Literature DB >> 25993626

Reliability of different methodologies of infrared image analysis of myofascial trigger points in the upper trapezius muscle.

Almir V Dibai-Filho1, Elaine C O Guirro1, Vânia T K Ferreira1, Hugo E Brandino1, Maíta M O L L Vaz1, Rinaldo R J Guirro1.   

Abstract

BACKGROUND: Infrared thermography is recognized as a viable method for evaluation of subjects with myofascial pain.
OBJECTIVE: The aim of the present study was to assess the intra- and inter-rater reliability of infrared image analysis of myofascial trigger points in the upper trapezius muscle.
METHOD: A reliability study was conducted with 24 volunteers of both genders (23 females) between 18 and 30 years of age (22.12 ± 2.54), all having cervical pain and presence of active myofascial trigger point in the upper trapezius muscle. Two trained examiners performed analysis of point, line, and area of the infrared images at two different periods with a 1-week interval. The intra-class correlation coefficient (ICC(2,1)) was used to assess the intra- and inter-rater reliability.
RESULTS: With regard to the intra-rater reliability, ICC values were between 0.591 and 0.993, with temperatures between 0.13 and 1.57 °C for values of standard error of measurement (SEM) and between 0.36 and 4.35 °C for the minimal detectable change (MDC). For the inter-rater reliability, ICC ranged from 0.615 to 0.918, with temperatures between 0.43 and 1.22 °C for the SEM and between 1.19 and 3.38 °C for the MDC.
CONCLUSION: The methods of infrared image analyses of myofascial trigger points in the upper trapezius muscle employed in the present study are suitable for clinical and research practices.

Entities:  

Mesh:

Year:  2015        PMID: 25993626      PMCID: PMC4481832          DOI: 10.1590/bjpt-rbf.2014.0076

Source DB:  PubMed          Journal:  Braz J Phys Ther        ISSN: 1413-3555            Impact factor:   3.377


Introduction

Myofascial trigger points are structures found in skeletal muscles that present with some type of dysfunction. Conceptually, they are nodules hypersensitive to palpation due to pain, change in muscular activity, limitation in joint mobility, and autonomic manifestations1. In addition, the literature suggests that the physiopathological mechanism of myofascial trigger points is related to changes in muscular activity and the repercussions for blood circulation and local metabolism2 , 3. Myofascial trigger points may present as active or latent. The active points are hypersensitive points that trigger pain recognized as familiar by the patient during the application of compressive force; in turn, latent points are clinically quiescent with respect to spontaneous pain, generating unfamiliar pain2. The active myofascial trigger points also differ by the presence of different algesic substances, such as bradykinin, substance P, and serotonin3. Recent studies4 - 6 have used the criteria set by Simons et al.7 for the correct diagnosis of myofascial trigger points based on muscle palpation. However, other authors highlight that palpation requires a combination of skill, training, and critical clinical practice8. In addition, other instruments may be applied for evaluation of subjects with myofascial trigger points, such as ultrasonography9, sonoelastography10, and electromyography11. However, despite advances in diagnostic technology, physical examination remains the most accepted method of evaluation of myofascial trigger points due to the limited clinical applicability of the new instruments. Within this context and considering both autonomic and metabolic repercussions resulting from the presence of myofascial trigger points2, infrared thermography is recognized as another viable method for the evaluation of subjects with myofascial pain, according to studies conducted by Hakgüder et al.12 and Haddad et al.13. This is a non-invasive method for evaluating the behavior of body skin temperature14, which is dependent on microcirculatory, metabolic, and autonomic activities15 , 16. In general, infrared images can be evaluated in two ways: qualitatively, in which an experienced examiner gives an opinion based on the visual analysis of the image17 , 18; and quantitatively, in which body skin regions of interest are measured by means of specific software. According to the literature, the latter is the most used form13 , 19 - 21. However, despite the studies using infrared thermography in subjects with myofascial pain, there is a lack of standardization in the method of infrared image analysis, as reported by Costa et al.21. In light of this, the objective of the present study was to assess the intra- and inter-rater reliability of infrared image analyses of myofascial trigger points in the upper trapezius muscle. The hypothesis tested herein is that the methodologies for the analysis of infrared images show reliability that endorses its use in clinical practice and research.

