Literature DB >> 23160036

Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis.

Jingyin Liu1, Shaoxia Pan, Jing Dong, Zhongjun Mo, Yubo Fan, Hailan Feng.   

Abstract

OBJECTIVE: The aim of this study was to evaluate strain distribution in peri-implant bone, stress in the abutments and denture stability of mandibular overdentures anchored by different numbers of implants under different loading conditions, through three-dimensional finite element analysis (3D FEA).
METHODS: Four 3D finite element models of mandibular overdentures were established, using between one and four Straumann implants with Locator attachments. Three types of load were applied to the overdenture in each model: 100N vertical and inclined loads on the left first molar and a 100N vertical load on the lower incisors. The biomechanical behaviours of peri-implant bone, implants, abutments and overdentures were recorded.
RESULTS: Under vertical load on the lower incisors, the single-implant overdenture rotated over the implant from side to side, and no obvious increase of strain was found in peri-implant bone. Under the same loading conditions, the two-implant-retained overdenture showed more apparent rotation around the fulcrum line passing through the two implants, and the maximum equivalent stress in the abutments was higher than in the other models. In the three-implant-supported overdenture, no strain concentration was found in cortical bone around the middle implant under three loading conditions. CONCLUSIONS AND CLINICAL SIGNIFICANCE: Single-implant-retained mandibular overdentures do not show damaging strain concentration in the bone around the only implant and may be a cost-effective treatment option for edentulous patients. A third implant can be placed between the original two when patients rehabilitated by two-implant overdentures report constant and obvious denture rotation around the fulcrum line.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23160036     DOI: 10.1016/j.jdent.2012.11.008

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  22 in total

1.  Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis.

Authors:  Pinar Ercal; Aysegul Erten Taysi; Demet Cagil Ayvalioglu; Meltem Mert Eren; Soner Sismanoglu
Journal:  Med Biol Eng Comput       Date:  2021-03-17       Impact factor: 2.602

2.  Comparison of marginal bone loss and patient satisfaction in single and double-implant assisted mandibular overdenture by immediate loading.

Authors:  Sara Tavakolizadeh; Fariborz Vafaee; Masume Khoshhal; Zahra Ebrahimzadeh
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

3.  A clinical study on the 6-year outcomes of immediately loaded three implants for completely edentulous mandibles: "the all-on-3 concept".

Authors:  Mustafa Ayna; Keyvan Sagheb; Ralf Gutwald; Henning Wieker; Christian Flörke; Yahya Açil; Jörg Wiltfang; Aydin Gülses
Journal:  Odontology       Date:  2019-07-05       Impact factor: 2.634

4.  Stress-strain distribution at bone-implant interface of two splinted overdenture systems using 3D finite element analysis.

Authors:  Mostafa Omran Hussein
Journal:  J Adv Prosthodont       Date:  2013-08-31       Impact factor: 1.904

Review 5.  Biomechanical factors related to occlusal load transfer in removable complete dentures.

Authors:  Jarosław Żmudzki; Grzegorz Chladek; Jacek Kasperski
Journal:  Biomech Model Mechanobiol       Date:  2014-12-20

6.  Effect of cantilever length on stress distribution around implants in mandibular overdentures supported by two and three implants.

Authors:  Behnaz Ebadian; Ramin Mosharraf; Niloufar Khodaeian
Journal:  Eur J Dent       Date:  2016 Jul-Sep

7.  Stress distribution patterns of implant supported overdentures-analog versus finite element analysis: A comparative in-vitro study.

Authors:  Soumyadev Satpathy; C L Satish Babu; Shilpa Shetty; Bharat Raj
Journal:  J Indian Prosthodont Soc       Date:  2015 Jul-Sep

8.  Performance of attachments used in implant-supported overdentures: review of trends in the literature.

Authors:  Damian J Lee
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

Review 9.  Biomechanics of oral mucosa.

Authors:  Junning Chen; Rohana Ahmad; Wei Li; Michael Swain; Qing Li
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

10.  Single implant supported mandibular overdenture: A literature review.

Authors:  Sudhindra Mahoorkar; Srinidhi Bhat; Radhika Kant
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.