Literature DB >> 23146399

Liquid chromatographic determination of microcystins in water samples following pre-column excimer fluorescence derivatization with 4-(1-pyrene)butanoic acid hydrazide.

Tadashi Hayama1, Kenji Katoh, Takayoshi Aoki, Miki Itoyama, Kenichiro Todoroki, Hideyuki Yoshida, Masatoshi Yamaguchi, Hitoshi Nohta.   

Abstract

A method to measure the concentrations of microcystins (MCs) in water samples has been developed by incorporating pre-column fluorescence derivatization and liquid chromatography (LC). A solid-phase extraction for pretreatment was used to extract the MCs in water samples. The MCs were derivatized with excimer-forming 4-(1-pyrene)butanoic acid hydrazide (PBH). The MCs could then be detected by fluorescence after separation with a pentafluorophenyl (PFP)-modified superficially porous (core shell) particle LC column. The derivatization reactions of MCs with PBH proceeded easily in the presence of 4,6-dimethoxy-1,3,5-triazin-2-yl-4-methylmorpholinium (DMT-MM) as a condensation reagent, and the resulting derivatives could be easily separated on the PFP column. The derivatives were selectively detected at excimer fluorescence wavelengths (440-540 nm). The instrument detection limit and the instrument quantification limit of the MCs standards were 0.4-1.2 μg L(-1) and 1.4-3.9 μg L(-1), respectively. The method was validated at 0.1 and 1.0 μg L(-1) levels in tap and pond water samples, and the recovery of MCs was between 67 and 101% with a relative standard deviation of 11%. The proposed method can be used to quantify trace amounts of MCs in water samples.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23146399     DOI: 10.1016/j.aca.2012.10.009

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Chemical cross-linking/mass spectrometry targeting acidic residues in proteins and protein complexes.

Authors:  Alexander Leitner; Lukasz A Joachimiak; Pia Unverdorben; Thomas Walzthoeni; Judith Frydman; Friedrich Förster; Ruedi Aebersold
Journal:  Proc Natl Acad Sci U S A       Date:  2014-06-17       Impact factor: 11.205

2.  Electrochemical Aptatoxisensor Responses on Nanocomposites Containing Electro-Deposited Silver Nanoparticles on Poly(Propyleneimine) Dendrimer for the Detection of Microcystin-LR in Freshwater.

Authors:  Mawethu P Bilibana; Avril R Williams; Candice Rassie; Christopher E Sunday; Hlamulo Makelane; Lindsay Wilson; Nomaphelo Ntshongontshi; Abongile N Jijana; Milua Masikini; Priscilla G L Baker; Emmanuel I Iwuoha
Journal:  Sensors (Basel)       Date:  2016-11-11       Impact factor: 3.576

Review 3.  Core-Shell Columns in High-Performance Liquid Chromatography: Food Analysis Applications.

Authors:  Raffaella Preti
Journal:  Int J Anal Chem       Date:  2016-04-10       Impact factor: 1.885

  3 in total