Literature DB >> 23115724

Rapid Detection of Escherichia coli O157: H7 by Fluorescent Amplification-Based Specific Hybridization (FLASH) PCR.

F Khatami1, M Heidari, M Khatami.   

Abstract

BACKGROUND: Escherichia coli O157:H7 is an enteric pathogen which can be frequently found asymptomatically in ruminant mammals, but can cause diseases from mild diarrhea to hemolytic uremic syndrome in humans.
METHODS: We developed fluorescent amplification-based specific hybridization (FLASH-PCR) assay to detect the Stx-encoding gene Stx-1 of E. coli O157:H7. RESULT: PCR product of 336 bp was successfully amplified in a FLASH-PCR.
CONCLUSION: As rapid detection and confirmation of the presence of E. coli O157:H7 are of importance for the medical, food, and water industries, FLASH-PCR is one of selective methods for detection of E. coli O157:H7.

Entities:  

Keywords:  Detection; E.coli O157:H7; FLASH-PCR; Stx-1 gene

Year:  2012        PMID: 23115724      PMCID: PMC3482334     

Source DB:  PubMed          Journal:  Iran Red Crescent Med J        ISSN: 2074-1804            Impact factor:   0.611


Introduction

Escherichia coli O157: H7 is an enteric pathogen which can be frequently found asymptomatically in ruminant mammals, but can cause diseases from mild diarrhea to hemolytic uremic syndrome in humans. A small percentage of healthy cattle may normally harbor the organism and are considered to be the primary reservoir of E. coli O157: H7 associated with human disease, as a result of carcasses and hides becoming contaminated by feces during processing (1-3). Food products from other ruminants such as sheep and deer have also been found to be contaminated after processing (4). Potential food sources other than ground meet include unpasteurized juices, milk, dressings and foods such as vegetables that could be contaminated by manure, contaminated water or an infected food handler (2,5). In addition, another major reservoir of disease-causing E. coli O157:H7 can be water contaminated with feces, such as surface water runoff, irrigation water, insufficiently chlorinated municipal water, and swimming water (pools, lakes, beaches) (5). Molecular approaches for bacterial detection avoid the need for culture and can be designed to be specific. Many molecular-based E. coli assays have been developed. Several polymerase chain reaction (PCR) (6-8), reverse transcriptase PCR (RT-PCR) (9,10), and real-time PCR (11,12), tests have been developed to detect E. coliO157:H7. However, no test used currently detects the eae gene and make it possible to obtain confirmation of negative or positive test results in less than 12 h from the receipt of a sample. One of the simplest approaches to rapid and sensitive diagnosis and identification of pathogens using DNA technologies is a modification of PCR with the detection of fluorescence during the amplification (real-time PCR) or after its termination (PCR–FLASH) (13). The technique of fluorescent amplification-based specific hybridization (FLASH–PCR), based on determining PCR results by fluorescence intensity, was developed to improve the cost-efficiency of diagnostic laboratories by employing original economical high quality equipment and to eliminate the risk of working zone contamination (13,14). The aim of the present study was to identification of E. coli O157:H7 via the detection of Stx-encoding gene Stx-1 using FLASH-PCR.

Materials and Methods

Bacterial strains

Escherichia coli O157:H7 (ATCC 10798TM), Escherichia coli C str. (ATCC 8739), Escherichia coli (Migula) (ATCC 4351) and Escherichia coli (ATCC 25922TM) were originally obtained from American Type Culture Collection (ATCC), USA.

