Literature DB >> 23128074

Effects of image contrast on functional MRI image registration.

Javier Gonzalez-Castillo1, Kristen N Duthie, Ziad S Saad, Carlton Chu, Peter A Bandettini, Wen-Ming Luh.   

Abstract

Lack of tissue contrast and existing inhomogeneous bias fields from multi-channel coils have the potential to degrade the output of registration algorithms; and consequently degrade group analysis and any attempt to accurately localize brain function. Non-invasive ways to improve tissue contrast in fMRI images include the use of low flip angles (FAs) well below the Ernst angle and longer repetition times (TR). Techniques to correct intensity inhomogeneity are also available in most mainstream fMRI data analysis packages; but are not used as part of the pre-processing pipeline in many studies. In this work, we use a combination of real data and simulations to show that simple-to-implement acquisition/pre-processing techniques can significantly improve the outcome of both functional-to-functional and anatomical-to-functional image registrations. We also emphasize the need of tissue contrast on EPI images to be able to appropriately evaluate the quality of the alignment. In particular, we show that the use of low FAs (e.g., θ≤40°), when physiological noise considerations permit such an approach, significantly improves accuracy, consistency and stability of registration for data acquired at relatively short TRs (TR≤2s). Moreover, we also show that the application of bias correction techniques significantly improves alignment both for array-coil data (known to contain high intensity inhomogeneity) as well as birdcage-coil data. Finally, improvements in alignment derived from the use of the first infinite-TR volumes (ITVs) as targets for registration are also demonstrated. For the purpose of quantitatively evaluating the different scenarios, two novel metrics were developed: Mean Voxel Distance (MVD) to evaluate registration consistency, and Deviation of Mean Voxel Distance (dMVD) to evaluate registration stability across successive alignment attempts. Published by Elsevier Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23128074      PMCID: PMC3545034          DOI: 10.1016/j.neuroimage.2012.10.076

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  31 in total

1.  Occurrence of adverse reactions to gadolinium-based contrast material and management of patients at increased risk: a survey of the American Society of Neuroradiology Fellowship Directors.

Authors:  K P Murphy; K T Szopinski; R H Cohan; B Mermillod; J H Ellis
Journal:  Acad Radiol       Date:  1999-11       Impact factor: 3.173

2.  Motion correction algorithms may create spurious brain activations in the absence of subject motion.

Authors:  L Freire; J F Mangin
Journal:  Neuroimage       Date:  2001-09       Impact factor: 6.556

3.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

4.  Image registration based on boundary mapping.

Authors:  C Davatzikos; J L Prince; R N Bryan
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

5.  Multi-modal volume registration by maximization of mutual information.

Authors:  W M Wells; P Viola; H Atsumi; S Nakajima; R Kikinis
Journal:  Med Image Anal       Date:  1996-03       Impact factor: 8.545

6.  Registration of [18F]FDG microPET and small-animal MRI.

Authors:  Douglas J Rowland; Joel R Garbow; Richard Laforest; Abraham Z Snyder
Journal:  Nucl Med Biol       Date:  2005-08       Impact factor: 2.408

7.  Long-term retention of gadolinium in tissues from nephrogenic systemic fibrosis patient after multiple gadolinium-enhanced MRI scans: case report and implications.

Authors:  Charu Thakral; Jihad Alhariri; Jerrold L Abraham
Journal:  Contrast Media Mol Imaging       Date:  2007-07       Impact factor: 3.161

8.  Accurate and robust brain image alignment using boundary-based registration.

Authors:  Douglas N Greve; Bruce Fischl
Journal:  Neuroimage       Date:  2009-06-30       Impact factor: 6.556

9.  Frequency and severity of acute allergic-like reactions to gadolinium-containing i.v. contrast media in children and adults.

Authors:  Jonathan R Dillman; James H Ellis; Richard H Cohan; Peter J Strouse; Sophia C Jan
Journal:  AJR Am J Roentgenol       Date:  2007-12       Impact factor: 3.959

10.  Reperfused myocardial infarctions on T1- and susceptibility-enhanced MRI: evidence for loss of compartmentalization of contrast media.

Authors:  M Saeed; M F Wendland; T Masui; C B Higgins
Journal:  Magn Reson Med       Date:  1994-01       Impact factor: 4.668

View more
  10 in total

1.  Tracking ongoing cognition in individuals using brief, whole-brain functional connectivity patterns.

Authors:  Javier Gonzalez-Castillo; Colin W Hoy; Daniel A Handwerker; Meghan E Robinson; Laura C Buchanan; Ziad S Saad; Peter A Bandettini
Journal:  Proc Natl Acad Sci U S A       Date:  2015-06-29       Impact factor: 11.205

2.  Imaging the spontaneous flow of thought: Distinct periods of cognition contribute to dynamic functional connectivity during rest.

