factor: 5.115

9.  Mechanical thrombectomy for acute ischemic stroke: final results of the Multi MERCI trial.

Authors:  Wade S Smith; Gene Sung; Jeffrey Saver; Ronald Budzik; Gary Duckwiler; David S Liebeskind; Helmi L Lutsep; Marilyn M Rymer; Randall T Higashida; Sidney Starkman; Y Pierre Gobin; Donald Frei; Thomas Grobelny; Frank Hellinger; Dan Huddle; Chelsea Kidwell; Walter Koroshetz; Michael Marks; Gary Nesbit; Isaac E Silverman
Journal:  Stroke       Date:  2008-02-28       Impact factor: 7.914

10.  Initial experience with the coaxial dual-lumen ascent balloon catheter for wide-neck aneurysm coil embolization.

Authors:  Marc A Lazzaro; Ziad Darkhabani; Osama O Zaidat; Brian-Fred M Fitzsimmons
Journal:  Front Neurol       Date:  2011-08-19       Impact factor: 4.003