Method

Sample

A sample size calculation was performed with a confidence coefficient of 0.95 and a range of the confidence interval (CI) for the intraclass correlation coefficient (ICC) of 0.30. Fleiss's22 coefficients were also calculated to detect substantial reliability (ICC=0.76)22. Therefore, a sample size of 24 volunteers was estimated. The sample size calculation was based on the study conducted by Bonett23. The target population of this study was recruited from the university community of Ribeirão Preto, SP, Brazil, by means of verbal invitation and posters. The inclusion criteria were the following: age group between 18 and 30 years old; both genders; presence of neck pain24, anatomically defined as pain within the region limited by the superior nuchal line, the lateral margins of the cervical vertebrae and an imaginary transverse line immediately above the first thoracic spinous process25, which was identified by a Neck Disability Index (NDI) score ≥5 points26 , 27 and a score ≥3 points according to the Numeric Pain Rating Scale28; use of computer for at least 2 hours daily29; and the presence of active myofascial trigger point, unilateral and of central location30 in the upper trapezius muscle on the same side of the dominance of the upper limb. The diagnosis of the myofascial trigger point was performed only once according to the criteria established by Simons et al.7 and Gerwin et al.31: 1) presence of a palpable taut band in a skeletal muscle, 2) presence of a hypersensitive tender spot within the taut band, 3) local twitch response elicited by the snapping palpation of the taut band, and 4) reproduction of referred pain in response to myofascial trigger point compression. These criteria were found to have good levels of inter-rater reliability31. Myofascial trigger point was considered active if local and spontaneous pain evoked by digital compression was recognized as familiar pain by the volunteer32. The exclusion criteria were the following: volunteers with history of cervical trauma; surgery of the head, face or neck; cervical disc disease; degenerative diseases of the spine; physical therapeutic treatment in the past 3 months; use of analgesics, anti-inflammatories or muscle relaxants in the past week; presence of systemic diseases; diagnosis of fibromyalgia; body mass index (BMI) greater than 25 kg/m2. The procedures of the present study were approved by the Research Ethics Committee of Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto da Universidade de São Paulo (USP), Ribeirão Preto, SP, Brazil, according to protocol number 030643/2013. Each volunteer signed a consent form.

Infrared thermography

Myofascial trigger points do not show a pattern of identification when analyzed by infrared imaging. Therefore, to ensure that the skin temperature was measured precisely on the myofascial trigger points, we initially performed palpation and identification of the myofascial trigger point centrally located30 in the upper trapezius muscle according to the diagnostic criteria of Simons et al.7 and Gerwin et al.31; next, four Styrofoam markers measuring 8 mm in diameter were used because of their isolating characteristic, positioned equidistantly at a distance of 25 mm from the center of the myofascial trigger point (Figure 1); after these procedures, the volunteers remained seated and at rest for 15 minutes in a room with controlled environment at a temperature of 22°±2°C and humidity of 50%, as established by Roy et al.33; and finally, three infrared images were sequentially captured at a distance of 100 cm from the subject and perpendicular to the myofascial trigger point12 , 21, thus allowing the muscle to be framed.
Figure 1.

Styrofoam markers used to delineate the myofascial trigger point in the upper trapezius muscle.

The room used for the thermographic examination was lit with fluorescent lamps, without the presence of electrical equipment generating heat and no incidence of sunlight or airflow on the volunteer33. The subjects were instructed to avoid taking a hot bath or shower, using topical agents such as creams or talc, practicing physical exercises, and ingesting stimulating substances such as caffeine, nicotine or chocolate during the two hours before data collection19 , 21. During the collection procedures, the volunteers remained seated on a bench, with their trunk erect, hands on the thighs, and staring ahead. They were asked to let the region of the muscle being evaluated free of clothes or personal items, such as earrings or necklaces, in addition to keeping their hair tied up. A thermal camera (T300, FLIR Systems, Wilsonville, OR, USA) was used to capture infrared images, operating with precision of up to 0.05 °C, emissivity of 0.98. The device was stabilized for 10 min prior to the reading.