Authors:  Javier Gonzalez-Castillo; César Caballero-Gaudes; Natasha Topolski; Daniel A Handwerker; Francisco Pereira; Peter A Bandettini
Journal:  Neuroimage       Date:  2019-08-25       Impact factor: 6.556

3.  Using fMRI to decode true thoughts independent of intention to conceal.

Authors:  Zhi Yang; Zirui Huang; Javier Gonzalez-Castillo; Rui Dai; Georg Northoff; Peter Bandettini
Journal:  Neuroimage       Date:  2014-05-17       Impact factor: 6.556

4.  Evaluation of multi-echo ICA denoising for task based fMRI studies: Block designs, rapid event-related designs, and cardiac-gated fMRI.

Authors:  Javier Gonzalez-Castillo; Puja Panwar; Laura C Buchanan; Cesar Caballero-Gaudes; Daniel A Handwerker; David C Jangraw; Valentinos Zachariou; Souheil Inati; Vinai Roopchansingh; John A Derbyshire; Peter A Bandettini
Journal:  Neuroimage       Date:  2016-07-27       Impact factor: 6.556

5.  Incorporating relaxivities to more accurately reconstruct MR images.

Authors:  Muge Karaman; Iain P Bruce; Daniel B Rowe
Journal:  Magn Reson Imaging       Date:  2015-01-15       Impact factor: 2.546

6.  Comparison of arterial spin labeling registration strategies in the multi-center GENetic frontotemporal dementia initiative (GENFI).

Authors:  Henri J M M Mutsaerts; Jan Petr; David L Thomas; Enrico De Vita; David M Cash; Matthias J P van Osch; Xavier Golay; Paul F C Groot; Sebastien Ourselin; John van Swieten; Robert Laforce; Fabrizio Tagliavini; Barbara Borroni; Daniela Galimberti; James B Rowe; Caroline Graff; Francesca B Pizzini; Elizabeth Finger; Sandro Sorbi; Miguel Castelo Branco; Jonathan D Rohrer; Mario Masellis; Bradley J MacIntosh
Journal:  J Magn Reson Imaging       Date:  2017-05-08       Impact factor: 4.813

7.  Towards HCP-Style macaque connectomes: 24-Channel 3T multi-array coil, MRI sequences and preprocessing.

Authors:  Joonas A Autio; Matthew F Glasser; Takayuki Ose; Chad J Donahue; Matteo Bastiani; Masahiro Ohno; Yoshihiko Kawabata; Yuta Urushibata; Katsutoshi Murata; Kantaro Nishigori; Masataka Yamaguchi; Yuki Hori; Atsushi Yoshida; Yasuhiro Go; Timothy S Coalson; Saad Jbabdi; Stamatios N Sotiropoulos; Henry Kennedy; Stephen Smith; David C Van Essen; Takuya Hayashi
Journal:  Neuroimage       Date:  2020-04-08       Impact factor: 6.556

8.  Synthesizing pseudo-T2w images to recapture missing data in neonatal neuroimaging with applications in rs-fMRI.

Authors:  Sydney Kaplan; Anders Perrone; Dimitrios Alexopoulos; Jeanette K Kenley; Deanna M Barch; Claudia Buss; Jed T Elison; Alice M Graham; Jeffrey J Neil; Thomas G O'Connor; Jerod M Rasmussen; Monica D Rosenberg; Cynthia E Rogers; Aristeidis Sotiras; Damien A Fair; Christopher D Smyser
Journal:  Neuroimage       Date:  2022-03-11       Impact factor: 7.400

9.  The quest for the best: The impact of different EPI sequences on the sensitivity of random effect fMRI group analyses.

Authors:  Evgeniya Kirilina; Antoine Lutti; Benedikt A Poser; Felix Blankenburg; Nikolaus Weiskopf
Journal:  Neuroimage       Date:  2015-11-11       Impact factor: 6.556

10.  Beware (Surprisingly Common) Left-Right Flips in Your MRI Data: An Efficient and Robust Method to Check MRI Dataset Consistency Using AFNI.

Authors:  Daniel R Glen; Paul A Taylor; Bradley R Buchsbaum; Robert W Cox; Richard C Reynolds
Journal:  Front Neuroinform       Date:  2020-05-25       Impact factor: 4.081

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.