Literature DB >> 2311623

81mKr equilibrium radionuclide ventriculography for the assessment of right heart function.

R M Oliver1, J M Gray, V F Challenor, J S Fleming, D G Waller.   

Abstract

Right heart 81mKr equilibrium radionuclide ventriculography was used to derive right ventricular ejection fraction (RVEF) in 12 healthy male volunteers. Anatomical lung subtraction using 99mTc-MAA perfusion scintigraphy was compared with conventional background correction and the effect of imaging projection on the techniques of image analysis evaluated. Both intra and inter observer variability were reduced by anatomical lung subtraction when compared to conventional background correction. In the right anterior oblique (RAO) projection, background corrected RVEF was lower than lung subtracted RVEF - 0.544 +/- 0.05 and 0.612 +/- 0.08 (mean +/- SD) (P less than 0.02). Lung subtracted RVEF in the anterior projection was lower than that with background correction (P less than 0.05) and lower than lung subtracted RVEF in the RAO projection (P less than 0.001). We conclude that optimal separation of right heart structures is achieved in the RAO projection and that reproducibility of the analytical technique is improved by anatomical lung subtraction.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2311623     DOI: 10.1007/bf01465916

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  17 in total

1.  Evaluation of the accuracy of steady-state krypton-81m method for calculating right ventricular ejection fraction.

Authors:  H R Ham; P R Franken; B Georges; E Delcourt; M Guillaume; A Piepsz
Journal:  J Nucl Med       Date:  1986-05       Impact factor: 10.057

2.  A new technique for assessing right ventricular ejection fraction using rapid multiple-gated equilibrium cardiac blood pool scintigraphy. Description, validation and findings in chronic coronary artery disease.

Authors:  J Maddahi; D S Berman; D T Matsuoka; A D Waxman; K E Stankus; J S Forrester; H J Swan
Journal:  Circulation       Date:  1979-09       Impact factor: 29.690

3.  Krypton-81m imaging of the right ventricle.

Authors:  M Horn; K Witztum; C Neveu; G Perkins; B Walsh
Journal:  J Nucl Med       Date:  1985-01       Impact factor: 10.057

4.  Right-ventricular function as assessed by two radionuclide techniques: concise communication.

Authors:  J A Harolds; R B Grove; R D Bowen; T A Powers
Journal:  J Nucl Med       Date:  1981-02       Impact factor: 10.057

5.  Hemodynamic correlates of right ventricular ejection fraction measured with gated radionuclide angiography.

Authors:  K S Korr; E J Gandsman; M L Winkler; R S Shulman; E W Bough
Journal:  Am J Cardiol       Date:  1982-01       Impact factor: 2.778

6.  An improved method of right ventricular gated equilibrium blood pool radionuclide ventriculography.

Authors:  D Morrison; J Marshall; A L Wright; M Daly; R Henry
Journal:  Chest       Date:  1982-11       Impact factor: 9.410

7.  Assessment of right ventricular function at rest and during exercise in patients with coronary heart disease: a new approach using equilibrium radionuclide angiography.

Authors:  R Slutsky; W Hooper; K Gerber; A Battler; V Froelicher; W Ashburn; J Karliner
Journal:  Am J Cardiol       Date:  1980-01       Impact factor: 2.778

8.  Can right ventricular performance be assessed by equilibrium radionuclide ventriculography?

Authors:  Q F Xue; W MacNee; D C Flenley; W J Hannan; C J Adie; A L Muir
Journal:  Thorax       Date:  1983-07       Impact factor: 9.139

9.  Evaluation of right-ventricular function by gated blood-pool scintigraphy.

Authors:  V Legrand; M Chevigne; J Foulon; P Rigo
Journal:  J Nucl Med       Date:  1983-10       Impact factor: 10.057

10.  Right Ventricular function in aortic and mitral valve disease.

Authors:  G G Winzelberg; C A Boucher; G M Pohost; K A McKusick; J B Bingham; R D Okada; H W Strauss
Journal:  Chest       Date:  1981-05       Impact factor: 9.410

View more
  2 in total

Review 1.  First-pass radionuclide angiocardiography with single-crystal gamma cameras.

Authors:  K Nichols; E G DePuey; A Rozanski
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

2.  Normal right ventricular systolic and diastolic function assessed by krypton-81m equilibrium ventriculography.

Authors:  R M Oliver; J S Fleming; K D Dawkins; D G Waller
Journal:  Int J Card Imaging       Date:  1993-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.