Analysis of infrared images

All analyses were conducted by using the QuickReport software, version 1.2 (FLIR Systems). Two examiners, who had previously received training with infrared thermography, performed the measurements of the images twice with a 1-week interval34, thus making it possible to assess the intra- and inter-rater reliability of the infrared image analyses. Based on the analysis features of the software used in the present study, three forms of measurement of the skin temperature were performed over the myofascial trigger point: point analysis, in which the temperature of the central point of the area delimited by the markers was measured (Figure 2A); line analysis, in which a straight-line linking two markers was drawn across the region where the trigger point was located (Figure 2B); and area analysis, in which the area delimited by the four markers was established (Figure 2C). Initially, the mean values of skin temperature for the three analyses were calculated. Next, minimum and maximum values were considered for line and area analyses.
Figure 2.

Analyses for point (A), line (B), and area (C) of the myofascial trigger point in the upper trapezius muscle.

Statistical analysis

Intraclass correlation coefficient (ICC2,1) was used to determine the intra- and inter-rater reliability, with its respective 95% confidence interval (CI 95%) , standard error of measurement (SEM), and minimum detectable change (MDC)35. Interpretation of ICC values was based on that suggested by Fleiss22. For values less than 0.40, the reliability was considered low; between 0.40 to 0.75, moderate; between 0.75 to 0.90, substantial; and finally, values greater than 0.90, excellent. All statistical analyses were performed using the SPSS software, version 17.0 (Chicago, IL, USA).

Results

According to the eligibility criteria, twenty-eight volunteers were recruited from the university community. However, four volunteers were excluded from the study due to an NDI score of less than 5 points, thus resulting in a final sample of 24 subjects of both genders (23 females), 22 right-handed, mean age of 22.12 (SD=2.54) years, mean BMI of 21.04 (SD=1.95) kg/cm2, mean NDI score of 10.41 (SD=3.18) points, mean pain intensity of 5.00 (SD=1.66) points, and mean duration of cervical pain of 39.33 (SD=33.26) weeks. Table 1 lists the values of intra-rater reliability, showing excellent reliability for point analysis (mean value), line analysis (mean and maximum values), and area analysis (mean, minimum, and maximum values), with ICC values ranging between 0.943 and 0.993. In addition, there was a moderate reliability for line analysis (minimum value), with ICC value equal to 0.591, and substantial reliability for area analysis (minimum value), with ICC value equal to 0.821. With respect to the SEM, there was variation in values between 0.13 and 1.57 °C. In turn, the MDC values ranged from 0.36 to 4.35 °C.
Table 1.

Intra-rater reliability of the minimum, maximum, and mean values of skin temperature for point, line, and area analyses in the myofascial trigger point.

AnalysisValuesICC95% CISEMMDC
Point Mean 0.955* 0.928-0.972 0.34 0.94
Line Minimum Maximum Mean 0.591* 0.963* 0.993* 0.346-0.744 0.942-0.977 0.989-0.996 1.57 0.28 0.13 4.35 0.78 0.36
Area Minimum Maximum Mean 0.821* 0.943* 0.947* 0.714-0.888 0.909-0.964 0.915-0.967 0.66 0.32 0.16 1.83 0.89 0.44

ICC: Intra-class correlation coefficient; CI: Confidence interval; SEM: Standard error of measurement (in °C); MDC: Minimum detectable change (in °C).

p<0.001.

ICC: Intra-class correlation coefficient; CI: Confidence interval; SEM: Standard error of measurement (in °C); MDC: Minimum detectable change (in °C). p<0.001. Table 2 lists the values of inter-rater reliability, showing excellent reliability for point and line analysis (mean value), with ICC values equal to 0.908 and 0.918, respectively. For the other measures, there was moderate to substantial reliability, with ICC values ranging from 0.615 to 0.894. With respect to the SEM, there was variation in values between 0.43 and 1.22 °C. In turn, the MDC values ranged from 1.19 to 3.38 °C.
Table 2.

