A method to determine suitable fluoroscopic projections for transcatheter aortic valve implantation by computed tomography.

Martin Arnold1, Stephan Achenbach, Ina Pfeiffer, Stephan Ensminger, Mohamed Marwan, Friedrich Einhaus, Tobias Pflederer, Dieter Ropers, Annika Schuhbaeck, Katharina Anders, Michael Lell, Michael Uder, Josef Ludwig, Michael Weyand, Werner G Daniel, Richard Feyrer.   

Abstract

BACKGROUND: In transcatheter aortic valve implantation (TAVI), optimal selection of fluoroscopic projections that permit orthogonal visualization of the aortic valve plane is important but may be difficult to achieve.
OBJECTIVE: We developed and validated a simple method to predict suitable fluoroscopic projections on the basis of cardiac CT datasets.
METHODS: In 75 consecutive patients that underwent TAVI, angulations in which a 35-mm thick maximum intensity projection would render all aortic valve calcium into 1 plane were determined by manual interaction with contrast-enhanced dual-source CT datasets. TAVI operators used the predicted angulation for the first aortic angiogram and performed additional aortic angiograms if no satisfactory view of the aortic valve plane was obtained. Predicted angulations were compared with the angulation used for valve implantation. Radiation exposure and contrast use was compared between patients with accurate prediction of fluoroscopic angulations by CT and patients in whom CT failed to predict a suitable view.
RESULTS: The mean difference between the predicted angulation according to CT and the angulation used for implantation was 3 ± 6 degrees. CT predicted a suitable angulation (<5-degree deviation) in 63 of 75 cases (84%). The mean number of aortic angiograms acquired in patients with correct prediction (1.02 ± 0.1) was significantly lower than in patients with incorrect prediction of the implantation angle by CT (3.0 ± 1.7; P < 0.001). Contrast agent required for the entire TAVI procedure was lower in patients with correct prediction (72 ± 36 mL vs 106 ± 39 mL; P = 0.001).
CONCLUSION: CT permits prediction of suitable angulations for TAVI in most cases.
Copyright © 2012 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23217463     DOI: 10.1016/j.jcct.2012.10.008

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  17 in total

Review 1.  Role of Cardiac CT Before Transcatheter Aortic Valve Implantation (TAVI).

Authors:  Mohamed Marwan; Stephan Achenbach
Journal:  Curr Cardiol Rep       Date:  2016-02       Impact factor: 2.931

Review 2.  DNA transposons in vertebrate functional genomics.

Authors:  C Miskey; Z Izsvák; K Kawakami; Z Ivics
Journal:  Cell Mol Life Sci       Date:  2005-03       Impact factor: 9.261

Review 3.  Transcatheter aortic valve insertion (TAVI): a review.

Authors:  B Clayton; G Morgan-Hughes; C Roobottom
Journal:  Br J Radiol       Date:  2013-11-20       Impact factor: 3.039

Review 4.  [Aortic valve stenosis: computed tomography prior to transcatheter aortic valve implantation (TAVI). How can the outcome be improved?].

Authors:  M Hell; S Achenbach; M Arnold
Journal:  Herz       Date:  2015-06       Impact factor: 1.443

Review 5.  CT support of cardiac structural interventions.

Authors:  Michaela M Hell; Stephan Achenbach
Journal:  Br J Radiol       Date:  2019-03-11       Impact factor: 3.039

6.  Reproducibility of aortic annulus measurements by computed tomography.

Authors:  Annika Schuhbaeck; Stephan Achenbach; Tobias Pflederer; Mohamed Marwan; Jasmin Schmid; Holger Nef; Johannes Rixe; Franziska Hecker; Christian Schneider; Michael Lell; Michael Uder; Martin Arnold
Journal:  Eur Radiol       Date:  2014-05-22       Impact factor: 5.315

Review 7.  [Imaging in structural heart disease : Impact on interventional therapy].

Authors:  A Schmermund; J Eckert; S N Schelle; H Eggebrecht
Journal:  Herz       Date:  2016-11       Impact factor: 1.443

8.  Personalized Fluoroscopic Angles in Watchman™ Left Atrial Appendage Closure Landing Zone Assessment: A Three-Dimensional Printed Simulation Study.

Authors:  Vikram Shee; Liwei He; Shenrong Liu; Xingfu Huang; Yanyu Chen; Liangzhen Xie; Xiaojiang Deng; Jian Peng
Journal:  Cureus       Date:  2020-06-23

Review 9.  The Role of Multimodality Imaging in Transcatheter Aortic Valve Replacement.

Authors:  Qi Liu; Rebecca T Hahn
Journal:  Curr Cardiol Rep       Date:  2019-07-19       Impact factor: 2.931

10.  Computed Tomography for Structural Heart Disease and Interventions.

Authors:  Pascal Thériault-Lauzier; Marco Spaziano; Beatriz Vaquerizo; Jean Buithieu; Giuseppe Martucci; Nicolo Piazza
Journal:  Interv Cardiol       Date:  2015-09
View more