Literature DB >> 23146367

Removed antibiotic-impregnated cement spacers in two-stage revision joint arthroplasty do not show biofilm formation in vivo.

Justin W Griffin1, Stacey J Guillot, Jan A Redick, James A Browne.   

Abstract

Use of antibiotic-impregnated spacers is common in the two-stage approach to treatment of periprosthetic joint infection despite the lack of information regarding in vivo performance of these implants. Antibiotic elution levels likely often fall below the minimal inhibitory concentration need to inhibit bacterial growth, raising concern that the spacers themselves may provide a potential attachment site for biofilm formation. Advanced microscopy was used in this study to evaluate the surface characteristics of antibiotic-eluting spacers collected at the time of prosthesis reimplantation from 6 patients undergoing two-stage treatment for an infected total joint arthroplasty. Scanning electron microscopy and confocal scanning microscopy of the removed spacers revealed modest fibrous matrix formation and inflammatory cells with no biofilm or bacteria detected. This study supports the continued use of antibiotic spacers in the treatment of periprosthetic joint infection.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23146367     DOI: 10.1016/j.arth.2012.06.019

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

1.  Unsatisfactory outcome of arthrodesis performed after septic failure of revision total knee arthroplasty.

Authors:  Eric Röhner; Christoph Windisch; Katy Nuetzmann; Max Rau; Michael Arnhold; Georg Matziolis
Journal:  J Bone Joint Surg Am       Date:  2015-02-18       Impact factor: 5.284

Review 2.  Emperor's new clothes: Is particle disease really infected particle disease?

Authors:  Marcin K Wasko; Stuart B Goodman
Journal:  J Orthop Res       Date:  2016-05-30       Impact factor: 3.494

3.  Bacterial biofilm formation is variably inhibited by different formulations of antibiotic-loaded bone cement in vitro.

Authors:  Giovanni Balato; Emanuela Roscetto; Adriana Vollaro; Olimpio Galasso; Giorgio Gasparini; Tiziana Ascione; Maria Rosaria Catania; Massimo Mariconda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2018-10-28       Impact factor: 4.342

Review 4.  Calcium phosphate scaffolds combined with bone morphogenetic proteins or mesenchymal stem cells in bone tissue engineering.

Authors:  Han Sun; Hui-Lin Yang
Journal:  Chin Med J (Engl)       Date:  2015-04-20       Impact factor: 2.628

Review 5.  Antibiotic Elution from Hip and Knee Acrylic Bone Cement Spacers: A Systematic Review.

Authors:  Konstantinos Anagnostakos; Christof Meyer
Journal:  Biomed Res Int       Date:  2017-06-05       Impact factor: 3.411

6.  Low sensitivity of implant sonication when screening for infection in revision surgery.

Authors:  Floor M Van Diek; Christiaan G M Albers; Miranda L Van Hooff; Jacques F Meis; Jon H M Goosen
Journal:  Acta Orthop       Date:  2017-03-13       Impact factor: 3.717

Review 7.  Antibiotic-Loaded Polymethylmethacrylate Beads and Spacers in Treatment of Orthopedic Infections and the Role of Biofilm Formation.

Authors:  Tom A G van Vugt; Jacobus J Arts; Jan A P Geurts
Journal:  Front Microbiol       Date:  2019-07-25       Impact factor: 5.640

8.  Mapping Bacterial Biofilm on Features of Orthopedic Implants In Vitro.

Authors:  Kelly Moore; Niraj Gupta; Tripti Thapa Gupta; Khushi Patel; Jacob R Brooks; Anne Sullivan; Alan S Litsky; Paul Stoodley
Journal:  Microorganisms       Date:  2022-03-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.