| Literature DB >> 23164609 |
J R Price1, X Didelot, D W Crook, M J Llewelyn, J Paul.
Abstract
BACKGROUND: Staphylococcus aureus remains a leading cause of hospital-acquired infection but weaknesses inherent in currently available typing methods impede effective infection prevention and control. The high resolution offered by whole genome sequencing has the potential to revolutionise our understanding and management of S. aureus infection. AIM: To outline the practicalities of whole genome sequencing and discuss how it might shape future infection control practice.Entities:
Mesh:
Year: 2012 PMID: 23164609 PMCID: PMC7132511 DOI: 10.1016/j.jhin.2012.10.003
Source DB: PubMed Journal: J Hosp Infect ISSN: 0195-6701 Impact factor: 3.926
Comparison of the Staphylococcus aureus typing techniques
| Technique | Set-up cost | Cost per isolate | Current availability | Time to results | Data analysis | Data transferability | Common nomenclature | Level of resolution |
|---|---|---|---|---|---|---|---|---|
| PFGE | Low | £4–7 | Local and reference laboratories | 2–3 days | Minimal | Limited | USA type (USA-) | Lineage |
| MLVA | Low | £3–5 | Research and reference laboratories | 24 h | Minimal | Limited | MLVA complex (Sa-) | Lineage |
| MLST | High | £20 | Research and reference laboratories | Days | Moderate | Yes – widely | Sequence type (ST-) | Lineage |
| spa | High | £3–5 | Local and reference laboratories | 24 h | Moderate | Yes – widely | Spa-type (t-) | Lineage |
| WGS | High | ∼£100 | Research laboratories | Real time | High | Being addressed | To be determined | Base pair |
PFGE, pulsed-field gel electrophoresis; MLVA, multi-locus variable-number tandem-repeat analysis; MLST, multi-locus sequence typing; spa, spa-typing; WGS, whole genome sequencing.
Third generation sequencing platforms.
Comparison of sequencing technologies
| Sequencing technology platform | |||
|---|---|---|---|
| First generation | Second generation | Third generation | |
| Resolution | Average of multiple DNA copies | Average of multiple DNA copies | Single molecule |
| Read length generated | 800–1000 bp | <400 bp | 1000–10,000 bp |
| Financial cost per base | High | Low | Moderate |
| Financial cost per run | Low | High | Low |
| Sample preparation | Moderate | Complex | Variable |
| Time to result | Hours | Days | Minutes to hours |