Literature DB >> 23118380

Short stems for total hip arthroplasty: initial experience with the Fitmore stem.

K Gustke1.   

Abstract

The use of short stems has become more popular with the increased interest in less invasive approaches for total hip arthroplasty. The curved broaches and stem can be inserted along a curved track to avoid the abductor attachments. Short stems have the potential of being more bone conserving by allowing for higher neck retention, maintenance of the medial greater trochanter, and preferential stress transfer to the proximal femur. An initial experience with 500 new short stems (Fitmore, Zimmer Orthopedics) stems used for total hip arthroplasty is reported. No stems have been revised for aseptic loosening.

Entities:  

Mesh:

Year:  2012        PMID: 23118380     DOI: 10.1302/0301-620X.94B11.30677

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  24 in total

1.  Two- to 4-Year Followup of a Short Stem THA Construct: Excellent Fixation, Thigh Pain a Concern.

Authors:  Richard L Amendola; Devon D Goetz; Steve S Liu; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2017-02       Impact factor: 4.176

2.  Do sex and BMI predict or does stem design prevent muscle damage in anterior supine minimally invasive THA?

Authors:  Benjamin M Frye; Keith R Berend; Adolph V Lombardi; Michael J Morris; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

3.  Clinical outcome of design modifications to the CLS Spotorno Stem in total hip replacement.

Authors:  Angelo Graceffa; Pier Francesco Indelli; Leonardo Latella; Paolo Poli; Alexander Fulco; Massimiliano Marcucci
Journal:  Joints       Date:  2016-09-21

4.  The 'critical trochanter angle' does not show superiority over the CCD angle in predicting varus stem alignment in cementless short-stem total hip arthroplasty.

Authors:  Matthias Luger; Sandra Feldler; Lorenz Pisecky; Jakob Allerstorfer; Tobias Gotterbarm; Antonio Klasan
Journal:  Arch Orthop Trauma Surg       Date:  2022-01-12       Impact factor: 3.067

5.  Primary stability of the Fitmore stem: biomechanical comparison.

Authors:  Wojciech Pepke; Jan Nadorf; Volker Ewerbeck; Marcus R Streit; Stefan Kinkel; Tobias Gotterbarm; Michael W Maier; J Philippe Kretzer
Journal:  Int Orthop       Date:  2013-10-22       Impact factor: 3.075

6.  Low rate of early periprosthetic fractures in cementless short-stem total hip arthroplasty using a minimally invasive anterolateral approach.

Authors:  Matthias Luger; Günter Hipmair; Clemens Schopper; Bernhard Schauer; Rainer Hochgatterer; Jakob Allerstorfer; Tobias Gotterbarm; Antonio Klasan
Journal:  J Orthop Traumatol       Date:  2021-05-21

7.  Comparative Analysis of the Biomechanical Behaviour of Two Cementless Short Stems for Hip Replacement: Linea Anatomic and Minihip.

Authors:  Sergio Gabarre; Antonio Herrera; Elena Ibarz; Jesús Mateo; Jorge Gil-Albarova; Luis Gracia
Journal:  PLoS One       Date:  2016-07-08       Impact factor: 3.240

8.  Cortical hypertrophy with a short, curved uncemented hip stem does not have any clinical impact during early follow-up.

Authors:  Michael W Maier; Marcus R Streit; Moritz M Innmann; Marlis Krüger; Jan Nadorf; J Philippe Kretzer; Volker Ewerbeck; Tobias Gotterbarm
Journal:  BMC Musculoskelet Disord       Date:  2015-12-01       Impact factor: 2.362

Review 9.  Revision rate after short-stem total hip arthroplasty: a systematic review of 49 studies.

Authors:  Jakob van Oldenrijk; Jeroen Molleman; Michel Klaver; Rudolf W Poolman; Daniel Haverkamp
Journal:  Acta Orthop       Date:  2014-04-03       Impact factor: 3.717

10.  Influence of patient-related characteristics on early migration in calcar-guided short-stem total hip arthroplasty: a 2-year migration analysis using EBRA-FCA.

Authors:  Karl Philipp Kutzner; Mark Predrag Kovacevic; Tobias Freitag; Andreas Fuchs; Heiko Reichel; Ralf Bieger
Journal:  J Orthop Surg Res       Date:  2016-03-07       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.