Effect of the embolization material in the dose calculation for stereotactic radiosurgery of arteriovenous malformations.

Olga Olinca Galván de la Cruz1, José Manuel Lárraga-Gutiérrez, Sergio Moreno-Jiménez, Olivia Amanda García-Garduño, Miguel Angel Celis.   

Abstract

It is reported in the literature that the material used in an embolization of an arteriovenous malformation (AVM) can attenuate the radiation beams used in stereotactic radiosurgery (SRS) up to 10% to 15%. The purpose of this work is to assess the dosimetric impact of this attenuating material in the SRS treatment of embolized AVMs, using Monte Carlo simulations assuming clinical conditions. A commercial Monte Carlo dose calculation engine was used to recalculate the dose distribution of 20 AVMs previously planned with a pencil beam dose calculation algorithm. Dose distributions were compared using the following metrics: average, minimal and maximum dose of AVM, and 2D gamma index. The effect in the obliteration rate was investigated using radiobiological models. It was found that the dosimetric impact of the embolization material is less than 1.0 Gy in the prescription dose to the AVM for the 20 cases studied. The impact in the obliteration rate is less than 4.0%. There is reported evidence in the literature that embolized AVMs treated with SRS have low obliteration rates. This work shows that there are dosimetric implications that should be considered in the final treatment decisions for embolized AVMs.
Copyright © 2013 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23127781     DOI: 10.1016/j.meddos.2012.07.009

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  2 in total

1.  Authors' reply to "Dosimetric of intracranial stereotactic radiosurgery: only 'an exercise of style'".

Authors:  Harald Treuer; Moritz Hoevels; Klaus Luyken; Veerle Visser-Vandewalle; Jochen Wirths; Martin Kocher; Maximilian Ruge
Journal:  Strahlenther Onkol       Date:  2015-10       Impact factor: 3.621

2.  Dosimetric effects of embolization material artefacts in arteriovenous malformations stereotactic radiosurgery on treatment planning calculation.

Authors:  Abousaleh Elawadi; Mukhtar Alshanqity; Hussain AlHussain; Reham Mohamed; Yasser Orz; Sultan Alqahtani; Sayel Melheim
Journal:  Phys Imaging Radiat Oncol       Date:  2022-07-02