| Literature DB >> 23199736 |
I Ieropoulos1, A Gálvez, J Greenman.
Abstract
The effects of adding sulphate in: (i) standard activated sludge microbial fuel cells (MFCs) and (ii) larger-scale leachate-treating columns - both as individual units and as a system connected in cascade - are reported. S-replete power output was ∼2-fold higher than that of the S-deplete MFC. Furthermore, the effects of evolved sulphide (S(2-)) inhibition were investigated. The overall decrease in power output from the sulphide inhibitor (Na(2)MoO(4)) additions was 83% for the S-replete and 90% for the S-deplete. The second phase with the leachate treating units shows an improvement of 32-86% (depended on leachate strength) in current output as a result of adding sulphate. When leachate column MFCs were connected fluidically in series, the amount of Na(2)SO(4) made available downstream was decreasing (increase in power was 99%, 40% and 12% for columns in cascade). Results demonstrated the beneficial effects of added sulphur sources to both activated sludge and leachate-treating MFCs.Entities:
Mesh:
Substances:
Year: 2012 PMID: 23199736 DOI: 10.1016/j.enzmictec.2012.10.002
Source DB: PubMed Journal: Enzyme Microb Technol ISSN: 0141-0229 Impact factor: 3.493