Oligonucleotide primers and Probe design

Primers specific for a conserved region situated within the E.coli Stx-1 gene were selected (Accession no. AB083044.1). Sequence alignment was performed using Mega 4 (alignment was done using Clustal W, and phylogenetic trees were constructed by neighbor joining) (15,16), and BLAST software (NCBI). Primers and fluorescently labeled probes were designed by primer design software (Primer Premier 5.0; Premier Biosoft Inc., Canada), and their secondary structure was examined with Gene Runner version 3.05 (Hastings Software Inc. Hastings, NY, USA, http://www.generunner.com). All oligonucleotides were synthesized by BIORON Company (Germany). The fluorescent reporter dye at the 5′ termini of the probe was 6-carboxyfluorescein (FAM), and a quencher of fluorescent was BHQ1 at the 3′ termini. A BLAST search of the GenBank database demonstrates a high predicted specificity, with the cross-reacting bacteria Escherichia coli C str. and Escherichia coli (Migula). To determine the analytical sensitivity of this assay, bacterial DNA for testing was prepared by using the Genomic DNA isolation Kit (GeNetBio, Korea) according to the manufacturer’s instructions. The DNA concentration was determined by measuring the optical density at 260 nm with the GeneQuant spectrophotometer (Pharmacia, Piscataway,N.J.). The DNA concentration was 3 (0.3) mg/ml. Serial dilutions of the extract were tested, and the described assay was able to detect 10 fg of DNA.

DNA Extraction and FLASH-PCR

DNA extracts were prepared from cultured organisms by using the Genomic DNA isolation Kit (GeNetBio) according to the manufacturer’s instructions. PCR was performed as suggested by standard manuals (17,18). A 25 μl volumes containing 2.5 μl of 10× PCR buffer (750 mM TrisHCl, pH 8.8, 200 mM ammonium sulfate, 0.1% Tween-20), 1 mM each of the four deoxynucleoside triphosphates, 3 mM MgCl2, 1 μl of template DNA, 12.5 pM of each primer, 25 pM probe and 2.5 U of Taq DNA polymerase (BIORON, Germany). The PCR amplifications were performed in a thermal cycler (DNA Technology,Russia) using the following cycling conditions: an initial denaturation at 94°C for 5 min and 30 cycles, with 1 cycle consisting of 30 s at 94°C, 50 s at 58°C for detection of Stx-1, 40 s at 70°C, followed by a final step 2 min at 70 °C, 1 min at 93°C, 1 min at 40°C, and 10 min at 20°C. FLASH analysis of PCR results was performed using a PCR-detector (DNA technology).

Electrophoresis

PCR products were separated by electrophoresis in 1% agarose gels in TAE (40 mM TrisHCl, 20 mM acetic acid, 1 mM EDTA) containing 0.5 μg/ml ethidium bromide and visualized using an Uvitec transilluminator (Gel Imager 2, Russia). The molecular weights were estimated using a Gene Ruler marker (DIALAT Ltd., Russia).

Results

Species-specific forward (EC-F) and reverse (EC-R) primers generated a PCR product of 336 bp (Table 1).
Table 1

Primers and probe for detection of E. coli O157:H7.

Target genePCR Product LengthPrimer & Probe Seq.ATCCCross-reaction
Stx-1336 bp F: 5´-GCGATGTTACGGTTTGTTACT-3´ R: 5´-ACGGACTCTTCCATCTGCC-3´10798TM1- Escherichia coli C str. ATCC 8739 2-Escherichia coli (Migula) ATCC 4351 3- Escherichia coli ATCC 25922™
Probe: 5´-FAM -ccctcgcttgccagaatggcatctgatggcgaggg-BHQ1-3´
The results of testing the samples using the FLASH format are expressed in (Fig. 1).
Fig.1

The results of samples by FLASH analysis.

A gel electrophoretic analysis of the test system for E.coli (Fig. 2) showed that, with the use of primers strictly specific for this pathogen, only the E.coli O157:H7 is clearly identified (lane 2), whereas the amplification with the DNAs of Escherichia coli C str. and Escherichia coli (Migula) give no amplicons (lanes 1 & 4).
Fig.2

The results of samples by gel electrophoresis. M. Marker, lane 1. E. coli O157:H7, 2. E.coli C. str, 3. E.coli (Migula), 4. E.coli, 5. Negative Control.

These results showed that during the elongation process in E.coli O157:H7 tube, DNA polymerase destroys the probe due to its 5′-exonuclease activity. This leads to the separation of the fluorophor and quencher and the enhanced fluorescence level.

