Literature DB >> 2316693

Brachial artery diameter changes associated with cardiopulmonary baroreflex activation in humans.

G M London1, B M Pannier, S Laurent, P Lacolley, M E Safar.   

Abstract

Stimulation of receptors in the cardiopulmonary compartment produces a vasodilatation of forearm resistive vessels. A possible participation of large conduit arteries in such adjustments, studied in situ, has not been clearly documented in humans. We used a dual-crystal pulsed Doppler system to determine whether leg elevation in recumbent subjects is associated with changes in brachial artery diameter (BAD) and blood velocity (BV) in humans. BA diameter, velocity, and flow, together with arterial pressure and heart rate, were measured in 20 normal subjects in supine position and after passive leg raising. BAD increased immediately after leg elevation from 4.03 +/- 0.11 to 4.56 +/- 0.13 mm (P less than 0.001) parallel with an increase in BV from 6.05 +/- 1.18 to 7.1 +/- 1.36 cm/s (P less than 0.02). A positive correlation between BAD enlargement and BV increase was observed during the initial peak response (P less than 0.01). Subsequent measures indicated that BAD remained enlarged throughout the whole period of leg raising, whereas BV returned to the base-line values. Brachial artery volumic flow augmented during the initial phase of leg raising from 46 +/- 8 to 74 +/- 15.5 ml/min (P less than 0.01) and remained elevated throughout the whole period of leg elevation. This study shows that arteries participate in hemodynamic adjustments induced by positional changes associated with cardiopulmonary baroreflex activation.

Entities:  

Mesh:

Year:  1990        PMID: 2316693     DOI: 10.1152/ajpheart.1990.258.3.H773

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  5 in total

Review 1.  Toward microendoscopy-inspired cardiac optogenetics in vivo: technical overview and perspective.

Authors:  Aleksandra Klimas; Emilia Entcheva
Journal:  J Biomed Opt       Date:  2014-08       Impact factor: 3.170

2.  Central venous pressure measurements improve the accuracy of leg raising-induced change in pulse pressure to predict fluid responsiveness.

Authors:  Karim Lakhal; Stephan Ehrmann; Isabelle Runge; Dalila Benzekri-Lefèvre; Annick Legras; Pierre François Dequin; Emmanuelle Mercier; Michel Wolff; Bernard Régnier; Thierry Boulain
Journal:  Intensive Care Med       Date:  2010-01-29       Impact factor: 17.440

Review 3.  The Relationship between Vascular Function and the Autonomic Nervous System.

Authors:  Eisuke Amiya; Masafumi Watanabe; Issei Komuro
Journal:  Ann Vasc Dis       Date:  2014-05-16

4.  Change in left ventricular velocity time integral during Trendelenburg maneuver predicts fluid responsiveness in cardiac surgical patients in the operating room.

Authors:  Guo-Guang Ma; Li-Ying Xu; Jing-Chao Luo; Jun-Yi Hou; Guang-Wei Hao; Ying Su; Kai Liu; Shen-Ji Yu; Guo-Wei Tu; Zhe Luo
Journal:  Quant Imaging Med Surg       Date:  2021-07

5.  Common carotid artery diameter responds to intravenous volume expansion: an ultrasound observation.

Authors:  Tobias Hilbert; Sven Klaschik; Richard K Ellerkmann; Christian Putensen; Marcus Thudium
Journal:  Springerplus       Date:  2016-06-23
  5 in total