Literature DB >> 23117608

0.1T magnetic resonance image in the study of experimental hydrocephalus in rats. Accuracy of the method in the measurements of the ventricular size.

Samuel Caputo de Castro1, Hélio Rubens Machado, Carlos Henrique Rocha Catalão, Betina Aisengart de Siqueira, Ana Leda Bertoncini Simões, João-José Lachat, Luiza da Silva Lopes.   

Abstract

PURPOSE: To investigate the accuracy of 1.0T Magnetic Resonance Imaging (MRI) to measure the ventricular size in experimental hydrocephalus in pup rats.
METHODS: Wistar rats were subjected to hydrocephalus by intracisternal injection of 20% kaolin (n=13). Ten rats remained uninjected to be used as controls. At the endpoint of experiment animals were submitted to MRI of brain and killed. The ventricular size was assessed using three measures: ventricular ratio (VR), the cortical thickness (Cx) and the ventricles area (VA), performed on photographs of anatomical sections and MRI.
RESULTS: The images obtained through MR present enough quality to show the lateral ventricular cavities but not to demonstrate the difference between the cortex and the white matter, as well as the details of the deep structures of the brain. There were no statistically differences between the measures on anatomical sections and MRI of VR and Cx (p=0.9946 and p=0.5992, respectively). There was difference between VA measured on anatomical sections and MRI (p<0.0001).
CONCLUSION: The parameters obtained through 1.0T MRI were sufficient in quality to individualize the ventricular cavities and the cerebral cortex, and to calculate the ventricular ratio in hydrocephalus rats when compared to their respective anatomic slice.

Entities:  

Mesh:

Year:  2012        PMID: 23117608     DOI: 10.1590/s0102-86502012001100005

Source DB:  PubMed          Journal:  Acta Cir Bras        ISSN: 0102-8650            Impact factor:   1.388


  2 in total

1.  Ventricular-subcutaneous shunt for the treatment of experimental hydrocephalus in young rats: technical note.

Authors:  Marcelo Volpon Santos; Camila Araujo Bernardino Garcia; Evelise Oliveira Jardini; Thais Helena Romeiro; Luiza da Silva Lopes; Hélio Rubens Machado; Ricardo Santos de Oliveira
Journal:  Childs Nerv Syst       Date:  2016-02-23       Impact factor: 1.475

2.  Edaravone reduces astrogliosis and apoptosis in young rats with kaolin-induced hydrocephalus.

Authors:  Camila Araújo Bernardino Garcia; Carlos Henrique Rocha Catalão; Hélio Rubens Machado; Ivair Matias Júnior; Thais Helena Romeiro; José Eduardo Peixoto-Santos; Marcelo Volpon Santos; Luiza da Silva Lopes
Journal:  Childs Nerv Syst       Date:  2016-12-17       Impact factor: 1.475

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.