Discussion

FLASH –PCR provides a useful approach for the detection of pathogens in environmental and other samples. Numerous researchers have studied and diagnosed E. coli O157: H7 using PCR on various samples, such as fecal samples from infected persons or contaminated food samples (raw milk or meat) suspected as causative of outbreak.(19, 20) The use of a single pair of primers specific to target genes that are characteristics of E. coli O157:H7, eg, vt eaeA EHEChlyA or uidA, is unable to give an unambiguous positive result as there are a variety of other gram-negative organisms possessing the same target genes of E. coli O157:H7 (21, 22). The visualization of the E.coli O157:H7 PCR product by electrophoresis is a laborious and time-consuming process, which inevitably leads upon large-scale screenings to the contamination by amplification products. In order to simplify and accelerate the procedure and avoid the problems associated with possible contamination, we modified the analysis of the results of PCR amplification and transferred it into the FLASH format. The fluorescence signal for FLASH-PCR of E. coli O157:H7 is 6.40 and the maximum fluorescence signal for FLASH-PCR of other related species is 2.50 (Fig 1). These results indicate that these primers and probe is specifics for E. coli O157:H7. This modified FLASH-PCR protocol has a potential to be used for rapid, sensitive and specific method in the specific detection of E. coli O157:H7.
  20 in total

1.  Rapid detection of Shiga toxin-producing bacteria in feces by multiplex PCR with molecular beacons on the smart cycler.

Authors:  Simon D Bélanger; Maurice Boissinot; Christian Ménard; François J Picard; Michel G Bergeron
Journal:  J Clin Microbiol       Date:  2002-04       Impact factor: 5.948

2.  Rapid detection of Escherichia coli O157:H7 with multiplex real-time PCR assays.

Authors:  Narayanan Jothikumar; Mansel W Griffiths
Journal:  Appl Environ Microbiol       Date:  2002-06       Impact factor: 4.792

Review 3.  An introduction to PCR techniques.

Authors:  Gill Rumsby
Journal:  Methods Mol Biol       Date:  2006

4.  Evaluation of culture- and PCR-based detection methods for Escherichia coli O157:H7 in inoculated ground beeft.

Authors:  Terrance M Arthur; Joseph M Bosilevac; Xiangwu Nou; Mohammad Koohmaraie
Journal:  J Food Prot       Date:  2005-08       Impact factor: 2.077

5.  Detection of Escherichia coli O157:H7 in soil and water using multiplex PCR.

Authors:  G R Campbell; J Prosser; A Glover; K Killham
Journal:  J Appl Microbiol       Date:  2001-12       Impact factor: 3.772

6.  Rapid and specific identification of Shiga toxin-producing Escherichia coli in faeces by multiplex PCR.

Authors:  J Osek
Journal:  Lett Appl Microbiol       Date:  2002       Impact factor: 2.858

7.  A reverse transcriptase-polymerase chain reaction assay for detection of viable Escherichia coli O157:H7: investigation of specific target genes.

Authors:  S Yaron; K R Matthews
Journal:  J Appl Microbiol       Date:  2002       Impact factor: 3.772

8.  Persistence of enterohemorrhagic Escherichia coli O157:H7 in soil and on leaf lettuce and parsley grown in fields treated with contaminated manure composts or irrigation water.

Authors:  Mahbub Islam; Michael P Doyle; Sharad C Phatak; Patricia Millner; Xiuping Jiang
Journal:  J Food Prot       Date:  2004-07       Impact factor: 2.077

9.  Characterization of O157:H7 and other Escherichia coli isolates recovered from cattle hides, feces, and carcasses.

Authors:  Genevieve A Barkocy-Gallagher; Teerrance M Arthur; Mildred Rivera-Betancourt; Xiangwu Nou; Steven D Shackelford; Tommy L Wheeler; Mohammad Koohmaraie
Journal:  J Food Prot       Date:  2004-05       Impact factor: 2.077

10.  Rectal administration of Escherichia coli O157:H7: novel model for colonization of ruminants.

Authors:  Haiqing Sheng; Margaret A Davis; Hannah J Knecht; Carolyn J Hovde
Journal:  Appl Environ Microbiol       Date:  2004-08       Impact factor: 4.792

View more
  1 in total

Review 1.  A review on detection methods used for foodborne pathogens.

Authors:  B Priyanka; Rajashekhar K Patil; Sulatha Dwarakanath
Journal:  Indian J Med Res       Date:  2016-09       Impact factor: 2.375

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.