Literature DB >> 23181468

Micropatterned surfaces functionalized with electroactive peptides for detecting protease release from cells.

Dong-Sik Shin1, Ying Liu, Yandong Gao, Timothy Kwa, Zimple Matharu, Alexander Revzin.   

Abstract

Matrix metalloproteinases (MMPs) regulate composition of the extracellular matrix and play a critical role in cancer, fibrosis, and wound healing. This article describes a novel peptide-based electrochemical biosensor for detecting activity of cell-secreted protease MMP9. In this sensing strategy, a peptide specific to MMP9 was modified with a redox label (methylene blue (MB)) and immobilized on microfabricated 300 μm diameter Au electrodes. Challenging the electrodes with known concentrations of MMP9 resulted in the cleavage of the MB containing peptide fragment and caused a decrease in electrical signal measured by square wave voltammetry (SWV). The limit of detection for MMP9 was determined to be 60 pM with a linear range extending to 50 nM. In preparation to detect cell-secreted MMP9, glass surfaces with Au electrode arrays were further micropatterned with poly(ethylene glycol) (PEG) gel to define annular cell adhesive regions next to electrodes and render the remainder of the surface nonfouling. The surfaces were further modified with CD14 antibody to promote attachment of monocytes. The peptide-modified electrode arrays were integrated into PDMS microfluidic devices and incubated with U-937 cells, transformed monocytes known to produce MMPs. These studies revealed a 3-fold higher electrochemical signal from ∼400 activated monocytes after 10 min activation compared to nonactivated monocytes. Whereas this article focuses on MMP9 detection, the general strategy of employing redox-labeled peptides on electrodes should be broadly applicable for detection of other proteases and should have clinical as well as basic science applications.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23181468      PMCID: PMC3677045          DOI: 10.1021/ac302547p

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  38 in total

1.  Quantitative methods for spatially resolved adsorption/desorption measurements in real time by surface plasmon resonance microscopy.

Authors:  Jennifer S Shumaker-Parry; Charles T Campbell
Journal:  Anal Chem       Date:  2004-02-15       Impact factor: 6.986

2.  Electrochemical assay of protease activities based on polycation/polyanion complex as substrate and polyion sensitive membrane electrode detection.

Authors:  Hisham S M Abd-Rabboh; Stacey A Nevins; Nedime Dürüst; Mark E Meyerhoff
Journal:  Biosens Bioelectron       Date:  2003-03       Impact factor: 10.618

3.  Overview of matrix metalloproteinase expression in cultured human cells.

Authors:  T A Giambernardi; G M Grant; G P Taylor; R J Hay; V M Maher; J J McCormick; R J Klebe
Journal:  Matrix Biol       Date:  1998-03       Impact factor: 11.583

Review 4.  Matrix metalloproteinases and tumor metastasis.

Authors:  Elena I Deryugina; James P Quigley
Journal:  Cancer Metastasis Rev       Date:  2006-03       Impact factor: 9.264

5.  Aptamer-based electrochemical biosensor for interferon gamma detection.

Authors:  Ying Liu; Nazgul Tuleouva; Erlan Ramanculov; Alexander Revzin
Journal:  Anal Chem       Date:  2010-10-01       Impact factor: 6.986

6.  The expression and activation of matrix metalloproteinase-2 in rat brain after implantation of C6 rat glioma cells.

Authors:  T Kodera; T Nakagawa; T Kubota; M Kabuto; K Sato; H Kobayashi
Journal:  J Neurooncol       Date:  2000       Impact factor: 4.130

7.  Anti-invasive effect of MMI-166, a new selective matrix metalloproteinase inhibitor, in cervical carcinoma cell lines.

Authors:  Masahiro Iwasaki; Akira Nishikawa; Takashi Fujimoto; Noriyuki Akutagawa; Kengo Manase; Toshiaki Endo; Koichi Yoshida; Ryuji Maekawa; Takayuki Yoshioka; Ryuichi Kudo
Journal:  Gynecol Oncol       Date:  2002-04       Impact factor: 5.482

Review 8.  Matrix metalloproteinase-9 and autoimmune diseases.

Authors:  Maya Ram; Yaniv Sherer; Yehuda Shoenfeld
Journal:  J Clin Immunol       Date:  2006-05-02       Impact factor: 8.317

9.  Expression and localization of 92 kDa type IV collagenase/gelatinase B (MMP-9) in human gliomas.

Authors:  J S Rao; M Yamamoto; S Mohaman; Z L Gokaslan; G N Fuller; W G Stetler-Stevenson; V H Rao; L A Liotta; G L Nicolson; R E Sawaya
Journal:  Clin Exp Metastasis       Date:  1996-01       Impact factor: 5.150

10.  A novel coumarin-labelled peptide for sensitive continuous assays of the matrix metalloproteinases.

Authors:  C G Knight; F Willenbrock; G Murphy
Journal:  FEBS Lett       Date:  1992-01-27       Impact factor: 4.124

View more
  6 in total

1.  Micropatterned sensing hydrogels integrated with reconfigurable microfluidics for detecting protease release from cells.

Authors:  Kyung Jin Son; Dong-Sik Shin; Timothy Kwa; Yandong Gao; Alexander Revzin
Journal:  Anal Chem       Date:  2013-11-26       Impact factor: 6.986

2.  A General, Label-Free and Homogeneous Electrochemical Strategy for Probing of Protease Activity and Screening of Inhibitor.

Authors:  Yunxiao Feng; Gang Liu; Fan Zhang; Jianwen Liu; Ming La; Ning Xia
Journal:  Micromachines (Basel)       Date:  2022-05-21       Impact factor: 3.523

3.  Two-dimensional sum-frequency generation reveals structure and dynamics of a surface-bound peptide.

Authors:  Jennifer E Laaser; David R Skoff; Jia-Jung Ho; Yongho Joo; Arnaldo L Serrano; Jay D Steinkruger; Padma Gopalan; Samuel H Gellman; Martin T Zanni
Journal:  J Am Chem Soc       Date:  2014-01-08       Impact factor: 15.419

Review 4.  Electrochemical Biosensors as Potential Diagnostic Devices for Autoimmune Diseases.

Authors:  Anca Florea; Gheorghe Melinte; Ioan Simon; Cecilia Cristea
Journal:  Biosensors (Basel)       Date:  2019-03-04

5.  Electrochemical Impedance-Based Biosensors for the Label-Free Detection of the Nucleocapsid Protein from SARS-CoV-2.

Authors:  Hana Cho; Suhyun Shim; Won Woo Cho; Sungbo Cho; Hanseung Baek; Sang-Myung Lee; Dong-Sik Shin
Journal:  ACS Sens       Date:  2022-06-02       Impact factor: 9.618

Review 6.  Bioanalytical methods for circulating extracellular matrix-related proteins: new opportunities in cancer diagnosis.

Authors:  Ramón Lorenzo-Gómez; Rebeca Miranda-Castro; Noemí de-Los-Santos-Álvarez; María Jesús Lobo-Castañón
Journal:  Anal Bioanal Chem       Date:  2021-06-05       Impact factor: 4.142

  6 in total