Literature DB >> 23176607

Assessment of sleep-disordered breathing using a non-contact bio-motion sensor.

Alberto Zaffaroni1, Brian Kent, Emer O'Hare, Conor Heneghan, Patricia Boyle, Geraldine O'Connell, Michael Pallin, Philip de Chazal, Walter T McNicholas.   

Abstract

Obstructive sleep apnoea is a highly prevalent but under-diagnosed disorder. The gold standard for diagnosis of obstructive sleep apnoea is inpatient polysomnography. This is resource intensive and inconvenient for the patient, and the development of ambulatory diagnostic modalities has been identified as a key research priority. SleepMinder (BiancaMed, NovaUCD, Ireland) is a novel, non-contact, bedside sensor, which uses radio-waves to measure respiration and movement. Previous studies have shown it to be effective in measuring sleep and respiration. We sought to assess its utility in the diagnosis of obstructive sleep apnoea. SleepMinder and polysomnographic assessment of sleep-disordered breathing were performed simultaneously on consecutive subjects recruited prospectively from our sleep clinic. We assessed the diagnostic accuracy of SleepMinder in identifying obstructive sleep apnoea, and how SleepMinder assessment of the apnoea-hypopnoea index correlated with polysomnography. Seventy-four subjects were recruited. The apnoea-hypopnoea index as measured by SleepMinder correlated strongly with polysomnographic measurement (r = 0.90; P ≤ 0.0001). When a diagnostic threshold of moderate-severe (apnoea-hypopnoea index ≥15 events h(-1) ) obstructive sleep apnoea was used, SleepMinder displayed a sensitivity of 90%, a specificity of 92% and an accuracy of 91% in the diagnosis of sleep-disordered breathing. The area under the curve for the receiver operator characteristic was 0.97. SleepMinder correctly classified obstructive sleep apnoea severity in the majority of cases, with only one case different from equivalent polysomnography by more than one diagnostic class. We conclude that in an unselected clinical population undergoing investigation for suspected obstructive sleep apnoea, SleepMinder measurement of sleep-disordered breathing correlates significantly with polysomnography.
© 2012 European Sleep Research Society.

Entities:  

Mesh:

Year:  2012        PMID: 23176607     DOI: 10.1111/j.1365-2869.2012.01056.x

Source DB:  PubMed          Journal:  J Sleep Res        ISSN: 0962-1105            Impact factor:   3.981


  14 in total

Review 1.  Pediatric Home Sleep Apnea Testing: Slowly Getting There!

Authors:  Hui-Leng Tan; Leila Kheirandish-Gozal; David Gozal
Journal:  Chest       Date:  2015-12       Impact factor: 9.410

2.  Diagnostic accuracy of level IV portable sleep monitors versus polysomnography for obstructive sleep apnea: a systematic review and meta-analysis.

Authors:  Lusine Abrahamyan; Yeva Sahakyan; Suzanne Chung; Petros Pechlivanoglou; Joanna Bielecki; Steven M Carcone; Valeria E Rac; Michael Fitzpatrick; Murray Krahn
Journal:  Sleep Breath       Date:  2018-01-09       Impact factor: 2.816

3.  Validation of a non-contact screening device for the combination of sleep-disordered breathing and periodic limb movements in sleep.

Authors:  Gerhard Weinreich; Sarah Terjung; Yi Wang; Stefanie Werther; Alberto Zaffaroni; Helmut Teschler
Journal:  Sleep Breath       Date:  2017-08-18       Impact factor: 2.816

Review 4.  Sleep-disordered Breathing in Heart Failure.

Authors:  Simon G Pearse; Martin R Cowie; Rakesh Sharma; Ali Vazir
Journal:  Eur Cardiol       Date:  2015-12

5.  Digital Health and Sleep-Disordered Breathing: A Systematic Review and Meta-Analysis.

Authors:  Talita Rosa; Kersti Bellardi; Alonço Viana; Yifei Ma; Robson Capasso
Journal:  J Clin Sleep Med       Date:  2018-09-15       Impact factor: 4.062

6.  Toward standardizing the clinical testing protocols of point-of-care devices for obstructive sleep apnea diagnosis.

Authors:  Vivek Tangudu; Kahkashan Afrin; Sandy Reddy; Nicolaas E P Deutz; Steven Woltering; Satish T S Bukkapatnam
Journal:  Sleep Breath       Date:  2020-08-31       Impact factor: 2.816

7.  Contact-free screening for obstructive sleep apnea: comfort, especially in a physically distanced brave new world.

Authors:  Bahman Chavoshan; George Dungan; Peter Y Liu
Journal:  J Clin Sleep Med       Date:  2021-05-01       Impact factor: 4.062

8.  Screening for obstructive sleep apnea using a contact-free system compared with polysomnography.

Authors:  Rui Zhao; JianBo Xue; Xiao Song Dong; Hui Zhi; JiaNan Chen; Long Zhao; XueLi Zhang; Jing Li; Thomas Penzel; Fang Han
Journal:  J Clin Sleep Med       Date:  2021-05-01       Impact factor: 4.062

9.  Assessment of human respiration patterns via noncontact sensing using Doppler multi-radar system.

Authors:  Changzhan Gu; Changzhi Li
Journal:  Sensors (Basel)       Date:  2015-03-16       Impact factor: 3.576

10.  Development and validation of a novel non-contact monitor of nocturnal respiration for identifying sleep-disordered breathing in patients with heart failure.

Authors:  Henry Oluwasefunmi Savage; Rami N Khushaba; Alberto Zaffaroni; Michael Colefax; Steven Farrugia; Klaus Schindhelm; Helmut Teschler; Gerhard Weinreich; Hartmut Grueger; Martina Neddermann; Conor Heneghan; Anita Simonds; Martin R Cowie
Journal:  ESC Heart Fail       Date:  2016-03-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.