Literature DB >> 23169797

Kidney transplant: functional assessment with diffusion-tensor MR imaging at 3T.

Rotem S Lanzman1, Alexandra Ljimani, Gael Pentang, Panagiota Zgoura, Hakan Zenginli, Patric Kröpil, Philipp Heusch, Julia Schek, Falk R Miese, Dirk Blondin, Gerald Antoch, Hans-Jörg Wittsack.   

Abstract

PURPOSE: To evaluate the feasibility of diffusion-tensor (DT) imaging at 3 T for functional assessment of transplanted kidneys.
MATERIALS AND METHODS: This study was approved by the local ethics committee; written informed consent was obtained. Between August 2009 and October 2010, 40 renal transplant recipients were prospectively included in this study and examined with a clinical 3-T magnetic resonance (MR) imager. An echo-planar DT imaging sequence was performed in coronal orientation by using five b values (0, 200, 400, 600, 800 sec/mm(2)) and 20 diffusion directions. The fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were determined for the cortex and medulla of the transplanted kidney. Relationships between FA, ADC, and allograft function, determined by the estimated glomerular filtration rate (eGFR), were assessed by using Pearson correlation coefficient. ADC and FA were compared between patients with good or moderate allograft function (group A; eGFR > 30 mL/min/1.73 m(2)) and patients with impaired function (group B; eGFR ≤ 30 mL/min/1.73 m(2)) by using a student t test. P < .05 indicated a statistically significant difference.
RESULTS: Mean FA of the renal medulla and cortex was significantly higher in group A (0.39 ± 0.06 and 0.17 ± 0.4) compared with group B (0.27 ± 0.05 and 0.14 ± 0.03) (P < .001 and P = .009, respectively). Mean ADCs of renal cortex and medulla were significantly higher in group A than in group B (P = .007 and P = .01, respectively). In group B, mean medullary FA was significantly lower in patients whose renal function did not recover (0.22 ± 0.02) compared with those with stable allograft function at 6 months (0.29 ± 0.05, P < .001). There was significant correlation between eGFR and medullary FA (r = 0.65, P < .001), cortical ADC (r = 0.43, P = .003), and medullary ADC (r = 0.35, P = .01).
CONCLUSION: DT imaging is a promising noninvasive technique for functional assessment of renal allografts. FA values in the renal medulla exhibit a good correlation with renal function. RSNA, 2012

Entities:  

Mesh:

Year:  2012        PMID: 23169797     DOI: 10.1148/radiol.12112522

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  45 in total

Review 1.  [Functional magnetic resonance imaging of the kidneys].

Authors:  R S Lanzman; M Notohamiprodjo; H J Wittsack
Journal:  Radiologe       Date:  2015-12       Impact factor: 0.635

Review 2.  Nanosized contrast agents to noninvasively detect kidney inflammation by magnetic resonance imaging.

Authors:  Joshua M Thurman; Natalie J Serkova
Journal:  Adv Chronic Kidney Dis       Date:  2013-11       Impact factor: 3.620

3.  Assessment of renal allograft function early after transplantation with isotropic resolution diffusion tensor imaging.

Authors:  Wen-jun Fan; Tao Ren; Qiong Li; Pan-li Zuo; Miao-miao Long; Chun-bai Mo; Li-hua Chen; Li-xiang Huang; Wen Shen
Journal:  Eur Radiol       Date:  2015-05-28       Impact factor: 5.315

Review 4.  Current MRI techniques for the assessment of renal disease.

Authors:  Takamune Takahashi; Feng Wang; Christopher C Quarles
Journal:  Curr Opin Nephrol Hypertens       Date:  2015-05       Impact factor: 2.894

5.  Fast diffusion kurtosis imaging of fibrotic mouse kidneys.

Authors:  B F Kjølby; A R Khan; A Chuhutin; L Pedersen; J B Jensen; S Jakobsen; D Zeidler; R Sangill; J R Nyengaard; S N Jespersen; B Hansen
Journal:  NMR Biomed       Date:  2016-10-12       Impact factor: 4.044

Review 6.  Functional assessment of transplanted kidneys with magnetic resonance imaging.

Authors:  Yu-Ting Wang; Ying-Chun Li; Long-Lin Yin; Hong Pu; Jia-Yuan Chen
Journal:  World J Radiol       Date:  2015-10-28

Review 7.  Imaging-based diagnosis of acute renal allograft rejection.

Authors:  Gerold Thölking; Katharina Schuette-Nuetgen; Dominik Kentrup; Helga Pawelski; Stefan Reuter
Journal:  World J Transplant       Date:  2016-03-24

Review 8.  MRI tools for assessment of microstructure and nephron function of the kidney.

Authors:  Luke Xie; Kevin M Bennett; Chunlei Liu; G Allan Johnson; Jeff Lei Zhang; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2016-09-14

9.  Diffusion-weighted imaging in the assessment of renal function in patients with diabetes mellitus type 2.

Authors:  Tijana Mrđanin; Olivera Nikolić; Una Molnar; Milena Mitrović; Viktor Till
Journal:  MAGMA       Date:  2020-07-30       Impact factor: 2.310

10.  T1-mapping for assessment of ischemia-induced acute kidney injury and prediction of chronic kidney disease in mice.

Authors:  Katja Hueper; Matti Peperhove; Song Rong; Jessica Gerstenberg; Michael Mengel; Martin Meier; Marcel Gutberlet; Susanne Tewes; Amelie Barrmeyer; Rongjun Chen; Herman Haller; Frank Wacker; Dagmar Hartung; Faikah Gueler
Journal:  Eur Radiol       Date:  2014-07-05       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.