Literature DB >> 23140958

A potentiometric chiral sensor for L-Phenylalanine based on crosslinked polymethylacrylic acid-polycarbazole hybrid molecularly imprinted polymer.

Yu Chen1, Lei Chen, Ruilin Bi, Lan Xu, Yan Liu.   

Abstract

A novel chiral molecularly imprinted polymer (MIP) sensor for L-Phenylalanine has been developed, which is constructed by electrochemically driven cross-linking a pendant polymer precursor, poly[2-(N-carbazolyl)ethyl methacrylate-co-meth-acrylic acid]s (PCEMMAs). In this MIP sensing material, the recognition sites, the insulating polymethylacrylic acid (PMAA), were covalently bonded to the conducting polycarbazole which could be used as signal transfer interface between recognition layer and electrode. The mole ratio of copolymerizing monomers, 2-(N-carbazolyl) ethyl methacrylate:methylacrylic acid (CE:MAA), and the scanning cycles of electropolymerization were adjusted during the preparation of MIP sensing material. The optimized conditions, CE:MAA=3:2 and 20 scanning cycles, were obtained. And then the properties of MIP films were characterized by atomic force microscope (AFM), X-ray photoelectron spectroscopy (XPS) and water contact angle. Open circuit potential-time technique was used to estimate the enantioselectivity of the MIP sensor. The results indicate that the promising sensor preferentially responses L-Phenylalanine (L-Phe) over D-Phenylalanine (D-Phe) with a selectivity coefficient K(D)(L)=5.75×10(-4) and the limit of detection (LOD) is 1.37μM, which reveals its good enantioselectivity and sensitivity. Crown
Copyright © 2012. Published by Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23140958     DOI: 10.1016/j.aca.2012.09.048

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  5 in total

1.  A New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer.

Authors:  Zahra Bangaleh; Hayedeh Bagheri Sadeghi; Soltan Ahmad Ebrahimi; Parvaneh Najafizadeh
Journal:  Iran J Pharm Res       Date:  2019       Impact factor: 1.696

Review 2.  Recent Advances in Electrosynthesized Molecularly Imprinted Polymer Sensing Platforms for Bioanalyte Detection.

Authors:  Robert D Crapnell; Alexander Hudson; Christopher W Foster; Kasper Eersels; Bart van Grinsven; Thomas J Cleij; Craig E Banks; Marloes Peeters
Journal:  Sensors (Basel)       Date:  2019-03-09       Impact factor: 3.576

Review 3.  A Review on Electrochemical Sensors and Biosensors Used in Phenylalanine Electroanalysis.

Authors:  Ancuta Dinu; Constantin Apetrei
Journal:  Sensors (Basel)       Date:  2020-04-28       Impact factor: 3.576

Review 4.  Key Enabling Technologies for Point-of-Care Diagnostics.

Authors:  Elisabetta Primiceri; Maria Serena Chiriacò; Francesca M Notarangelo; Antonio Crocamo; Diego Ardissino; Marco Cereda; Alessandro P Bramanti; Marco A Bianchessi; Gianluigi Giannelli; Giuseppe Maruccio
Journal:  Sensors (Basel)       Date:  2018-10-24       Impact factor: 3.576

5.  An Enantioselective Potentiometric Sensor for 2-Amino-1-Butanol Based on Chiral Porous Organic Cage CC3-R.

Authors:  Bang-Jin Wang; Ai-Hong Duan; Jun-Hui Zhang; Sheng-Ming Xie; Qiu-E Cao; Li-Ming Yuan
Journal:  Molecules       Date:  2019-01-24       Impact factor: 4.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.