Literature DB >> 23188562

Comparison of breathhold, navigator-triggered, and free-breathing diffusion-weighted MRI for focal hepatic lesions.

Ji Soo Choi1, Myeong-Jin Kim, Yong Eun Chung, Kyung Ah Kim, Jin-Young Choi, Joon Seok Lim, Mi-Suk Park, Ki Whang Kim.   

Abstract

PURPOSE: To compare the breathhold, navigator-triggered, and free-breathing techniques in diffusion-weighted magnetic resonance imaging (MRI) for the evaluation of focal liver lesions on a 3.0T system.
MATERIALS AND METHODS: Fifty-two patients (36 men, 16 women; mean age, 56.4 years) with focal liver lesions underwent breathhold, navigator-triggered, and free-breathing diffusion-weighted imaging (DWI) of the liver on a 3.0 Tesla (T) system. All sequences were performed with b values of 50 and 800 s/mm(2) and identical parameters except for signal averages (two for navigator-triggered, one for breathhold, and four for free-breathing) and repetition time (3389 ms for navigator-triggered, 1500 ms for breathhold, and 4400 ms for free-breathing). A total of 74 lesions (50 malignant, 24 benign) were evaluated. The signal-to-noise ratios (SNR) of the liver and lesions, contrast-to-noise ratios (CNR) of each lesion, and ADC values of the liver and lesions were compared for each DWI sequence. The detection sensitivity and characterization accuracy were also compared.
RESULTS: The SNRs of the liver and lesions were significantly lower for breathhold DWI than for non-breathhold DWI (navigator-triggered and free-breathing DWI) for all b values. The CNRs of the lesions were also significantly lower for breathhold DWI than for non-breathhold DWI. The ADC values of the liver and focal lesions measured using the three DWI techniques were not significantly different and showed good correlation. For lesion detection and characterization, there were no significant differences between breathhold and non-breathhold DWI.
CONCLUSION: Both breathhold and non-breathhold DWI are comparable for the detection or characterization of focal liver lesions at 3.0T; however, non-breathhold DWI provides higher SNR and CNR than breathhold DWI. In addition, although free-breathing and navigator-triggered DWI sequences show similar performance for 3.0T liver imaging, free-breathing DWI is more time efficient than navigator-triggered DWI.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  3.0T; MRI; diffusion-weighted imaging (DWI); free-breathing; liver

Mesh:

Year:  2012        PMID: 23188562     DOI: 10.1002/jmri.23949

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  20 in total

1.  3.0 Tesla magnetic resonance imaging: A new standard in liver imaging?

Authors:  Rossano Girometti
Journal:  World J Hepatol       Date:  2015-07-28

2.  Performance of U-net based pyramidal lucas-kanade registration on free-breathing multi-b-value diffusion MRI of the kidney.

Authors:  Jun Lv; Wenjian Huang; Jue Zhang; Xiaoying Wang
Journal:  Br J Radiol       Date:  2018-03-28       Impact factor: 3.039

3.  Prediction of histological grade of hepatocellular carcinoma using quantitative diffusion-weighted MRI: a retrospective multivendor study.

Authors:  Yusuke Ogihara; Yoshio Kitazume; Yoshihiro Iwasa; Shinichi Taura; Yoshiro Himeno; Tomo Kimura; Seishi Sawano; Shigehiko Terada; Minoru Tanabe; Yukihisa Saida; Ukihide Tateishi
Journal:  Br J Radiol       Date:  2018-02-05       Impact factor: 3.039

4.  Hepatic ADC map as an adjunct to conventional abdominal MRI to evaluate hepatic fibrotic and clinical cirrhotic severity in biliary atresia patients.

Authors:  Steven Shinn-Forng Peng; Yung-Ming Jeng; Wen-Ming Hsu; Justin Cheng-Ta Yang; Ming-Chih Ho
Journal:  Eur Radiol       Date:  2015-04-29       Impact factor: 5.315

5.  Cardiorespiratory motion-tracking via self-refocused rosette navigators.

Authors:  David Rigie; Thomas Vahle; Tiejun Zhao; Björn Czekella; Lynn J Frohwein; Klaus Schäfers; Fernando E Boada
Journal:  Magn Reson Med       Date:  2019-01-07       Impact factor: 4.668

Review 6.  Advances in diffusion-weighted imaging.

Authors:  Lorenzo Mannelli; Stephanie Nougaret; Hebert A Vargas; Richard K G Do
Journal:  Radiol Clin North Am       Date:  2015-05       Impact factor: 2.303

7.  Quantitative liver ADC measurements using diffusion-weighted MRI at 3 Tesla: evaluation of reproducibility and perfusion dependence using different techniques for respiratory compensation.

Authors:  Nis Elbrønd Larsen; Søren Haack; Lars Peter Skovgaard Larsen; Erik Morre Pedersen
Journal:  MAGMA       Date:  2013-03-13       Impact factor: 2.310

Review 8.  Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.

Authors:  Irene Polycarpou; Georgios Soultanidis; Charalampos Tsoumpas
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2021-07-05       Impact factor: 4.226

9.  Renal Diffusion-Weighted Imaging in Healthy Dogs: Reproducibility, Test-Retest Repeatability, and Selection of the Optimal b-value Combination.

Authors:  Sang-Kwon Lee; Juryeoung Lee; Seolyn Jang; Eunji Lee; Chang-Yeop Jeon; Kyung-Seoub Lim; Yeung Bae Jin; Jihye Choi
Journal:  Front Vet Sci       Date:  2021-07-02

10.  Diagnostic accuracy of apparent diffusion coefficient (ADC) value in differentiating malignant from benign solid liver lesions: a systematic review and meta-analysis.

Authors:  Farhad Nalaini; Fatemeh Shahbazi; Seyedeh Maryam Mousavinezhad; Ali Ansari; Mohammadgharib Salehi
Journal:  Br J Radiol       Date:  2021-06-16       Impact factor: 3.629

View more