Literature DB >> 23127056

Dosimetric investigation of accelerated partial breast irradiation (APBI) using CyberKnife.

Qianyi Xu1, Yan Chen, Jimm Grimm, Jiajin Fan, Lili An, Jinyu Xue, Niraj Pahlajani, Tamara Lacouture.   

Abstract

PURPOSE: To investigate the dosimetric feasibility of accelerated partial breast irradiation (APBI) using CyberKnife.
METHODS: Fourteen previously treated patients with early-stage breast cancer were selected for a retrospective study. Six of these patients had been treated to 38.5 Gy in 10 fractions in a phase III accelerated partial breast trial and the rest of the patients were treated to 50.4 Gy in 28 fractions. In this planning study, the guidelines in the protocol for the phase III partial breast trial were followed for organ delineation and CyberKnife planning. The achievable dosimetric parameters from all CyberKnife plans were compared to Intensity-modulated radiation therapy (IMRT) and 3D-CRT methods. The reproducibility of the dose delivery with and without respiratory motion was assessed through delivering a patient plan to a breast phantom. Different dose calculation algorithms were also compared between ray tracing and Monte Carlo.
RESULTS: For all the patients in the study, the dosimetric parameters met the guidelines from the NSABP B39∕RTOG 0413 protocol strictly. The mean PTV volume covered by 100% of the prescription dose was 95.7 ± 0.7% (94.7%-97.1%). The mean maximal dose was 104 ± 2% of the prescription dose. The mean V(50%) and mean V(100%) to the ipsilateral normal breast were 23.1 ± 11.6% and 9.0 ± 5.8%, respectively. The conformity index of all plans was 1.14 ± 0.04. The maximum dose to the contralateral breast varied from 1.3 cGy to 111 cGy. The mean V(5%) and mean V(30%) to the contralateral and ipsilateral lungs were 1.0 ± 1.6% and 1.3 ± 1.2%, respectively. In our study, the mean V(5%) to the heart was 0.2 ± 0.5% for right-sided tumors and 9.4 ± 10.1% for left-sided tumors. Compared with IMRT and 3D-CRT planning, the PTV coverage from CyberKnife planning was the highest, and the ratio of V(20%) to V(100%) of the breast from CyberKnife planning was the smallest. The heart and lung doses were similar in all the techniques except that the V(5%) for the lung and heart in CyberKnife planning was slightly higher.
CONCLUSIONS: The dosimetric feasibility of APBI using CyberKnife was investigated in this retrospective study. All the dosimetric parameters strictly met the guidelines from the NSABP B39∕RTOG 0413 protocol. With advanced real-time tracking capability, CyberKnife should provide better target coverage and spare nearby critical organs for APBI treatment.

Entities:  

Mesh:

Year:  2012        PMID: 23127056     DOI: 10.1118/1.4757616

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Impact of a Novel Bioabsorbable Implant on Radiation Treatment Planning for Breast Cancer.

Authors:  Michael J Cross; Gail S Lebovic; Joseph Ross; Scott Jones; Arnold Smith; Steven Harms
Journal:  World J Surg       Date:  2017-02       Impact factor: 3.352

Review 2.  Is IORT ready for roll-out?

Authors:  Emanuela Esposito; Bauke Anninga; Ian Honey; Gillian Ross; Dick Rainsbury; Siobhan Laws; Sygriet Rinsma; Michael Douek
Journal:  Ecancermedicalscience       Date:  2015-03-12

3.  Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

Authors:  Erwann Rault; Thomas Lacornerie; Hong-Phuong Dang; Frederik Crop; Eric Lartigau; Nick Reynaert; David Pasquier
Journal:  Radiat Oncol       Date:  2016-02-27       Impact factor: 3.481

4.  Stereotactic Accelerated Partial Breast Irradiation for Early-Stage Breast Cancer: Rationale, Feasibility, and Early Experience Using the CyberKnife Radiosurgery Delivery Platform.

Authors:  Olusola Obayomi-Davies; Thomas P Kole; Bridget Oppong; Sonali Rudra; Erini V Makariou; Lloyd D Campbell; Hozaifa M Anjum; Sean P Collins; Keith Unger; Shawna Willey; Eleni Tousimis; Brian T Collins
Journal:  Front Oncol       Date:  2016-05-23       Impact factor: 6.244

5.  Partial breast irradiation with CyberKnife after breast conserving surgery: a pilot study in early breast cancer.

Authors:  Laura Lozza; Laura Fariselli; Marco Sandri; Mario Rampa; Valentina Pinzi; Maria Carmen De Santis; Marzia Franceschini; Giovanna Trecate; Ilaria Maugeri; Luisa Fumagalli; Francesca Bonfantini; Giulia Bianchi; Emanuele Pignoli; Elena De Martin; Roberto Agresti
Journal:  Radiat Oncol       Date:  2018-03-23       Impact factor: 3.481

6.  Implementation of Stereotactic Accelerated Partial Breast Irradiation Using Cyber-Knife - Technical Considerations and Early Experiences of a Phase II Clinical Study.

Authors:  Norbert Mészáros; Viktor Smanykó; Tibor Major; Gábor Stelczer; Levente Jánváry; Eszter Kovács; Bahéri Mária; Zoltán Zaka; Dávid Pukancsik; Zoltán Takácsi-Nagy; Csaba Polgár
Journal:  Pathol Oncol Res       Date:  2020-05-29       Impact factor: 3.201

7.  Multicatheter interstitial brachytherapy versus stereotactic radiotherapy with CyberKnife for accelerated partial breast irradiation: a comparative treatment planning study with respect to dosimetry of organs at risk.

Authors:  András Herein; Gábor Stelczer; Csilla Pesznyák; Georgina Fröhlich; Viktor Smanykó; Norbert Mészáros; Csaba Polgár; Tibor Major
Journal:  Radiol Oncol       Date:  2021-03-25       Impact factor: 2.991

8.  CyberKnife versus multicatheter interstitial brachytherapy for accelerated partial breast irradiation: a dosimetrical assessment with focus on organs at risk.

Authors:  András Herein; Gábor Stelczer; Csilla Pesznyák; Georgina Fröhlich; Viktor Smanykó; Norbert Mészáros; Csaba Polgár; Zoltán Takácsi-Nagy; Tibor Major
Journal:  Rep Pract Oncol Radiother       Date:  2022-03-22
  8 in total