Inter-rater reliability of the minimum, maximum, and mean values of skin temperature for point, line, and area analyses in the myofascial trigger point.

AnalysisValuesICC95% CISEMMDC
Point Mean 0.908* 0.853-0.942 0.48 1.33
Line Minimum Maximum Mean 0.615* 0.864* 0.918* 0.348-0.759 0.783-0.915 0.869-0.949 1.22 0.52 0.43 3.38 1.44 1.19
Area Minimum Maximum Mean 0.809* 0.851* 0.894* 0.695-0.880 0.762-0.907 0.831-0.934 0.62 0.50 0.44 1.72 1.39 1.22

ICC: Intra-class correlation coefficient; CI: Confidence interval; SEM: Standard error of measurement (in °C); MDC: Minimum detectable change (in °C).

p<0.001.

ICC: Intra-class correlation coefficient; CI: Confidence interval; SEM: Standard error of measurement (in °C); MDC: Minimum detectable change (in °C). p<0.001.

Discussion

In the present study, the intra- and inter-rater reliability of infrared image analyses by using point, line, and area approaches had substantial to excellent ICC values, except the minimum value for line analysis, as moderate ICC values were observed for intra- and inter-rate analyses. The results of the present study are in partial accordance with those reported by Costa et al.21, who found excellent intra- and inter-rater reliability for point and line analyses regarding the masseter, temporalis anterior, suprahyoid, and upper trapezius muscles in individuals with or without temporomandibular disorder. However, it should be pointed out that these authors were not assessing myofascial trigger points in the skeletal muscles in question as their aim was to investigate skin temperature on the muscle belly. Point analysis was also employed by Rodrigues-Bigaton et al.36 for assessment of skin temperature in the temporomandibular joint of individuals with and without arthralgia, with ICC values ranging from 0.841 to 0.874. Rodrigues-Bigaton et al.37 also used area analysis of the masseter and temporalis anterior muscle belly in both individuals with temporomandibular disorder and controls, reporting ICC values ranging from 0.945 to 0.998. Some studies assessed the reliability of the infrared thermography in other clinical conditions, reporting results similar to those found in the present study. In the analysis of skin temperature regarding the paraspinal region, McCoy et al.38 found excellent intra- and inter-rater reliability. Choi et al.39 observed a high inter-rater reliability in the assessment of individuals with complex regional pain syndrome. In addition to these studies, Zaproudina et al.40 found high ICC values for inter-rater reliability in healthy subjects, however these authors identified reasonable ICC values when considering the temperature of the extremities on different days. The studies conducted by Costa et al.21, Rodrigues-Bigaton et al.36, and Rodrigues-Bigaton et al.37 were based on the mean value of analyses performed for measurement of the skin temperature. Within this context, Klamann et al.41 assessed the intra-rater reliability of the temperature analysis of ocular surface, reporting ICC values of 0.947, 0.949, and 0.955 for minimum, maximum, and mean values, respectively. In the present study, not only the mean value was used but also minimum and maximum values of line and area analyses. Regarding the values of SEM and MDC, published studies that evaluated the reliability of infrared thermography showed no such statistical measures21 , 37 - 40. In the present study, when considering the intra-rater reliability, higher SEM and MDC were observed for the minimum value of line (1.57 and 4.35 °C) and area (0.66 and 1.83) analyses. For inter-rater reliability, similar results were found, with higher SEM and MDC for the minimum value of the line (1.22 and 3.38 °C) and area (0.62 and 1.72 °C) analyses. Thus, in general, mean (point, line, and area analyses) and maximum (line and area analyses) measures are the most reliable (intra-rater, ICC between 0.943 and 0.993; inter-rater, ICC between 0.851 and 0.918) and with less error (intra-rater, SEM between 0.13 and 0.34 °C, and MDC between 0.36 and 0.94 °C; inter-rater, SEM between 0.43 and 0.52 °C, and MDC between 1.19 and 1.44 °C). Moreover, in a more rigorous analysis of ICC values, considering the lower limit of the CI 95% and excepting the minimum values of the area and line analyzes, excellent intra-rater reliability (ICC values between 0.909 and 0.989) and substantial inter-rater reliability (ICC values between 0.762 and 0.869) were observed. These results give more robustness to the applicability of the methods of analyses (mean and maximum values) of the infrared images. Considering the relevance of SEM and MDC in reliability studies, Tucci et al.35 evaluated a specific test for identification of shoulder impingement syndrome and also found that previously published studies in the same subject did not consider these statistical measures in reliability analysis. In addition, these authors emphasize the importance of knowing the values for SEM and MDC as these numbers give a good indication of the minimal score difference between evaluations that could be considered as real improvement. Finally, infrared thermography has been employed for the evaluation of different musculoskeletal conditions42 - 44. Therefore, the aim of the present study was to standardize the infrared image analyses of myofascial trigger points, thus making it possible to support the use of infrared thermography in clinical practice and research for either mapping the skin temperature of a given site or even for assessing the effects of therapeutic resources in musculoskeletal dysfunctions4 , 6 , 12. The present study had the limitation of not including volunteers with latent myofascial trigger points, since these differ from the active ones due to the presence of algesic substances, among other features3. Moreover, we suggest that future studies assess the reliability of the entire procedure of collecting thermographic data: patient preparation, instrumentation, recording, and analysis of the infrared images.

