Literature DB >> 23123643

Carbon fragmentation measurements and validation of the Geant4 nuclear reaction models for hadrontherapy.

M De Napoli1, C Agodi, G Battistoni, A A Blancato, G A P Cirrone, G Cuttone, F Giacoppo, M C Morone, D Nicolosi, L Pandola, V Patera, G Raciti, E Rapisarda, F Romano, D Sardina, A Sarti, A Sciubba, V Scuderi, C Sfienti, S Tropea.   

Abstract

Nuclear fragmentation measurements are necessary when using heavy-ion beams in hadrontherapy to predict the effects of the ion nuclear interactions within the human body. Moreover, they are also fundamental to validate and improve the Monte Carlo codes for their use in planning tumor treatments. Nowadays, a very limited set of carbon fragmentation cross sections are being measured, and in particular, to our knowledge, no double-differential fragmentation cross sections at intermediate energies are available in the literature. In this work, we have measured the double-differential cross sections and the angular distributions of the secondary fragments produced in the (12)C fragmentation at 62 A MeV on a thin carbon target. The experimental data have been used to benchmark the prediction capability of the Geant4 Monte Carlo code at intermediate energies, where it was never tested before. In particular, we have compared the experimental data with the predictions of two Geant4 nuclear reaction models: the Binary Light Ions Cascade and the Quantum Molecular Dynamic. From the comparison, it has been observed that the Binary Light Ions Cascade approximates the angular distributions of the fragment production cross sections better than the Quantum Molecular Dynamic model. However, the discrepancies observed between the experimental data and the Monte Carlo simulations lead to the conclusion that the prediction capability of both models needs to be improved at intermediate energies.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23123643     DOI: 10.1088/0031-9155/57/22/7651

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Experimental validation of proton physics models of Geant4 for calculating stopping power ratio.

Authors:  Ruirui Liu; Xiandong Zhao; Maria Medrano
Journal:  J Radiol Prot       Date:  2022-06-28       Impact factor: 1.559

2.  Report on G4-Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group.

Authors:  P Arce; D Bolst; M-C Bordage; J M C Brown; P Cirrone; M A Cortés-Giraldo; D Cutajar; G Cuttone; L Desorgher; P Dondero; A Dotti; B Faddegon; C Fedon; S Guatelli; S Incerti; V Ivanchenko; D Konstantinov; I Kyriakou; G Latyshev; A Le; C Mancini-Terracciano; M Maire; A Mantero; M Novak; C Omachi; L Pandola; A Perales; Y Perrot; G Petringa; J M Quesada; J Ramos-Méndez; F Romano; A B Rosenfeld; L G Sarmiento; D Sakata; T Sasaki; I Sechopoulos; E C Simpson; T Toshito; D H Wright
Journal:  Med Phys       Date:  2020-12-12       Impact factor: 4.071

Review 3.  Range Verification Methods in Particle Therapy: Underlying Physics and Monte Carlo Modeling.

Authors:  Aafke Christine Kraan
Journal:  Front Oncol       Date:  2015-07-07       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.