Stent graft performance in the treatment of abdominal aortic aneurysms: the influence of compliance and geometry.

Liam Morris1, Florian Stefanov, Tim McGloughlin.   

Abstract

The long-term success of the endovascular procedure for the treatment of Abdominal Aortic Aneurysms (AAAs ) depends on the secure fixation of the proximal end and the geometry of the stent-graft (SG) device. Variations in SG types can affect proximal fixation and SG hemodynamics. Such hemodynamic variations can have a catastrophic effect on the vascular system and may result from a SG/arterial wall compliance mismatch and the sudden decrease in cross-sectional area at the bifurcation, which may result in decreased distal perfusion, increased pressure wave reflection and increased stress at the interface between the stented and non-stented portion of the vessel. To examine this compliance mismatch, a commercial SG device was tested experimentally under a physiological pressure condition in a silicone AAA model based on computed tomography scans. There was a considerable reduction in compliance of 54% and an increase in the pulse wave velocity of 21%, with a significant amount of the forward pressure wave being reflected. To examine the SG geometrical effects, a commercial bifurcated geometry was compared computationally and experimentally with a geometrical taper in the form of a blended section, which provided a smooth transition from the proximal end to both iliac legs. The sudden contraction of commercial SG at the bifurcation region causes flow separation within the iliac legs, which is known to cause SG occlusion and increased proximal pressure. The blended section along the bifurcation region promotes a greater uniformity of the fluid flow field within the distal legs, especially, during the deceleration phase with reduced boundary layer reversal. In order to reduce the foregoing losses, abrupt changes of cross-section should be avoided. Geometrical tapers could lead to improved clinical outcomes for AAA SGs.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23218139     DOI: 10.1016/j.jbiomech.2012.11.026

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  8 in total

Review 1.  Arterial Stiffness Alterations and Inflammatory Response Following Endovascular Aortic Repair: Based on a Presentation at the 2013 VEITH Symposium, November 19-23, 2013 (New York, NY, USA).

Authors:  Konstantinos G Moulakakis; Spyridon N Mylonas; John Kakisis; Nikolaos P E Kadoglou; Ioannis Papadakis; George S Sfyroeras; Constantine C N Antonopoulos; George Mantas; Ignatios Ikonomidis; Christos D Liapis
Journal:  Aorta (Stamford)       Date:  2015-04-01

2.  Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones.

Authors:  Ying Guan; Lu Wang; Jing Lin; Martin W King
Journal:  Materials (Basel)       Date:  2016-08-05       Impact factor: 3.623

3.  Pulsatile Flow-Induced Fatigue-Resistant Photopolymerizable Hydrogels for the Treatment of Intracranial Aneurysms.

Authors:  Oriane Poupart; Riccardo Conti; Andreas Schmocker; Lucio Pancaldi; Christophe Moser; Katja M Nuss; Mahmut S Sakar; Tomas Dobrocky; Hansjörg Grützmacher; Pascal J Mosimann; Dominique P Pioletti
Journal:  Front Bioeng Biotechnol       Date:  2021-01-20

4.  Influence of shape-memory stent grafts on local aortic compliance.

Authors:  J Concannon; K M Moerman; N Hynes; S Sultan; J P McGarry
Journal:  Biomech Model Mechanobiol       Date:  2021-09-19

5.  An in vitro Assessment of the Haemodynamic Features Occurring Within the True and False Lumens Separated by a Dissection Flap for a Patient-Specific Type B Aortic Dissection.

Authors:  Liam Morris; Paul Tierney; Niamh Hynes; Sherif Sultan
Journal:  Front Cardiovasc Med       Date:  2022-03-17

6.  Non-Invasive Pulse Wave Analysis in a Thrombus-Free Abdominal Aortic Aneurysm after Implantation of a Nitinol Aortic Endograft.

Authors:  Efstratios Georgakarakos; Christos Argyriou; George S Georgiadis; Miltos K Lazarides
Journal:  Front Surg       Date:  2016-01-11

7.  Numerical and Experimental Investigation of Novel Blended Bifurcated Stent Grafts with Taper to Improve Hemodynamic Performance.

Authors:  Ming Liu; Zhenze Wang; Anqiang Sun; Xiaoyan Deng
Journal:  Comput Math Methods Med       Date:  2018-09-09       Impact factor: 2.238

8.  Efficiently Simulating an Endograft Deployment: A Methodology for Detailed CFD Analyses.

Authors:  Faidon Kyriakou; Craig Maclean; William Dempster; David Nash
Journal:  Ann Biomed Eng       Date:  2020-05-11       Impact factor: 3.934

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.