Conclusion

The methods of infrared image analysis of myofascial trigger points in the upper trapezius muscle proposed by the present study showed acceptable intra- and inter-rater reliability values, which supports the use of these methodologies in clinical and research practices.
  40 in total

1.  Latent myofascial trigger points are associated with an increased antagonistic muscle activity during agonist muscle contraction.

Authors:  José Miota Ibarra; Hong-You Ge; Chao Wang; Vicente Martínez Vizcaíno; Thomas Graven-Nielsen; Lars Arendt-Nielsen
Journal:  J Pain       Date:  2011-11-11       Impact factor: 5.820

2.  Understanding the vascular environment of myofascial trigger points using ultrasonic imaging and computational modeling.

Authors:  Siddhartha Sikdar; Robin Ortiz; Tadesse Gebreab; Lynn H Gerber; Jay P Shah
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

3.  Measurement of dynamic ocular surface temperature in healthy subjects using a new thermography device.

Authors:  Matthias K J Klamann; Anna-Karina B Maier; Johannes Gonnermann; Julian P Klein; Uwe Pleyer
Journal:  Curr Eye Res       Date:  2012-05-04       Impact factor: 2.424

4.  Prevalence and anatomical localization of muscle referred pain from active trigger points in head and neck musculature in adults and children with chronic tension-type headache.

Authors:  Cristina Alonso-Blanco; César Fernández-de-las-Peñas; Daniel M Fernández-Mayoralas; Ana Isabel de-la-Llave-Rincón; Juan A Pareja; Peter Svensson
Journal:  Pain Med       Date:  2011-08-03       Impact factor: 3.750

5.  An exploratory thermographic investigation of the effects of connective tissue massage on autonomic function.

Authors:  Liz A Holey; John Dixon; James Selfe
Journal:  J Manipulative Physiol Ther       Date:  2011-07-23       Impact factor: 1.437

6.  Assessment of the upper trapezius muscle temperature in women with and without neck pain.

Authors:  Almir Vieira Dibai Filho; Amanda Carine Packer; Ana Cláudia de Souza Costa; Kelly Cristina dos Santos Berni-Schwarzenbeck; Delaine Rodrigues-Bigaton
Journal:  J Manipulative Physiol Ther       Date:  2012-05-17       Impact factor: 1.437

7.  Objective sonographic measures for characterizing myofascial trigger points associated with cervical pain.

Authors:  Jeffrey J Ballyns; Jay P Shah; Jennifer Hammond; Tadesse Gebreab; Lynn H Gerber; Siddhartha Sikdar
Journal:  J Ultrasound Med       Date:  2011-10       Impact factor: 2.153

8.  Validity of four pain intensity rating scales.

Authors:  Maria Alexandra Ferreira-Valente; José Luís Pais-Ribeiro; Mark P Jensen
Journal:  Pain       Date:  2011-10       Impact factor: 6.961

Review 9.  Latent myofascial trigger points.

