OBJECTIVE: To compare the ergonomics and workload of the surgeon during single-site suturing while using the magnetic anchoring and guidance system (MAGS) camera vs a conventional laparoscope.
METHODS: Seven urologic surgeons were enrolled and divided into an expert group (n=2) and a novice group (n=5) according to their laparoendoscopic single-site (LESS) experience. Each surgeon performed 2 conventional LESS and 2 MAGS camera-assisted LESS vesicostomy closures in a porcine model. A Likert scale (scoring 1-5) questionnaire assessing workload, ergonomics, technical difficulty, visualization, and needle handling, as well as a validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire were used to evaluate the tasks and workloads.
RESULTS: MAGS LESS suturing was universally favored by expert and novice surgeons compared with conventional LESS in workload (3.4 vs 4.2), ergonomics (3.4 vs 4.4), technical challenge (3.3 vs 4.3), visualization (2.4 vs 3.3), and needle handling (3.1 vs 3.9 respectively; P<.05 for all categories). Surgeon NASA-TLX assessments found MAGS LESS suturing significantly decreased the workload in physical demand (P=.004), temporal demand (P=.017), and effort (P=.006). External instrument clashing was significantly reduced in MAGS LESS suturing (P<.001). The total operative time of MAGS LESS suturing was comparable to that of conventional LESS (P=.89).
CONCLUSION: MAGS camera technology significantly decreased surgeon workload and improved ergonomics. Nevertheless, LESS suturing and knot tying remains a challenging task that requires training, regardless of which camera is used.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 23153954     DOI: 10.1016/j.urology.2012.09.018

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  8 in total

1.  Objective analysis of surgeons' ergonomy during laparoendoscopic single-site surgery through the use of surface electromyography and a motion capture data glove.

Authors:  F J Pérez-Duarte; M Lucas-Hernández; A Matos-Azevedo; J A Sánchez-Margallo; I Díaz-Güemes; F M Sánchez-Margallo
Journal:  Surg Endosc       Date:  2013-12-13       Impact factor: 4.584

Review 2.  Laparoendoscopic single-site surgery in kidney surgery: clinical experience and future perspectives.

Authors:  Panagiotis Kallidonis; Stavros Kontogiannis; Iason Kyriazis; Ioannis Georgiopoulos; Abdulrahman Al-Aown; Jens-Uwe Stolzenburg; Evangelos Liatsikos
Journal:  Curr Urol Rep       Date:  2013-10       Impact factor: 3.092

3.  A magnetic levitation robotic camera for minimally invasive surgery: Useful for NOTES?

Authors:  Nicola Di Lorenzo; Livia Cenci; Massimiliano Simi; Claudio Arcudi; Valeria Tognoni; Achille Lucio Gaspari; Pietro Valdastri
Journal:  Surg Endosc       Date:  2016-09-22       Impact factor: 4.584

Review 4.  Magnetic anchoring guidance system in video-assisted thoracic surgery.

Authors:  Agnese Giaccone; Piergiorgio Solli; Luca Bertolaccini
Journal:  J Vis Surg       Date:  2017-02-13

Review 5.  Innovative surgical endoscopes in video-assisted thoracic surgery.

Authors:  Truman Cheng; Calvin S H Ng; Zheng Li
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

6.  Advantages associated with the use of a wound retractor compared to a rigid trocar inserted via the camera port during video-assisted thoracic surgery.

Authors:  Mitsuhiro Kamiyoshihara; Hitoshi Igai; Ryohei Yoshikawa; Fumi Ohsawa; Tomohiro Yazawa
Journal:  J Thorac Dis       Date:  2019-03       Impact factor: 2.895

7.  Development of an arm support system to improve ergonomics in laparoscopic surgery: study design and provisional results.

Authors:  Benjamin Steinhilber; Sascha Hoffmann; Kristian Karlovic; Stefan Pfeffer; Thomas Maier; Omar Hallasheh; Stephan Kruck; Robert Seibt; Monika A Rieger; Michael Heidingsfeld; Ronny Feuer; Oliver Sawodny; Ralf Rothmund; Karl-Dietrich Sievert
Journal:  Surg Endosc       Date:  2014-12-25       Impact factor: 4.584

8.  Laparoendoscopic single-site simple nephrectomy using a magnetic anchoring system in a porcine model.

Authors:  Young Hyo Choi; Hye Won Lee; Seo Yeon Lee; Deok Hyun Han; Seong Il Seo; Seong Soo Jeon; Hyun Moo Lee; Han Yong Choi; Byong Chang Jeong
Journal:  Investig Clin Urol       Date:  2016-05-03
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.