| Literature DB >> 23204620 |
S Chandel1, C R Barhate, A R Srivastava, S R Kulkarni, S K Kulkarni, C J Kapadia.
Abstract
A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the estimation of tenoxicam in the microemulsion gels. Tenoxicam was chromatographed on silica gel 60 F(254) TLC plate, as a stationary phase. The mobile phase was toluene: ethyl acetate: formic acid (6:4:0.3 v/v/v), which gave a dense and compact spot of tenoxicam with a R(f) value of 0.38±0.03. The quantification was carried out at 379 nm. The method was validated in terms of linearity, accuracy, precision and specificity. To justify the suitability, accuracy and precision of the proposed method, recovery studies were performed at three concentration levels. Statistical analysis proved that the proposed method is accurate and reproducible with linearity in the range of 100 to 400 ng. The limit of detection and limit of quantification for tenoxicam were 25 and 50 μg/spot, respectively. The proposed method can be employed for the routine analysis of tenoxicam as well as in pharmaceutical formulations.Entities:
Keywords: Gel; HPTLC-desitometry; microemulsion; tenoxicam; validation
Year: 2012 PMID: 23204620 PMCID: PMC3507343 DOI: 10.4103/0250-474X.102541
Source DB: PubMed Journal: Indian J Pharm Sci ISSN: 0250-474X Impact factor: 0.975
Fig. 1Chemical structure of tenoxicam
Fig. 2Three dimentional overlay of HPTLC densitograms of standard plot of tenoxicam.
Analysis was done using 60F-254 TLC plates as stationery phase and toluene-ethyl acetate-formic acid (6:4:0.3, v/v/v) as mobile phase.
LINEAR REGRESSION DATA FOR THE CALIBRATION CURVES
Fig. 3Linear regression curve of the tenoxicam standard plot
The regression coefficient was found to be r2= 0.9978 for the equation y=18.481x-14.712
Fig. 4Overlay of HPTLC densitograms of (a) Tenoxicam standard, (b) Formulation I, (c) Formulation II, (d) Formulation III.
Analysis was done using 60F-254 TLC plates as stationery phase and toluene-ethyl acetate-formic acid (6:4:0.3, v/v/v) as mobile phase
RECOVERY STUDIES OF TENOXICAM FROM MICROEMULSION GELS
INSTRUMENTAL PRECISION AND ACCURACY DATA
ACCURACY RESULTS OF THE ASSAY
PRECISION DATA OF HPTLC ASSAY FOR TENOXICAM