Authors:  Hong-You Ge; Lars Arendt-Nielsen
Journal:  Curr Pain Headache Rep       Date:  2011-10

10.  Intra-examiner and inter-examiner reproducibility of paraspinal thermography.

Authors:  Matthew McCoy; Ismay Campbell; Pamela Stone; Curtis Fedorchuk; Sameera Wijayawardana; Kirk Easley
Journal:  PLoS One       Date:  2011-02-11       Impact factor: 3.240

View more
  8 in total

1.  Accuracy and Reliability of Infrared Thermography in Assessment of the Breasts of Women Affected by Cancer.

Authors:  Rinaldo Roberto de Jesus Guirro; Maíta Marade Oliveira Lima Leite Vaz; Lais Mara Siqueira das Neves; Almir Vieira Dibai-Filho; Hélio Humberto Angotti Carrara; Elaine Caldeira de Oliveira Guirro
Journal:  J Med Syst       Date:  2017-04-12       Impact factor: 4.460

2.  Inter and Intra-Rater Reliability of Short-Term Measurement of Heart Rate Variability on Rest in Diabetic Type 2 Patients.

Authors:  Daniela Bassi; Aldair Darlan Santos-de-Araújo; Patrícia Faria Camargo; Almir Vieira Dibai-Filho; Moyrane Abreu da Fonseca; Renata Gonçalves Mendes; Audrey Borghi-Silva
Journal:  J Med Syst       Date:  2018-10-16       Impact factor: 4.460

3.  Evolution of Skin Temperature after the Application of Compressive Forces on Tendon, Muscle and Myofascial Trigger Point.

Authors:  Marina Figueiredo Magalhães; Almir Vieira Dibai-Filho; Elaine Caldeira de Oliveira Guirro; Carlos Eduardo Girasol; Alessandra Kelly de Oliveira; Fabiana Rodrigues Cancio Dias; Rinaldo Roberto de Jesus Guirro
Journal:  PLoS One       Date:  2015-06-12       Impact factor: 3.240

4.  Application of shortwave diathermy to lower limb increases arterial blood flow velocity and skin temperature in women: a randomized controlled trial.

Authors:  Natanael Teixeira Alves De Sousa; Elaine Caldeira De Oliveira Guirro; João Guilherme Calió; Mariane Cristina De Queluz; Rinaldo Roberto De Jesus Guirro
Journal:  Braz J Phys Ther       Date:  2017-03-21       Impact factor: 3.377

5.  Thermal Condition of Muscle Area Around the Temporomandibular Joint in Patient with Systemic Lupus Erythematosus Using Infrared Thermography Application: A Case Report.

Authors:  Liana Rahmayani; Mustanir Yahya; Cut Soraya; Saumi Syahreza
Journal:  J Int Soc Prev Community Dent       Date:  2020-09-28

6.  Correlation between skin temperature in the lower limbs and biochemical marker, performance data, and clinical recovery scales.

Authors:  Gabriela de Carvalho; Carlos Eduardo Girasol; Luiz Guilherme Cruz Gonçalves; Elaine Caldeira Oliveira Guirro; Rinaldo Roberto de Jesus Guirro
Journal:  PLoS One       Date:  2021-03-18       Impact factor: 3.240

7.  Construct validity and reliability of the 2-minute step test in patients with knee osteoarthritis.

Authors:  Thiago Felipe de Morais Almeida; Almir Vieira Dibai-Filho; Fernanda de Freitas Thomaz; Eloiza Adelaide Amaral Lima; Christian Emmanuel Torres Cabido
Journal:  BMC Musculoskelet Disord       Date:  2022-02-17       Impact factor: 2.362

8.  Occupational Risk Evaluation Through Infrared Thermography: Development and Proposal of a Rapid Screening Tool for Risk Assessment Arising from Repetitive Actions of the Upper Limbs.

Authors:  André Luiz Soares; Antonio Augusto de Paula Xavier; Ariel Orlei Michaloski
Journal:  Int J Environ Res Public Health       Date:  2020-05-13       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.