Literature DB >> 23117649

Intra and inter-rater reliability of infrared image analysis of masticatory and upper trapezius muscles in women with and without temporomandibular disorder.

Ana C S Costa1, Almir V Dibai Filho, Amanda C Packer, Delaine Rodrigues-Bigaton.   

Abstract

BACKGROUND: Infrared thermography is an aid tool that can be used to evaluate several pathologies given its efficiency in analyzing the distribution of skin surface temperature.
OBJECTIVES: To propose two forms of infrared image analysis of the masticatory and upper trapezius muscles, and to determine the intra and inter-rater reliability of both forms of analysis.
METHOD: Infrared images of masticatory and upper trapezius muscles of 64 female volunteers with and without temporomandibular disorder (TMD) were collected. Two raters performed the infrared image analysis, which occurred in two ways: temperature measurement of the muscle length and in central portion of the muscle. The Intraclass Correlation Coefficient (ICC) was used to determine the intra and inter-rater reliability.
RESULTS: The ICC showed excellent intra and inter-rater values for both measurements: temperature measurement of the muscle length (TMD group, intra-rater, ICC ranged from 0.996 to 0.999, inter-rater, ICC ranged from 0.992 to 0.999; control group, intra-rater, ICC ranged from 0.993 to 0.998, inter-rater, ICC ranged from 0.990 to 0.998), and temperature measurement of the central portion of the muscle (TMD group, intra-rater, ICC ranged from 0.981 to 0.998, inter-rater, ICC ranged from 0.971 to 0.998; control group, intra-rater, ICC ranged from 0.887 to 0.996, inter-rater, ICC ranged from 0.852 to 0.996).
CONCLUSION: The results indicated that temperature measurements of the masticatory and upper trapezius muscles carried out by the analysis of the muscle length and central portion yielded excellent intra and inter-rater reliability.

Entities:  

Mesh:

Year:  2012        PMID: 23117649     DOI: 10.1590/s1413-35552012005000058

Source DB:  PubMed          Journal:  Braz J Phys Ther        ISSN: 1413-3555            Impact factor:   3.377


  10 in total

1.  Accuracy and Reliability of Infrared Thermography in Assessment of the Breasts of Women Affected by Cancer.

Authors:  Rinaldo Roberto de Jesus Guirro; Maíta Marade Oliveira Lima Leite Vaz; Lais Mara Siqueira das Neves; Almir Vieira Dibai-Filho; Hélio Humberto Angotti Carrara; Elaine Caldeira de Oliveira Guirro
Journal:  J Med Syst       Date:  2017-04-12       Impact factor: 4.460

2.  Inter and Intra-Rater Reliability of Short-Term Measurement of Heart Rate Variability on Rest in Diabetic Type 2 Patients.

Authors:  Daniela Bassi; Aldair Darlan Santos-de-Araújo; Patrícia Faria Camargo; Almir Vieira Dibai-Filho; Moyrane Abreu da Fonseca; Renata Gonçalves Mendes; Audrey Borghi-Silva
Journal:  J Med Syst       Date:  2018-10-16       Impact factor: 4.460

3.  Combined effectiveness of extracorporeal radial shockwave therapy and ultrasound-guided trigger point injection of lidocaine in upper trapezius myofascial pain syndrome.

Authors:  Nadia Anwar; Shuangyu Li; Lu Long; Li Zhou; Meng Fan; Yi Zhou; Sanrong Wang; Lehua Yu
Journal:  Am J Transl Res       Date:  2022-01-15       Impact factor: 4.060

4.  Artificial intelligence and infrared thermography as auxiliary tools in the diagnosis of temporomandibular disorder.

Authors:  Elisa Diniz de Lima; José Alberto Souza Paulino; Ana Priscila Lira de Farias Freitas; José Eraldo Viana Ferreira; Jussara da Silva Barbosa; Diego Filipe Bezerra Silva; Patrícia Meira Bento; Ana Marly Araújo Maia Amorim; Daniela Pita Melo
Journal:  Dentomaxillofac Radiol       Date:  2021-10-06       Impact factor: 2.419

5.  Evolution of Skin Temperature after the Application of Compressive Forces on Tendon, Muscle and Myofascial Trigger Point.

Authors:  Marina Figueiredo Magalhães; Almir Vieira Dibai-Filho; Elaine Caldeira de Oliveira Guirro; Carlos Eduardo Girasol; Alessandra Kelly de Oliveira; Fabiana Rodrigues Cancio Dias; Rinaldo Roberto de Jesus Guirro
Journal:  PLoS One       Date:  2015-06-12       Impact factor: 3.240

6.  Validation and Test-Retest Reliability of New Thermographic Technique Called Thermovision Technique of Dry Needling for Gluteus Minimus Trigger Points in Sciatica Subjects and TrPs-Negative Healthy Volunteers.

Authors:  Elżbieta Skorupska; Michał Rychlik; Włodzimierz Samborski
Journal:  Biomed Res Int       Date:  2015-06-07       Impact factor: 3.411

7.  Women with more severe degrees of temporomandibular disorder exhibit an increase in temperature over the temporomandibular joint.

Authors:  Almir Vieira Dibai-Filho; Ana Cláudia de Souza Costa; Amanda Carine Packer; Ester Moreira de Castro; Delaine Rodrigues-Bigaton
Journal:  Saudi Dent J       Date:  2014-12-13

8.  Reliability of different methodologies of infrared image analysis of myofascial trigger points in the upper trapezius muscle.

Authors:  Almir V Dibai-Filho; Elaine C O Guirro; Vânia T K Ferreira; Hugo E Brandino; Maíta M O L L Vaz; Rinaldo R J Guirro
Journal:  Braz J Phys Ther       Date:  2015-04-27       Impact factor: 3.377

9.  Correlation between skin temperature in the lower limbs and biochemical marker, performance data, and clinical recovery scales.

Authors:  Gabriela de Carvalho; Carlos Eduardo Girasol; Luiz Guilherme Cruz Gonçalves; Elaine Caldeira Oliveira Guirro; Rinaldo Roberto de Jesus Guirro
Journal:  PLoS One       Date:  2021-03-18       Impact factor: 3.240

10.  Infrared thermography in pain medicine.

Authors:  Francis Sahngun Nahm
Journal:  Korean J Pain       Date:  2013-07-01
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.