INTRODUCTION: The aim of this study was to assess the normal values for Smith-Madigan inotropy (SMI), Smith-Madigan inotropy index (SMII), oxygen delivery (DO2) and oxygen delivery index DO2I in healthy term neonates on the first day of life and during circulatory adaptation over the first three days of life.
METHODS: Hemodynamics of the left heart were measured non-invasively in 71 normal full-term neonates over the first three days using the Ultrasonic Cardiac Output Monitor (USCOM). This was combined with hemoglobin concentration from umbilical cord blood and pulse oximetry to calculate DO2 and DO2I. Blood pressure was measured using automated oscillometry and combined with the hemodynamic measures and hemoglobin concentration using the Smith-Madigan method to calculate inotropy (SMI) and inotropy index (SMII).
RESULTS: SMI and SMII showed no significant change during the study period, ranging from 154 to 168 mW and 694 to 731 mW/m(2). Mean (SD) DO2 and DO2I showed a significant fall over three days from 131 (63) ml/min and 596 (278) ml/m(2)/min to 118 (46) ml/min and 517 (173) ml/m(2)/min (p<0.01 and <0.001 respectively) with a corresponding decrease in cardiac output from 758 (143) ml/min to 658 (131) ml/min, (p=0.002). There was no significant change in stroke volume, heart rate, SMI or SMII within the first day. DO2 and DO2I showed small but significant decreases within the first day from 153 (46) ml/min and 699 (174) ml/min/m(2) to 129 (36) ml/min and 609 (141) ml/min/m(2) (p=0.017 and 0.048 respectively).
CONCLUSIONS: Normal inotropy of the left heart and systemic DO2 values in healthy full-term neonates over the first three days of life were assessed using the USCOM. Subjects showed stable myocardial contractility over the first three days with decreasing DO2 and DO2I in line with the decrease in cardiac output (CO). DO2 and DO2I showed small but significant reductions during the first 24 h. USCOM proved to be a feasible and convenient non-invasive bedside tool to assess inotropy and oxygen delivery in neonates.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23164929     DOI: 10.1016/j.earlhumdev.2012.10.006

Source DB:  PubMed          Journal:  Early Hum Dev        ISSN: 0378-3782            Impact factor:   2.079


  8 in total

1.  USCOM-window to the circulation: utility of supra-sternal Doppler in an elderly anaesthetized patient for a robotic cystectomy.

Authors:  Lester A H Critchley; Li Huang
Journal:  J Clin Monit Comput       Date:  2013-08-02       Impact factor: 2.502

2.  Measurement of Cardiac Output Using an Ultrasonic Cardiac Output Monitor (USCOM) in Patients with Single-Ventricle Physiology.

Authors:  Wonshill Koh; Kristin A Schneider; Huaiyu Zang; Sarosh P Batlivala; Matthew P Monteleone; Alexis L Benscoter; Meghan M Chlebowski; Ilias D Iliopoulos; David S Cooper
Journal:  Pediatr Cardiol       Date:  2022-02-06       Impact factor: 1.838

Review 3.  Understanding the Haemodynamics of Hypertension.

Authors:  B E Smith; V M Madigan
Journal:  Curr Hypertens Rep       Date:  2018-04-10       Impact factor: 5.369

4.  [Application of ultrasonic cardiac output monitor in evaluation of cardiac function in children with severe pneumonia].

Authors:  Juan Fan; Zhi-Ying Chen; Peng-Yuan Chen; Chang-Hui Chen
Journal:  Zhongguo Dang Dai Er Ke Za Zhi       Date:  2016-09

5.  Urgent ultrasound guided hemodynamic assessments by a pediatric medical emergency team: a pilot study.

Authors:  David J Zorko; Karen Choong; Jonathan Gilleland; Barbara Agar; Shawn Baker; Cindy Brennan; Eleanor Pullenayegum
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

6.  Reduced Echocardiographic Inotropy Index after Cardiopulmonary Bypass Is Associated With Complications After Cardiac Surgery: An Institutional Outcomes Study.

Authors:  Michael R Mathis; Neal M Duggal; Allison M Janda; Jordan L Fennema; Bo Yang; Francis D Pagani; Michael D Maile; Ryan E Hofer; Elizabeth S Jewell; Milo C Engoren
Journal:  J Cardiothorac Vasc Anesth       Date:  2021-01-27       Impact factor: 2.894

7.  Oxygen Delivery and Oxygen Consumption in Pediatric Fluid Refractory Septic Shock During the First 42 h of Therapy and Their Relationship to 28-Day Outcome.

Authors:  Chulananda D A Goonasekera; Joseph A Carcillo; Akash Deep
Journal:  Front Pediatr       Date:  2018-10-23       Impact factor: 3.418

8.  Age-specific non-invasive transcutaneous Doppler ultrasound derived haemodynamic reference ranges in elderly Chinese adults.

Authors:  Cangel Pui-Yee Chan; Nandini Agarwal; King-Keung Sin; Sangeeta Narain; Brendan E Smith; Colin A Graham; Timothy H Rainer
Journal:  BBA Clin       Date:  2014-09-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.