Rapid calculation of standardized placental volume at 11 to 13 weeks and the prediction of small for gestational age babies.

Sally L Collins1, Gordon N Stevenson, J Alison Noble, Lawrence Impey.   

Abstract

Fetal growth restriction is one of the greatest risk factors for stillbirth. This pilot cohort study examined whether rapid placental volume (PlaV) calculation at 11 to 13 + 6 weeks can predict the small for gestational age (cSGA) baby. Women with singleton pregnancies were recruited (N = 145), a static three-dimensional (3-D) volume was captured, and the placental volume was computed using a semi-automated technique. Regression analysis explored the relationships between customized birth weight, placental quotient (PQ), standardized placental volume (sPlaV), and other predictors of SGA (including pregnancy-associated protein and uterine artery pulsatility index (PI). The results were examined using receiver-operating characteristic (ROC) curve analysis in the total population and then in the 2 subgroups whose members were classified as low risk or high risk at booking. Both PQ and sPlaV were significantly different for cSGA pregnancies compared to appropriate for gestational age (AGA) babies (p = 0.003 and <0.001, respectively) but only sPlaV was normally distributed. The independent predictors of birth weight (sPlaV, pregnancy associated protein, and nuchal translucency) were combined to produce a predictive model for cSGA. The ROC curves for prediction of cSGA in all 143 women gave areas under the curve of 0.77 (0.66 to 0.87) for sPlaV alone and 0.80 (0.69 to 0.92) for the combined model. When this was applied to the low-risk group, the areas under the curve were 0.82 (0.69 to 0.94) and 0.84 (0.72 to 0.95), respectively. For the high-risk group, the areas under the curve were 0.67 (0.45 to 0.86) for sPlaV alone and 0.76 (0.55 to 0.96) for the combined model. The use of this rapid-image analysis technique and dimensionless index to correct for gestation brings the possibility of an early combined screening test for the cSGA baby a step closer.
Copyright © 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23219036     DOI: 10.1016/j.ultrasmedbio.2012.09.003

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  11 in total

1.  Multiscale modelling of the feto-placental vasculature.

Authors:  A R Clark; M Lin; M Tawhai; R Saghian; J L James
Journal:  Interface Focus       Date:  2015-04-06       Impact factor: 3.906

2.  Fully automated, real-time 3D ultrasound segmentation to estimate first trimester placental volume using deep learning.

Authors:  Pádraig Looney; Gordon N Stevenson; Kypros H Nicolaides; Walter Plasencia; Malid Molloholli; Stavros Natsis; Sally L Collins
Journal:  JCI Insight       Date:  2018-06-07

3.  User-Guided Segmentation of Multi-modality Medical Imaging Datasets with ITK-SNAP.

Authors:  Paul A Yushkevich; Artem Pashchinskiy; Ipek Oguz; Suyash Mohan; J Eric Schmitt; Joel M Stein; Dženan Zukić; Jared Vicory; Matthew McCormick; Natalie Yushkevich; Nadav Schwartz; Yang Gao; Guido Gerig
Journal:  Neuroinformatics       Date:  2019-01

Review 4.  Placental Origins of Chronic Disease.

Authors:  Graham J Burton; Abigail L Fowden; Kent L Thornburg
Journal:  Physiol Rev       Date:  2016-10       Impact factor: 37.312

5.  Minimally interactive placenta segmentation from three-dimensional ultrasound images.

Authors:  Ipek Oguz; Natalie Yushkevich; Alison Pouch; Baris U Oguz; Jiancong Wang; Shobhana Parameshwaran; James Gee; Paul A Yushkevich; Nadav Schwartz
Journal:  J Med Imaging (Bellingham)       Date:  2020-02-22

6.  A retrospective segmentation analysis of placental volume by magnetic resonance imaging from first trimester to term gestation.

Authors:  Rachel L León; Kevin T Li; Brandon P Brown
Journal:  Pediatr Radiol       Date:  2018-07-20

7.  Combining early (<11 weeks' gestation) ultrasound features and maternal factors to predict small-for-gestational age neonates.

Authors:  Tracey J Hanchard; Bradley S de Vries; Ann E Quinton; Michael Sinosich; Jonathan A Hyett
Journal:  Australas J Ultrasound Med       Date:  2020-08-20

8.  Fully Automated Placental Volume Quantification From 3D Ultrasound for Prediction of Small-for-Gestational-Age Infants.

Authors:  Nadav Schwartz; Ipek Oguz; Jiancong Wang; Alison Pouch; Natalie Yushkevich; Shobhana Parameshwaran; James Gee; Paul Yushkevich; Baris Oguz
Journal:  J Ultrasound Med       Date:  2021-09-23       Impact factor: 2.754

9.  Chronic Protein Restriction in Mice Impacts Placental Function and Maternal Body Weight before Fetal Growth.

Authors:  Paula N Gonzalez; Malgorzata Gasperowicz; Jimena Barbeito-Andrés; Natasha Klenin; James C Cross; Benedikt Hallgrímsson
Journal:  PLoS One       Date:  2016-03-28       Impact factor: 3.240

Review 10.  First trimester biomarkers in the prediction of later pregnancy complications.

Authors:  Stefan C Kane; Fabricio da Silva Costa; Shaun Brennecke
Journal:  Biomed Res Int       Date:  2014-03-30       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.