Literature DB >> 2319100

Skin blade versus deep blade: a vehicle of contamination in podiatric surgery.

V B Cibella1, L Smith, M Haas, A Green, J Stewart.   

Abstract

A total of 166 surgical blades consisting of control blades, skin blades, and deep blades were cultured from 50 elective podiatric surgical cases. Five blades from four cases cultured Staphylococcus epidermidis. The practice of changing from skin blade to deep blade to reduce contamination of a clean surgical wound is not supported by the data obtained in this study.

Entities:  

Mesh:

Year:  1990        PMID: 2319100

Source DB:  PubMed          Journal:  J Foot Surg        ISSN: 0449-2544


  2 in total

1.  Outcome following deep wound contamination in cemented arthroplasty.

Authors:  A M Byrne; S Morris; T McCarthy; W Quinlan; J M O'byrne
Journal:  Int Orthop       Date:  2006-04-04       Impact factor: 3.075

Review 2.  Myths and legends in orthopaedic practice: are we all guilty?

Authors:  Nirmal C Tejwani; Igor Immerman
Journal:  Clin Orthop Relat Res       Date:  2008-08-26       Impact factor: 4.176

  2 in total