Literature DB >> 23171509

A compact frequency-domain photon migration system for integration into commercial hybrid small animal imaging scanners for fluorescence tomography.

Chinmay D Darne1, Yujie Lu, I-Chih Tan, Banghe Zhu, John C Rasmussen, Anne M Smith, Shikui Yan, Eva M Sevick-Muraca.   

Abstract

The work presented herein describes the system design and performance evaluation of a miniaturized near-infrared fluorescence (NIRF) frequency-domain photon migration (FDPM) system with non-contact excitation and homodyne detection capability for small animal fluorescence tomography. The FDPM system was developed specifically for incorporation into a Siemens micro positron emission tomography/computed tomography (microPET/CT) commercial scanner for hybrid small animal imaging, but could be adapted to other systems. Operating at 100 MHz, the system noise was minimized and the associated amplitude and phase errors were characterized to be ±0.7% and ±0.3°, respectively. To demonstrate the tomographic ability, a commercial mouse-shaped phantom with 50 µM IRDye800CW and ⁶⁸Ga containing inclusion was used to associate PET and NIRF tomography. Three-dimensional mesh generation and anatomical referencing was accomplished through CT. A third-order simplified spherical harmonics approximation (SP₃) algorithm, for efficient prediction of light propagation in small animals, was tailored to incorporate the FDPM approach. Finally, the PET-NIRF target co-localization accuracy was analyzed in vivo with a dual-labeled imaging agent targeting orthotopic growth of human prostate cancer. The obtained results validate the integration of time-dependent fluorescence tomography system within a commercial microPET/CT scanner for multimodality small animal imaging.

Entities:  

Mesh:

Year:  2012        PMID: 23171509      PMCID: PMC3533362          DOI: 10.1088/0031-9155/57/24/8135

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  36 in total

1.  Improvement of fluorescence-enhanced optical tomography with improved optical filtering and accurate model-based reconstruction algorithms.

Authors:  Yujie Lu; Banghe Zhu; Chinmay Darne; I-Chih Tan; John C Rasmussen; Eva M Sevick-Muraca
Journal:  J Biomed Opt       Date:  2011-12       Impact factor: 3.170

2.  A time domain fluorescence tomography system for small animal imaging.

Authors:  Anand T N Kumar; Scott B Raymond; Andrew K Dunn; Brian J Bacskai; David A Boas
Journal:  IEEE Trans Med Imaging       Date:  2008-08       Impact factor: 10.048

3.  A gantry-based tri-modality system for bioluminescence tomography.

Authors:  Han Yan; Yuting Lin; William C Barber; Mehmet Burcin Unlu; Gultekin Gulsen
Journal:  Rev Sci Instrum       Date:  2012-04       Impact factor: 1.523

4.  Simultaneous PET and multispectral 3-dimensional fluorescence optical tomography imaging system.

Authors:  Changqing Li; Yongfeng Yang; Gregory S Mitchell; Simon R Cherry
Journal:  J Nucl Med       Date:  2011-08       Impact factor: 10.057

5.  Hybrid system for simultaneous fluorescence and x-ray computed tomography.

Authors:  Ralf B Schulz; Angelique Ale; Athanasios Sarantopoulos; Marcus Freyer; Eric Soehngen; Marta Zientkowska; Vasilis Ntziachristos
Journal:  IEEE Trans Med Imaging       Date:  2009-11-10       Impact factor: 10.048

6.  Imaging prostate cancer lymph node metastases with a multimodality contrast agent.

Authors:  Mary A Hall; Sunkuk Kwon; Holly Robinson; Pier-Anne Lachance; Ali Azhdarinia; Ranjani Ranganathan; Roger E Price; Wenyaw Chan; Eva M Sevick-Muraca
Journal:  Prostate       Date:  2011-05-02       Impact factor: 4.104

7.  Pharmacokinetics of ICG and HPPH-car for the detection of normal and tumor tissue using fluorescence, near-infrared reflectance imaging: a case study.

