Literature DB >> 23160912

Topographical analysis of the femoral components of ex vivo total knee replacements.

Susan C Scholes1, Emma Kennard, Rajkumar Gangadharan, David Weir, Jim Holland, David Deehan, Thomas J Joyce.   

Abstract

With greater numbers of primary knee replacements now performed in younger patients there is a demand for improved performance. Surface roughness of the femoral component has been proposed as a causative mechanism for premature prosthesis failure. Nineteen retrieved total knee replacements were analysed using a non-contacting profilometer to measure the femoral component surface roughness. The Hood technique was used to analyse the wear and surface damage of the matching ultra-high molecular weight polyethylene (UHMWPE) tibial components. All femoral components were shown to be up to 11× rougher after their time in vivo while 95 % showed a change in skewness, further indicating wear. This increase in roughness occurred relatively soon after implantation (within 1 year) and remained unchanged thereafter. Mostly, this roughness was more apparent on the lateral condyle than the medial. This increased femoral surface roughness likely led to damage of the UHMWPE tibial component and increased Hood scores.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23160912     DOI: 10.1007/s10856-012-4815-z

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  15 in total

1.  Role of abrasion of the femoral component in revision knee arthroplasty.

Authors:  M S Siddique; M C Rao; D J Deehan; I M Pinder
Journal:  J Bone Joint Surg Br       Date:  2003-04

2.  Influence of microscopic surface asperities on the wear of ultra-high molecular weight polyethylene in a knee prosthesis.

Authors:  C-H Cho; T Murakami; Y Sawae
Journal:  Proc Inst Mech Eng H       Date:  2010       Impact factor: 1.617

3.  The increasing financial burden of knee revision surgery in the United States.

Authors:  Carlos Lavernia; David J Lee; Victor Hugo Hernandez
Journal:  Clin Orthop Relat Res       Date:  2006-05       Impact factor: 4.176

4.  The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene.

Authors:  J Fisher; P Firkins; E A Reeves; J L Hailey; G H Isaac
Journal:  Proc Inst Mech Eng H       Date:  1995       Impact factor: 1.617

5.  Prevalence of primary and revision total hip and knee arthroplasty in the United States from 1990 through 2002.

Authors:  Steven Kurtz; Fionna Mowat; Kevin Ong; Nathan Chan; Edmund Lau; Michael Halpern
Journal:  J Bone Joint Surg Am       Date:  2005-07       Impact factor: 5.284

6.  Posterior condyle surface damage on retrieved femoral knee components.

Authors:  Colin D C Burnell; Jan-M Brandt; Martin J Petrak; Robert B Bourne
Journal:  J Arthroplasty       Date:  2011-05-13       Impact factor: 4.757

7.  Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses.

Authors:  R W Hood; T M Wright; A H Burstein
Journal:  J Biomed Mater Res       Date:  1983-09

8.  The dramatic increase in total knee replacement utilization rates in the United States cannot be fully explained by growth in population size and the obesity epidemic.

Authors:  Elena Losina; Thomas S Thornhill; Benjamin N Rome; John Wright; Jeffrey N Katz
Journal:  J Bone Joint Surg Am       Date:  2012-02-01       Impact factor: 5.284

9.  Why are total knee replacements revised?: analysis of early revision in a community knee implant registry.

Authors:  Terence J Gioe; Kathleen K Killeen; Katherine Grimm; Susan Mehle; Karen Scheltema
Journal:  Clin Orthop Relat Res       Date:  2004-11       Impact factor: 4.176

10.  The significance of surface changes on retrieved femoral components after total knee replacement.

Authors:  A Lakdawala; S Todo; G Scott
Journal:  J Bone Joint Surg Br       Date:  2005-06
View more
  6 in total

1.  Changes in surface topography at the TKA backside articulation following in vivo service: a retrieval analysis.

Authors:  Richard J Holleyman; Susan C Scholes; David Weir; Simon S Jameson; Jim Holland; Tom J Joyce; David J Deehan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-07       Impact factor: 4.342

2.  Evaluating the Surface Topography of Pyrolytic Carbon Finger Prostheses through Measurement of Various Roughness Parameters.

Authors:  Andrew Naylor; Sumedh C Talwalkar; Ian A Trail; Thomas J Joyce
Journal:  J Funct Biomater       Date:  2016-04-14

3.  In Response to Michael Wininger's Commentary: Common Roadblocks for Biomaterials Metrologists.

Authors:  Andrew Naylor
Journal:  J Funct Biomater       Date:  2016-07-27

4.  Peripheral snap-fit locking mechanisms and smooth surface finish of tibial trays reduce backside wear in fixed-bearing total knee arthroplasty.

Authors:  Łukasz Łapaj; Adrian Mróz; Paweł Kokoszka; Jacek Markuszewski; Justyna Wendland; Celina Helak-Łapaj; Jacek Kruczyński
Journal:  Acta Orthop       Date:  2016-10-26       Impact factor: 3.717

5.  High wear resistance of femoral components coated with titanium nitride: a retrieval analysis.

Authors:  Christian Fabry; Carmen Zietz; Axel Baumann; Reinhard Ehall; Rainer Bader
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-05-20       Impact factor: 4.342

6.  Comparative retrieval analysis of antioxidant polyethylene: bonding of vitamin-E does not reduce in-vivo surface damage.

Authors:  Dominic T Mathis; Joshua Schmidli; Michael T Hirschmann; Felix Amsler; Johann Henckel; Harry Hothi; Alister Hart
Journal:  BMC Musculoskelet Disord       Date:  2021-11-30       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.