Literature DB >> 23199248

Identifying causes of laboratory turnaround time delay in the emergency department.

Mohammad Jalili1, Keivan Shalileh, Ali Mojtahed, Mohammad Mojtahed, Maziar Moradi-Lakeh.   

Abstract

BACKGROUND: Laboratory turnaround time (TAT) is an important determinant of patient stay and quality of care. Our objective is to evaluate laboratory TAT in our emergency department (ED) and to generate a simple model for identifying the primary causes for delay.
METHODS: We measured TATs of hemoglobin, potassium, and prothrombin time tests requested in the ED of a tertiary-care, metropolitan hospital during a consecutive one-week period. The time of different steps (physician order, nurse registration, blood-draw, specimen dispatch from the ED, specimen arrival at the laboratory, and result availability) in the test turnaround process were recorded and the intervals between these steps (order processing, specimen collection, ED waiting, transit, and within-laboratory time) and total TAT were calculated. Median TATs for hemoglobin and potassium were compared with those of the 1990 Q-Probes Study (25 min for hemoglobin and 36 min for potassium) and its recommended goals (45 min for 90% of tests). Intervals were compared according to the proportion of TAT they comprised.
RESULTS: Median TATs (170 min for 132 hemoglobin tests, 225 min for 172 potassium tests, and 195.5 min for 128 prothrombin tests) were drastically longer than Q-Probes reported and recommended TATs. The longest intervals were ED waiting time and order processing.
CONCLUSIONS: Laboratory TAT varies among institutions, and data are sparse in developing countries. In our ED, actions to reduce ED waiting time and order processing are top priorities. We recommend utilization of this model by other institutions in settings with limited resources to identify their own priorities for reducing laboratory TAT.

Entities:  

Mesh:

Year:  2012        PMID: 23199248     DOI: 0121512/AIM.008

Source DB:  PubMed          Journal:  Arch Iran Med        ISSN: 1029-2977            Impact factor:   1.354


  8 in total

1.  Speeding up laboratory test reporting in Medical Emergency and Cardiac Arrest calls: a quality improvement project.

Authors:  Mohammed Al-Talib; Isla Leslie
Journal:  BMJ Qual Improv Rep       Date:  2017-02-02

2.  Greater Efficiency Observed 12 Months Post-Implementation of an Automatic Tube Sorting and Registration System in a Core Laboratory.

Authors:  Fatma Ucar; Gonul Erden; Mine Yavuz Taslipinar; Gulfer Ozturk; Zeynep Ginis; Erdem Bulut; Namik Delibas
Journal:  J Med Biochem       Date:  2015-12-30       Impact factor: 3.402

3.  Weekly laboratory turn-around time identifies poor performance masked by aggregated reporting.

Authors:  Lindi-Marie Coetzee; Naseem Cassim; Deborah K Glencross
Journal:  Afr J Lab Med       Date:  2020-12-21

4.  Evaluation of Laboratory Performance, Associated Factors and Staff Awareness Towards Achieving Turnaround Time in Tertiary Hospitals, Ethiopia.

Authors:  Mebrat Gebreyes; Abay Sisay; Dilargachew Tegen; Abushet Asnake; Mistire Wolde
Journal:  Ethiop J Health Sci       Date:  2020-09

5.  In-depth investigation of turn-around time of full blood count tests requested from a clinical haematology outpatient department in Cape Town, South Africa.

Authors:  Leonard Mutema; Zivanai Chapanduka; Fungai Musaigwa; Nomusa Mashigo
Journal:  Afr J Lab Med       Date:  2021-04-29

6.  Point-of-care high-sensitivity assay on PATHFAST as the backup in the emergency room.

Authors:  Joško Osredkar; Katja Krivic; Teja Fabjan; Kristina Kumer; Jure Tršan; Laura Poljančič; Petra Finderle; Hugon Možina
Journal:  Med Access Point Care       Date:  2021-10-26

7.  Emergency department quality and safety indicators in resource-limited settings: an environmental survey.

Authors:  Emily L Aaronson; Regan H Marsh; Moytrayee Guha; Jeremiah D Schuur; Shada A Rouhani
Journal:  Int J Emerg Med       Date:  2015-10-31

8.  Reducing delay in laboratory reports for outpatients from 16% to <3% at a non-profit hospital in New Delhi, India.

Authors:  Saru Bhartia; Pradaya Wahi; Rinu Goyal
Journal:  BMJ Open Qual       Date:  2019-10-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.