Authors:  M Gurfinkel; A B Thompson; W Ralston; T L Troy; A L Moore; T A Moore; J D Gust; D Tatman; J S Reynolds; B Muggenburg; K Nikula; R Pandey; R H Mayer; D J Hawrysz; E M Sevick-Muraca
Journal:  Photochem Photobiol       Date:  2000-07       Impact factor: 3.421

8.  A microcomputed tomography guided fluorescence tomography system for small animal molecular imaging.

Authors:  Dax Kepshire; Niculae Mincu; Michael Hutchins; Josiah Gruber; Hamid Dehghani; Justin Hypnarowski; Frederic Leblond; Mario Khayat; Brian W Pogue
Journal:  Rev Sci Instrum       Date:  2009-04       Impact factor: 1.523

9.  Dual-labeled trastuzumab-based imaging agent for the detection of human epidermal growth factor receptor 2 overexpression in breast cancer.

Authors:  Lakshmi Sampath; Sunkuk Kwon; Shi Ke; Wei Wang; Rachel Schiff; Michel E Mawad; Eva M Sevick-Muraca
Journal:  J Nucl Med       Date:  2007-09       Impact factor: 10.057

10.  Noninvasive quantitative imaging of lymph function in mice.

Authors:  Sunkuk Kwon; Eva M Sevick-Muraca
Journal:  Lymphat Res Biol       Date:  2007       Impact factor: 2.589

View more
  7 in total

1.  Far-red fluorescence gene reporter tomography for determination of placement and viability of cell-based gene therapies.

Authors:  Yujie Lu; Chinmay D Darne; I-Chih Tan; Banghe Zhu; Mary A Hall; Zawaunyka W Lazard; Alan R Davis; Lashan Simpson; Eva M Sevick-Muraca; Elizabeth A Olmsted-Davis
Journal:  Opt Express       Date:  2013-10-07       Impact factor: 3.894

2.  A matter of collection and detection for intraoperative and noninvasive near-infrared fluorescence molecular imaging: to see or not to see?

Authors:  Banghe Zhu; John C Rasmussen; Eva M Sevick-Muraca
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

3.  Non-invasive fluorescence imaging under ambient light conditions using a modulated ICCD and laser diode.

Authors:  Banghe Zhu; John C Rasmussen; Eva M Sevick-Muraca
Journal:  Biomed Opt Express       Date:  2014-01-24       Impact factor: 3.732

4.  In vivo imaging of orthotopic prostate cancer with far-red gene reporter fluorescence tomography and in vivo and ex vivo validation.

Authors:  Yujie Lu; Chinmay D Darne; I-Chih Tan; Grace Wu; Nathaniel Wilganowski; Holly Robinson; Ali Azhdarinia; Banghe Zhu; John C Rasmussen; Eva M Sevick-Muraca
Journal:  J Biomed Opt       Date:  2013-10       Impact factor: 3.170

5.  Differentiation of tumor vasculature heterogeneity levels in small animals based on total hemoglobin concentration using magnetic resonance-guided diffuse optical tomography in vivo.

Authors:  Tiffany C Kwong; Mitchell Hsing; Yuting Lin; David Thayer; Mehmet Burcin Unlu; Min-Ying Su; Gultekin Gulsen
Journal:  Appl Opt       Date:  2016-07-20       Impact factor: 1.980

6.  Enhanced fluorescence diffuse optical tomography with indocyanine green-encapsulating liposomes targeted to receptors for vascular endothelial growth factor in tumor vasculature.

Authors:  Saeid Zanganeh; Yan Xu; Carl V Hamby; Marina V Backer; Joseph M Backer; Quing Zhu
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

Review 7.  Real-time fluorescence image-guided oncologic surgery.

Authors:  Suman B Mondal; Shengkui Gao; Nan Zhu; Rongguang Liang; Viktor Gruev; Samuel Achilefu
Journal:  Adv Cancer Res       Date:  2014       Impact factor: 6.242

  7 in total