Generation rate of carbon monoxide from CO2 arc welding.

Jun Ojima1.   

Abstract

OBJECTIVES: CO poisoning has been a serious industrial hazard in Japanese workplaces. Although incomplete combustion is the major cause of CO generation, there is a risk of CO poisoning during some welding operations. The aim of the present study was to evaluate the generation rate of CO from CO2 arc welding under controlled laboratory conditions and estimate the ventilation requirements for the prevention of CO poisoning.
METHODS: Bead on plate welding was carried out with an automatic welding robot on a rolled steel base metal under several conditions. The concentration of emitted CO from the welding was measured by a real-time CO monitor in a well-ventilated laboratory that was free from ambient CO contamination. The generation rate of CO was obtained from the three measurements-the flow rate of the welding exhaust gas, CO concentration in the exhaust gas and the arcing time. Then the ventilation requirement to prevent CO poisoning was calculated.
RESULTS: The generation rate of CO was found to be 386-883 ml/min with a solid wire and 331-1,293 ml/min with a flux cored wire respectively. It was found that the CO concentration in a room would be maintained theoretically below the OSHA PEL (50 ppm) providing the ventilation rate in the room was 6.6-25.9 m3/min. The actual ventilation requirement was then estimated to be 6.6-259 m3/min considering incomplete mixing.
CONCLUSIONS: In order to prevent CO poisoning, some countermeasures against gaseous emission as well as welding fumes should be taken eagerly.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23183022     DOI: 10.1539/joh.12-0180-br

Source DB:  PubMed          Journal:  J Occup Health        ISSN: 1341-9145            Impact factor:   2.708


  3 in total

1.  Generation rate and particle size distribution of wood dust by handheld sanding operation.

Authors:  Jun Ojima
Journal:  J Occup Health       Date:  2016-09-30       Impact factor: 2.708

2.  Prevention against carbon monoxide poisoning emanating from burning coal briquettes - Generation rate of carbon monoxide and ventilation requirement.

Authors:  Jun Ojima
Journal:  Ind Health       Date:  2021-10-27       Impact factor: 2.707

3.  Carbon monoxide poisoning-induced encephalopathy in a carbon dioxide arc welder: a case report.

Authors:  Seongwon Ma; Hoekyeong Seo; Dong Joon Park; Byeongju Choi; Shinhee Ye
Journal:  Ann Occup Environ Med       Date:  2022-08-03
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.