Physiologic trend detection and artifact rejection: a parallel implementation of a multi-state Kalman filtering algorithm.

D F Sittig1, M Factor.   

Abstract

Using a parallel implementation of the multi-state Kalman filtering algorithm, we have developed an accurate method of reliably detecting and identifying trends, abrupt changes, and artifacts from multiple physiologic data streams in real-time. The Kalman filter algorithm was implemented within an innovative software architecture for parallel computation: a parallel process trellis. Examples, processed in real-time, of both simulated and actual data serve to illustrate the potential value of the Kalman filter as a tool in physiologic monitoring.

Mesh:

Year:  1990        PMID: 2311364     DOI: 10.1016/0169-2607(90)90026-6

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  8 in total

1.  Artifact detection in cardiovascular time series monitoring data from preterm infants.

Authors:  C Cao; I S Kohane; N McIntosh
Journal:  Proc AMIA Symp       Date:  1999

2.  Evaluation of a parallel implementation of the learning portion of the backward error propagation neural network: experiments in artifact identification.

Authors:  D F Sittig; J A Orr
Journal:  Proc Annu Symp Comput Appl Med Care       Date:  1991

3.  An approach to intelligent ischaemia monitoring.

Authors:  A Bosnjak; G Bevilacqua; G Passariello; F Mora; B Sansó; G Carrault
Journal:  Med Biol Eng Comput       Date:  1995-11       Impact factor: 2.602

4.  Artifact detection in the PO2 and PCO2 time series monitoring data from preterm infants.

Authors:  C Cao; N McIntosh; I S Kohane; K Wang
Journal:  J Clin Monit Comput       Date:  1999-08       Impact factor: 2.502

5.  Reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform.

Authors:  Anton Aboukhalil; Larry Nielsen; Mohammed Saeed; Roger G Mark; Gari D Clifford
Journal:  J Biomed Inform       Date:  2008-03-21       Impact factor: 6.317

6.  Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter.

Authors:  Q Li; R G Mark; G D Clifford
Journal:  Physiol Meas       Date:  2007-12-10       Impact factor: 2.833

7.  Machine Learning and Decision Support in Critical Care.

Authors:  Alistair E W Johnson; Mohammad M Ghassemi; Shamim Nemati; Katherine E Niehaus; David A Clifton; Gari D Clifford
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2016-01-25       Impact factor: 10.961

8.  Real-Time Arrhythmia Detection Using Hybrid Convolutional Neural Networks.

Authors:  Sandeep Chandra Bollepalli; Rahul K Sevakula; Wan-Tai M Au-Yeung; Mohamad B Kassab; Faisal M Merchant; George Bazoukis; Richard Boyer; Eric M Isselbacher; Antonis A Armoundas
Journal:  J Am Heart Assoc       Date:  2021-12-02       Impact factor: 6.106

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.